-
In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
A. Breskin,
A. E. C. Coimbra,
E. Oliveri,
F. A. Pereira,
D. Shaked Renous,
J. Schaarschmidt,
J. M. F. dos Santos,
J. F. C. A. Veloso,
S. Bressler
Abstract:
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low aver…
▽ More
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
△ Less
Submitted 8 September, 2016; v1 submitted 9 July, 2016;
originally announced July 2016.
-
DARWIN: towards the ultimate dark matter detector
Authors:
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
C. Amsler,
E. Aprile,
L. Arazi,
F. Arneodo,
P. Barrow,
L. Baudis,
M. L. Benabderrahmane,
T. Berger,
B. Beskers,
A. Breskin,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. Calven,
J. M. R. Cardoso,
D. Cichon,
D. Coderre
, et al. (94 additional authors not shown)
Abstract:
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible…
▽ More
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well as measure the low-energy solar neutrino flux with <1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R&D efforts.
△ Less
Submitted 22 June, 2016;
originally announced June 2016.
-
A low-mass dark matter search using ionization signals in XENON100
Authors:
XENON100 Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown S. Bruenner,
G. Bruno,
R. Budnik,
A. Buss,
L. Bütikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (86 additional authors not shown)
Abstract:
We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By drop** the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be…
▽ More
We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By drop** the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\% confidence level.
△ Less
Submitted 19 December, 2016; v1 submitted 20 May, 2016;
originally announced May 2016.
-
The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
Authors:
L. Moleri,
F. D. Amaro,
L. Arazi,
C. D. R. Azevedo,
E. Oliveri,
M. Pitt,
J. Schaarschmidt,
D. Shaked-Renous,
J. M. F. dos Santos,
J. F. C. A. Veloso,
A. Breskin,
S. Bressler
Abstract:
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistiv…
▽ More
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9$Ωcm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, drop** by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
△ Less
Submitted 15 March, 2016;
originally announced March 2016.
-
Physics reach of the XENON1T dark matter experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
L. Arazi,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
T. Berger,
P. Breur,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon
, et al. (91 additional authors not shown)
Abstract:
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and (…
▽ More
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_χ$=$50$ GeV/$c^2$.
△ Less
Submitted 15 April, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
First in-beam studies of a Resistive-Plate WELL gaseous multiplier
Authors:
S. Bressler,
L. Moleri,
M. Pitt,
S. Kudella,
D. C. R. Azevedo,
F. D. Amaro,
M. R. Jorge,
J. M. F. dos Santos,
J. F. C. A. Veloso,
H. Natal da Luz,
L. Arazi,
E. Olivieri,
A. Breskin
Abstract:
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ squar…
▽ More
We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 Ω$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.
△ Less
Submitted 20 January, 2016; v1 submitted 11 October, 2015;
originally announced October 2015.
-
Experiments towards resolving the proton charge radius puzzle
Authors:
A. Antognini,
K. Schuhmann,
F. D. Amaro,
P. Amaro,
M. Abdou-Ahmed,
F. Biraben,
T. -L. Chen,
D. S. Covita,
A. J. Dax,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. L. Gouvea,
J. Götzfried,
T. Graf,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien,
K. Kirch,
A. Knecht,
F. Kottmann,
J. J. Krauth,
Y. -W. Liu
, et al. (12 additional authors not shown)
Abstract:
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
△ Less
Submitted 17 October, 2015; v1 submitted 10 September, 2015;
originally announced September 2015.
