Zero-echo-time sequences in highly inhomogeneous fields
Authors:
Jose Borreguero,
Fernando Galve,
José Miguel Algarín,
Joseba Alonso
Abstract:
Zero echo time (ZTE) sequences have proven a powerful tool for Magnetic Resonance Imaging (MRI) of ultrashort T2 tissues, but they fail to produce useful images in the presence of strong field inhomogeneities. Here we present a method to correct artifacts induced by strong B0 inhomogeneities in non-Cartesian sequences, based on magnetic field maps obtained from the phase difference between two fas…
▽ More
Zero echo time (ZTE) sequences have proven a powerful tool for Magnetic Resonance Imaging (MRI) of ultrashort T2 tissues, but they fail to produce useful images in the presence of strong field inhomogeneities. Here we present a method to correct artifacts induced by strong B0 inhomogeneities in non-Cartesian sequences, based on magnetic field maps obtained from the phase difference between two fast pointwise acquisitions. These are free of geometric distortions and can be used for model based image reconstruction with iterative algebraic techniques. In this paper, we show that distortions and artifacts coming from inhomogeneites in B0 are largely reverted by our method, as opposed to standard Conjugate Phase reconstructions. We base this technique on a Single-Point Double-Shot (SPDS) approach, and we have shown it to work even for intra-voxel bandwidths (determined by B0 inhomogeneities) comparable to the encoding bandwidth (determined by the gradient fields). We benchmark the performance of SPDS for ZTE acquisitions, which can be exploited for e.g. dental imaging in affordable low-field MRI systems. Furthermore, SPDS can be used for arbitrary pulse sequences and it may prove useful for extreme magnet geometries, as in e.g. single-sided MRI.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
Elliptical Halbach magnet and gradient modules for low-field portable MRI
Authors:
Fernando Galve,
Eduardo Pallás,
Teresa Guallart-Naval,
Pablo García-Cristóbal,
Pablo Martínez,
José M. Algarín,
José Borreguero,
Rubén Bosch,
Francisco Juan-Lloris,
José M. Benlloch,
Joseba Alonso
Abstract:
Objective. To develop methods to design the complete magnetic system for a truly portable MRI scanner for neurological and musculoskeletal (MSK) applications, optimized for field homogeneity, field of view (FoV) and gradient performance compared to existing low-weight configurations. Approach. We explore optimal elliptic-bore Halbach configurations based on discrete arrays of permanent magnets. In…
▽ More
Objective. To develop methods to design the complete magnetic system for a truly portable MRI scanner for neurological and musculoskeletal (MSK) applications, optimized for field homogeneity, field of view (FoV) and gradient performance compared to existing low-weight configurations. Approach. We explore optimal elliptic-bore Halbach configurations based on discrete arrays of permanent magnets. In this way, we seek to improve the field homogeneity and remove constraints to the extent of the gradient coils typical of Halbach magnets. Specifically, we have optimized a tightly-packed distribution of magnetic Nd$_2$Fe$_14$B cubes with differential evolution algorithms, and a second array of shimming magnets with interior point and differential evolution methods. We have also designed and constructed an elliptical set of gradient coils that extend over the whole magnet length, maximizing the distance between the lobe centers. These are optimized with a target field method minimizing a cost function that considers also heat dissipation. Main result. We have employed the new toolbox to build the main magnet and gradient modules for a portable MRI scanner designed for point-of-care and residential use. The elliptical Halbach bore has semi-axes of 10 & 14 cm and the magnet generates a field of 87 mT homogeneous down to 5,700 ppm (parts per million) in a 20 cm diameter FoV, it weighs 216 kg and has a width of 65 cm and a height of 72 cm. Gradient efficiencies go up to around 0.8 mT/m/A, for a maximum of 12 mT/m with in 0.5 ms with 15 A & 15 V amplifier. The distance between lobes is 28 cm, significantly increased with respect to other Halbach-based scanners. Heat dissipation is around 25 W at maximum power, and gradient deviations from linearity are below 20% in a 20 cm sphere.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
MaRGA: a Graphical and Application Interface for MaRCoS
Authors:
J. M. Algarín,
T. Guallart-Naval,
J. Borreguero,
F. Galve,
J. Alonso
Abstract:
