-
Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer
Authors:
Alicia M. Anderson,
David A. Naylor,
Brad G. Gom,
Matthew A. Buchan,
Adam J. Christiansen,
Ian T. Veenendaal
Abstract:
Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features refle…
▽ More
Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting diffraction gratings which post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This paper discusses the development of a cryogenic (4 K) diffraction grating spectrometer which operates over the wavelength range from 285 - 500 $μ$m and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance.
△ Less
Submitted 30 January, 2024; v1 submitted 9 January, 2024;
originally announced January 2024.
-
Inference and Prediction Using Functional Principal Components Analysis: Application to Diabetic Kidney Disease Progression in the Chronic Renal Insufficiency Cohort (CRIC) Study
Authors:
Brian Kwan,
Wei Yang,
Daniel Montemayor,
**g Zhang,
Tobias Fuhrer,
Amanda H. Anderson,
Cheryl A. M. Anderson,
**g Chen,
Ana C. Ricardo,
Sylvia E. Rosas,
Loki Natarajan,
the CRIC Study Investigators
Abstract:
Repeated longitudinal measurements are commonly used to model long-term disease progression, and timing and number of assessments per patient may vary, leading to irregularly spaced and sparse data. Longitudinal trajectories may exhibit curvilinear patterns, in which mixed linear regression methods may fail to capture true trends in the data. We applied functional principal components analysis to…
▽ More
Repeated longitudinal measurements are commonly used to model long-term disease progression, and timing and number of assessments per patient may vary, leading to irregularly spaced and sparse data. Longitudinal trajectories may exhibit curvilinear patterns, in which mixed linear regression methods may fail to capture true trends in the data. We applied functional principal components analysis to model kidney disease progression via estimated glomerular filtration rate (eGFR) trajectories. In a cohort of 2641 participants with diabetes and up to 15 years of annual follow-up from the Chronic Renal Insufficiency Cohort (CRIC) study, we detected novel dominant modes of variation and patterns of diabetic kidney disease (DKD) progression among subgroups defined by the presence of albuminuria. We conducted inferential permutation tests to assess differences in longitudinal eGFR patterns between groups. To determine whether fitting a full cohort model or separate group-specific models is more optimal for modeling long-term trajectories, we evaluated model fit, using our goodness-of-fit procedure, and future prediction accuracy. Our findings indicated advantages for both modeling approaches in accomplishing different objectives. Beyond DKD, the methods described are applicable to other settings with longitudinally assessed biomarkers as indicators of disease progression. Supplementary materials for this article are available online.
△ Less
Submitted 20 October, 2022;
originally announced October 2022.
-
Formation of Chimneys in Mushy Layers: Experiment and Simulation
Authors:
Anthony M. Anderson,
Richard F. Katz,
Grae Worster
Abstract:
In this fluid dyanmics video, we show experimental images and simulations of chimney formation in mushy layers. A directional solidification apparatus was used to freeze 25 wt % aqueous ammonium chloride solutions at controlled rates in a narrow Hele-Shaw cell (1mm gap). The convective motion is imaged with schlieren. We demonstrate the ability to numerically simulate mushy layer growth for direct…
▽ More
In this fluid dyanmics video, we show experimental images and simulations of chimney formation in mushy layers. A directional solidification apparatus was used to freeze 25 wt % aqueous ammonium chloride solutions at controlled rates in a narrow Hele-Shaw cell (1mm gap). The convective motion is imaged with schlieren. We demonstrate the ability to numerically simulate mushy layer growth for direct comparison with experiments.
△ Less
Submitted 18 October, 2011;
originally announced October 2011.