-
Improved X-ray detection and particle identification with avalanche photodiodes
Authors:
Marc Diepold,
Luis M. P. Fernandes,
Jorge Machado,
Pedro Amaro,
Marwan Abdou-Ahmed,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth,
Yi-Wei Liu
, et al. (14 additional authors not shown)
Abstract:
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to acco…
▽ More
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g. to distinguish between x-rays and MeV electrons in our experiment.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
Lifetime and population of the 2S state in muonic protium and deuterium
Authors:
Marc Diepold,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
João M. R. Cardoso,
Daniel S. Covita,
Andreas Dax,
Satish Dhawan,
Luis M. P. Fernandes,
Adolf Giesen,
Andrea L. Gouvea,
Thomas Graf,
Theodor W. Hänsch,
Paul Indelicato,
Lucile Julien,
Cheng-Yang Kao,
Paul Knowles,
Franz Kottmann,
Eric-Olivier Le Bigot,
Yi-Wei Liu,
José A. M. Lopes,
Livia Ludhova,
Cristina M. B. Monteiro,
Françoise Mulhauser,
Tobias Nebel
, et al. (10 additional authors not shown)
Abstract:
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The sho…
▽ More
Radiative deexcitation (RD) of the metastable 2S state of muonic protium and deuterium atoms has been observed. In muonic protium, we improve the precision on lifetime and population (formation probability) values for the short-lived μp(2S) component, and give an upper limit for RD of long-lived μp(2S) atoms. In muonic deuterium at 1 hPa, 3.1 +-0.3 % of all stopped muons form μd(2S) atoms. The short-lived 2S component has a population of 1.35 +0.57 -0.33 % and a lifetime of τ_short(μd) = 138 +32 -34 ns. We see evidence for RD of long-lived μd(2S) with a lifetime of τ_long(μd) = 1.15 +0.75 -0.53 μs. This is interpreted as formation and decay of excited muonic molecules.
△ Less
Submitted 10 October, 2013; v1 submitted 25 July, 2013;
originally announced July 2013.
-
Characterization of the Hamamatsu S8664 Avalanche Photodiode for X-Ray and VUV-light detection
Authors:
T. Lux,
E. D. C. Freitas,
F. D. Amaro,
O. Ballester,
G. V. Jover-Manas,
C. Martin,
C. M. B. Monteiro,
F. Sanchez,
J. Rico
Abstract:
We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD bias voltage it was of about 30 % for 22.1 keV and about 45 % for 5.9 keV. The quantum efficiency for 172 nm photons has been measured to be 69 +/- 15 %.
We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD bias voltage it was of about 30 % for 22.1 keV and about 45 % for 5.9 keV. The quantum efficiency for 172 nm photons has been measured to be 69 +/- 15 %.
△ Less
Submitted 5 January, 2012; v1 submitted 25 August, 2011;
originally announced August 2011.
-
Pionic deuterium
Authors:
Th. Strauch,
F. D. Amaro,
D. Anagnostopoulos,
P. Bühler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. Le Bigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
S. Schlesser,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The strong interaction shift $ε$ and broadening Γ in pionic deuterium have been determined in a high statistics study of the πD(3p - 1s) X-ray transition using a high-resolution crystal spectrometer. The pionic deuterium shift will provide constraints for the pion-nucleon isospin scattering lengths extracted from measurements of shift and broadening in pionic hydrogen. The hadronic broadening is r…
▽ More
The strong interaction shift $ε$ and broadening Γ in pionic deuterium have been determined in a high statistics study of the πD(3p - 1s) X-ray transition using a high-resolution crystal spectrometer. The pionic deuterium shift will provide constraints for the pion-nucleon isospin scattering lengths extracted from measurements of shift and broadening in pionic hydrogen. The hadronic broadening is related to pion absorption and production at threshold. The results are ε= (-2356 {\pm} 31)meV (repulsive) and Γ1s = (1171+23/-49) meV yielding for the complex πD scattering length a = [-(24.99 {\pm} 0.33) + i (6.22+0.12/-0.26)]x10-3/mπ. From the imaginary part, the threshold parameter for pion production is obtained to be α = (251 +5/-11) μb. This allows, in addition, and by using results from pion absorption in 3He at threshold, the determination of the effective couplings g0 and g1 for s-wave pion absorption on isoscalar and isovector NN pairs.
△ Less
Submitted 12 July, 2011; v1 submitted 10 November, 2010;
originally announced November 2010.
-
The Thick-COBRA: a New Gaseous Electron Multiplier for Radiation Detectors
Authors:
F. D. Amaro,
C. Santos,
J. F. C. A. Veloso,
A. Breskin,
R. Chechik,
J. M. F. dos Santos
Abstract:
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between…
▽ More
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne and Ar-10%CH4, with 12.2 % FWHM energy resolution in Ar-10%CH4. Higher gains were measured with single photoelectrons. This robust multiplier may have numerous potential applications.
△ Less
Submitted 4 August, 2010;
originally announced August 2010.
-
Precision determination of the dpi -> NN transition strength at threshold
Authors:
Th. Strauch,
F. D. Amaro,
D. F. Anagnostopoulos,
P. Bühler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. LeBigot,
M. Nekipelov,
J. M. F. dos Santos,
S. Schlesser,
Ph. Schmid,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
An unusual but effective way to determine at threshold the dpi -> NN transition strength is to exploit the hadronic ground-state broadening in pionic deuterium, accessible by x-ray spectroscopy. The broadening is dominated by the true absorption channel dpi- -> nn, which is related to s-wave pion production pp -> dpi+ by charge symmetry and detailed balance. Using the exotic atom circumvents the…
▽ More
An unusual but effective way to determine at threshold the dpi -> NN transition strength is to exploit the hadronic ground-state broadening in pionic deuterium, accessible by x-ray spectroscopy. The broadening is dominated by the true absorption channel dpi- -> nn, which is related to s-wave pion production pp -> dpi+ by charge symmetry and detailed balance. Using the exotic atom circumvents the problem of Coulomb corrections to the cross section as necessary in the production experiments. Our dedicated measurement finds (1171+23/-49) meV for the broadening yielding (252+5/-11) \mub.
△ Less
Submitted 22 March, 2010;
originally announced March 2010.
-
Pionic Deuterium
Authors:
Th. Strauch,
F. D. Amaro,
D. F. Anagnostopoulos,
P. B"\uhler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. Le Bigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
S. Schlesser,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The strong interaction shift and broadening in pionic deuterium have been remeasured with high statistics by means of the (3p-1s) X-ray transition using the cyclotron trap and a high-resolution crystal spectrometer. Preliminary results are (-2325+/-31) meV (repulsive) for the shift and (1171+23/-49} meV for the width, which yields precise values for the pion-deuteron scattering length and the th…
▽ More
The strong interaction shift and broadening in pionic deuterium have been remeasured with high statistics by means of the (3p-1s) X-ray transition using the cyclotron trap and a high-resolution crystal spectrometer. Preliminary results are (-2325+/-31) meV (repulsive) for the shift and (1171+23/-49} meV for the width, which yields precise values for the pion-deuteron scattering length and the threshold parameter for pion production.
△ Less
Submitted 23 February, 2010;
originally announced February 2010.
-
Development of high-gain gaseous photomultipliers for the visible spectral range
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. M. F. Dos Santos,
F. D. Amaro,
J. F. C. A. Veloso
Abstract:
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the elec…
▽ More
We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and a record ion blocking capability. We describe in details the system and methods of photocathode production and characterization, their coupling with the electron multiplier and the gaseous-photomultiplier operation and characterization in a continuous mode. We present results on the properties of laboratory-produced K$_2$CsSb, Cs$_3$Sb and Na$_2$KSb photocathodes and report on their stability and QE in gas; K$_2$CsSb photocathodes yielded QE values in Ar/CH$_4$(95/5) above 30% at wavelengths of 360-400 nm. The novel gaseous photomultiplier yielded stable operation at gains of 10$^5$, in continuous operation mode, in 700 Torr of this gas; its sensitivity to single photons was demonstrated. Other properties are described. The successful detection of visible light with this gas-photomultiplier pave ways towards further development of large-area sealed imaging detectors, of flat geometry, insensitive to magnetic fields, which might have significant impact on light detection in numerous fields.
△ Less
Submitted 5 May, 2009; v1 submitted 1 May, 2009;
originally announced May 2009.
-
High-gain DC-mode operated Gaseous Photomultipliers for the visible spectral range
Authors:
A. Lyashenko,
A. Breskin,
R. Chechik,
F. D. Amaro,
J. Veloso,
J. M. F. Dos Santos
Abstract:
We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.
We shortly describe recent progress in photon detectors combining bi-alkali photocathodes and cascaded patterned gas-avalanche electron multipliers. It permitted the development and the first feasibility demonstration of high-gain gaseous photomultipliers sensitive in the visible spectral range, operated in DC mode with single-photon sensitivity.
△ Less
Submitted 12 August, 2008; v1 submitted 11 August, 2008;
originally announced August 2008.
-
High pressure operation of the Photon-Assisted Cascaded Electron Multiplier
Authors:
F. D. Amaro,
J. F. C. A. Veloso,
J. M. F. dos Santos,
A. Breskin,
R. Chechik,
A. Lyashenko
Abstract:
We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron avalanches is used for signal propagation: the VUV scintillation produced in the first element of the cascade induces the emission of photoelectrons from a CsI photoca…
▽ More
We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron avalanches is used for signal propagation: the VUV scintillation produced in the first element of the cascade induces the emission of photoelectrons from a CsI photocathode placed on the top-surface of the second element. These photoelectrons are further multiplied, via charge avalanche. A metallic mesh electrode placed between the first and the second elements of the cascade completely blocks the charge transfer between them. Optical gains of 103 were achieved in xenon at atmospheric pressure, drop** to 25 at 3.3 bar, for applied voltages of 700 and 1100 V, respectively. Taking into account the subsequent charge multiplication, total gains are higher than those obtained with a triple GEM and double THGEM.
△ Less
Submitted 31 July, 2008;
originally announced July 2008.
-
Efficient ion blocking in gaseous detectors and its application to gas-avalanche photomultipliers sensitive in the visible-light range
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. M. F. Dos Santos,
F. D. Amaro,
J. F. C. A. Veloso
Abstract:
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in operation conditions adequate for TPCs and for gaseous photomultipliers. The concept was validated in a cascaded visible-sensitive gas avalanche photomultiplier…
▽ More
A novel concept for ion blocking in gas-avalanche detectors was developed, comprising cascaded micro-hole electron multipliers with patterned electrodes for ion defocusing. This leads to ion blocking at the 10^{-4} level, in DC mode, in operation conditions adequate for TPCs and for gaseous photomultipliers. The concept was validated in a cascaded visible-sensitive gas avalanche photomultiplier operating at atmospheric pressure of Ar/CH_{4} (95/5) with a bi-alkali photocathode. While in previous works high gain, in excess of 10^{5}, was reached only in a pulse-gated cascaded-GEM gaseous photomultiplier, the present device yielded, for the first time, similar gain in DC mode. We describe shortly the physical processes involved in the charge transport within gaseous photomultipliers and the ion blocking method. We present results of ion backflow fraction and of electron multiplication in cascaded patterned-electrode gaseous photomultiplier with K-Cs-Sb, Na-K-Sb and Cs-Sb visible-sensitive photocathodes, operated in DC mode.
△ Less
Submitted 28 April, 2008;
originally announced April 2008.
-
Further progress in ion back-flow reduction with patterned gaseous hole-multipliers
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. F. C. A. Veloso,
J. M. F. Dos Santos,
F. D. Amaro
Abstract:
A new idea on electrostatic deviation and capture of back-drifting avalanche-ions in cascaded gaseous hole-multipliers is presented. It involves a flipped reversed-bias Micro-Hole & Strip Plate (F-R-MHSP) element, the strips of which are facing the drift region of the multiplier. The ions, originating from successive multiplication stages, are efficiently deviated and captured by such electrode.…
▽ More
A new idea on electrostatic deviation and capture of back-drifting avalanche-ions in cascaded gaseous hole-multipliers is presented. It involves a flipped reversed-bias Micro-Hole & Strip Plate (F-R-MHSP) element, the strips of which are facing the drift region of the multiplier. The ions, originating from successive multiplication stages, are efficiently deviated and captured by such electrode. Experimental results are provided comparing the ion-blocking capability of the F-R-MHSP to that of the reversed-bias Micro-Hole & Strip Plate (R-MHSP) and the Gas Electron Multiplier (GEM). Best ion-blocking results in cascaded hole-multipliers were reached with a detector having the F-R-MHSP as the first multiplication element. A three-element F-R-MHSP/GEM/MHSP cascaded multiplier operated in atmospheric-pressure Ar/CH4 (95/5), at total gain of ~10^{5}, yielded ion back-flow fractions of 3*10^{-4} and 1.5*10^{-4}, at drift fields of 0.5 and 0.2 kV/cm, respectively. We describe the F-R-MHSP concept and the relevance of the obtained ion back-flow fractions to various applications; further ideas are also discussed.
△ Less
Submitted 14 August, 2007; v1 submitted 25 June, 2007;
originally announced June 2007.
-
Characterization of large area avalanche photodiodes in X-ray and VUV-light detection
Authors:
L. M. P. Fernandes,
F. D. Amaro,
A. Antognini,
J. M. R. Cardoso,
C. A. N. Conde,
O. Huot,
P. E. Knowles,
F. Kottmann,
J. A. M. Lopes,
L. Ludhova,
C. M. B. Monteiro,
F. Mulhauser,
R. Pohl,
J. M. F. dos Santos,
L. A. Schaller,
D. Taqqu,
J. F. C. A. Veloso
Abstract:
The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was…
▽ More
The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.
△ Less
Submitted 15 February, 2007;
originally announced February 2007.
-
Muonic hydrogen cascade time and lifetime of the short-lived $2S$ state
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Haensch,
V. W. Hughes,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
Y. -W. Liu,
J. A. M. Lopes,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos,
L. A. Schaller,
C. Schwob
, et al. (2 additional authors not shown)
Abstract:
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 h…
▽ More
Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $μp$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $μp ({2S})$ component was measured at 0.6 hPa $\mathrm{H}_2$ room temperature gas pressure, with lifetime $τ_{2S}^\mathrm{short} = 165 ^{+38}_{-29}$ ns (i.e., $λ_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1}$ at liquid-hydrogen density) and population $ε_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56}$ % (per $μp$ atom). In addition, a value of the $μp$ cascade time, $T_\mathrm{cas}^{μp} = (37\pm5)$ ns, was found.
△ Less
Submitted 13 November, 2006;
originally announced November 2006.
-
Advances in ion back-flow reduction in cascaded gaseous electron multipliers incorporating R-MHSP elements
Authors:
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. F. C. A. Veloso,
J. M. F. Dos Santos,
F. D. Amaro
Abstract:
A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of magnitude reduction in ion back-flow is achieved by diverting back-drifting ions from their original path. A R-MHSP/2GEM/MHSP cascaded multiplier operated at total ga…
▽ More
A new concept is presented for the reduction of ion back-flow in GEM-based cascaded gaseous electron multipliers, by incorporating Micro-Hole & Strip Plate (MHSP) elements operating in reversed-bias mode (R-MHSP). About an order of magnitude reduction in ion back-flow is achieved by diverting back-drifting ions from their original path. A R-MHSP/2GEM/MHSP cascaded multiplier operated at total gain of ~1.5*10^5 yielded ion back-flow fractions of 0.0015 and 0.0004, at drift fields of 0.5 and 0.1 kV/cm, respectively. A 2R-MHSP/MHSP cascaded multiplier operated at a total gain of ~10^5, yielded an ion back-flow fraction of 0.003. We discuss the concept for trap** back-flowing ions in these cascaded multipliers and the relevance to gaseous photomultiplier and TPC applications; directions for further future developments are outlined.
△ Less
Submitted 3 July, 2006;
originally announced July 2006.
-
The Photon-Assisted Cascaded Electron Multiplier: a Concept for Potential Avalanche-Ion Blocking
Authors:
J. F. C. A. Veloso,
F. D. Amaro,
J. M. F. dos Santos,
A. Breskin,
A. Lyashenko,
R. Chechik
Abstract:
We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its photons, which in turn induce photoelectron emission from a photocathode deposited on the second multiplier stage; the multiplication process may further continu…
▽ More
We present a Photon-Assisted Cascaded Electron Multipliers (PACEM) which has a potential for ion back-flow blocking in gaseous radiation detectors: the avalanche from a first multiplication stage propagates to the successive one via its photons, which in turn induce photoelectron emission from a photocathode deposited on the second multiplier stage; the multiplication process may further continue via electron-avalanche propagation. The photon-mediated stage allows, by a proper choice of geometry and fields, complete blocking of the ion back-flow into the first element; thus, only ions from the latter will flow back to the drift region. The PACEM concept was validated in a double-MHSP (Micro-Hole & Strip Plate) cascaded multiplier operated in xenon, where the intermediate scintillation stage provided optical gain of ~60. The double-MHSP detector had a total gain above 10^4 and energy resolution of 18% FWHM for 5.9 keV x-rays.
△ Less
Submitted 25 June, 2006;
originally announced June 2006.
-
Operation of MHSP multipliers in high pressure pure noble-gas
Authors:
F. D. Amaro,
J. F. C. A. Veloso,
A. Breskin,
R. Chechik,
J. M. F. dos Santos
Abstract:
We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they drop by about one order of magnitude at 2 bar and by almost another order of magnitude at 5-6 bar; they reach gains of 500 and 4000 at 5 bar in Xe and Kr, respec…
▽ More
We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they drop by about one order of magnitude at 2 bar and by almost another order of magnitude at 5-6 bar; they reach gains of 500 and 4000 at 5 bar in Xe and Kr, respectively. In Ar, the gain varies very little with pressure, being 3000-9000; in Ne the maximum attainable gain, about 100000, is pressure independent above 2 bar. The results are compared with that of single- and triple-GEM multipliers operated in similar conditions. Potential applications are in hard X-ray imaging and in cryogenic radiation detectors.
△ Less
Submitted 17 January, 2006;
originally announced January 2006.
-
MHSP in reversed-biased operation mode for ion blocking in gas-avalanche multipliers
Authors:
J. F. C. A. Veloso,
F. Amaro,
J. M. Maia,
A. V. Lyashenko,
A. Breskin,
R. Chechik,
J. M. F. dos Santos,
O. Bouianov,
M. Bouianov
Abstract:
We present recent results on the operation of gas-avalanche detectors comprising a cascade of gas electron multipliers (GEMs) and Micro-Hole and Strip Plates (MHSPs) multiplier operated in reversed-bias (R-MHSP) mode. The operation mechanism of the R-MHSP is explained and its potential contribution to ion-backflow (IBF) reduction is demonstrated. IBF values of 4E-3 were obtained in cascaded R-MH…
▽ More
We present recent results on the operation of gas-avalanche detectors comprising a cascade of gas electron multipliers (GEMs) and Micro-Hole and Strip Plates (MHSPs) multiplier operated in reversed-bias (R-MHSP) mode. The operation mechanism of the R-MHSP is explained and its potential contribution to ion-backflow (IBF) reduction is demonstrated. IBF values of 4E-3 were obtained in cascaded R-MHSP and GEM multipliers at gains of about 1E+4, though at the expense of reduced effective gain in the first R- MHSP multiplier in the cascade.
△ Less
Submitted 31 March, 2005;
originally announced March 2005.
-
Ion-induced effects in GEM & GEM/MHSP gaseous photomultipliers for the UV and the visible spectral range
Authors:
A. Breskin,
D. Mormann,
A. Lyashenko,
R. Chechik,
F. D. Amaro,
J. M. Maia,
J. F. C. A. Veloso,
J. M. F. dos Santos
Abstract:
We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of part…
▽ More
We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of particular importance are the results of a recent ion-backflow reduction study in different cascaded multipliers, affecting the detector's stability and the photocathode's liftime. We report on the significant progress in ion-blocking and provide first results on bialkali-photocathode aging under gas multiplication.
△ Less
Submitted 24 February, 2005;
originally announced February 2005.
-
Planar LAAPDs: Temperature Dependence, Performance, and Application in Low Energy X-ray Spectroscopy
Authors:
L. Ludhova,
F. D. Amaro,
A. Antognini,
F. Biraben,
J. M. R. Cardoso,
C. A. N. Conde,
D. S. Covita,
A. Dax,
S. Dhawan,
L. M. P. Fernandes,
T. W. Hansch,
V. W. Hughes,
O. Huot,
P. Indelicato,
L. Julien,
P. E. Knowles,
F. Kottmann,
J. A. M. Lopes,
Y. -W. Liu,
C. M. B. Monteiro,
F. Mulhauser,
F. Nez,
R. Pohl,
P. Rabinowitz,
J. M. F. dos Santos
, et al. (3 additional authors not shown)
Abstract:
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanc…
▽ More
An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as x-ray detectors, and they were used during the last data taking period in 2003. For x-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise, hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to alpha particles are presented.
△ Less
Submitted 15 October, 2004;
originally announced October 2004.