The open-source console MaRCoS, which stands for "Magnetic Resonance Control System", combines hardware, firmware and software elements for integral control of Magnetic Resonance Imaging (MRI) scanners. Previous developments have focused on making the system robust and reliable, rather than on users, who have been somewhat overlooked. This work describes a Graphical User Interface (GUI) designed f…
▽ More
The open-source console MaRCoS, which stands for "Magnetic Resonance Control System", combines hardware, firmware and software elements for integral control of Magnetic Resonance Imaging (MRI) scanners. Previous developments have focused on making the system robust and reliable, rather than on users, who have been somewhat overlooked. This work describes a Graphical User Interface (GUI) designed for intuitive control of MaRCoS, as well as compatibility with clinical environments. The GUI is based on an uncomplicated set of panels and a renewed Application Program Interface (API). Compared to the previous versions, the MaRGA package ("MaRCoS Graphical Application") includes new functionalities such as the possibility to export images to standard DICOM formats, create and manage clinical protocols, or display and process image reconstructions, among other features conceived to simplify the operation of MRI scanners. All prototypes in our facilities are commanded by MaRCoS and operated with the new GUI. Here we report on its performance on an experimental 0.2 T scanner designed for hard-tissue imaging, as well as a 72~mT portable scanner presently installed in the radiology department of a large hospital. The possibility to customize, adapt and streamline processes has substantially improved our workflows and overall experience.
△ Less
Submitted 14 December, 2023;
originally announced December 2023.
-
Portable MRI for major sporting events -- a case study on the MotoGP World Championship
Authors:
J. M. Algarín,
T. Guallart-Naval,
E. Gastaldi-Orquín,
R. Bosch,
F. J. Lloris,
E. Pallás,
J. P. Rigla,
P. Martínez,
J. Borreguero,
R. Alamar,
L. Martí-Bonmatí,
J. M. Benlloch,
F. Galve,
J. Alonso
Abstract:
The goal of this work is to showcase the clinical value that portable MRI can provide in crowded events and major sports competitions. We temporarily installed a low-field and low-cost portable MRI system for extremity imaging in the medical facilities of the Ricardo Tormo Motor Racing Circuit during the four days of the Motorcycle Grand Prix held in Valencia (Spain), which closed the 2022 season…
▽ More
The goal of this work is to showcase the clinical value that portable MRI can provide in crowded events and major sports competitions. We temporarily installed a low-field and low-cost portable MRI system for extremity imaging in the medical facilities of the Ricardo Tormo Motor Racing Circuit during the four days of the Motorcycle Grand Prix held in Valencia (Spain), which closed the 2022 season of the MotoGP. During this time, we scanned 14 subjects, running a total of 21 protocols for wrist, knee and ankle imaging. Each protocol included a minimum of one T1-weighted 3D-RARE sequence for general anatomical information, and one 3D-STIR sequence to highlight fluid accumulation and inflammation. The circuit medical staff were able to visualize a number of lesions and conditions in the low-field reconstructions, including gonarthrosis, effusion, or Haglund's syndrome, as well as metallic implants and tissue changes due to surgical interventions. Out of eight low-field acquisitions on previously diagnosed lesions, only two (a meniscus tear and a Baker cyst) were not detected by the experts that evaluated our images. The main highlight was that a low-field MRI scan on a subject reporting pain in a wrist revealed a traumatic arthritis which an X-ray radiograph and visual inspection had missed. We have operated in a scenario where high-field MRI is unlikely to play a role but where a low-field system can lead to improved medical attention. In the case reported here, system transport, installation in the circuit facilities and calibration were all uncomplicated. The images presented to the medical staff were mostly unprocessed and there is thus room for improvement. In conclusion, this work supports the claim that low-field MRI can likely provide added value whenever concepts such as accessibility, portability and low-cost outweigh exquisite detail in images.
△ Less
Submitted 17 March, 2023; v1 submitted 16 March, 2023;
originally announced March 2023.
-
MaRCoS, an open-source electronic control system for low-field MRI
Authors:
Vlad Negnevitsky,
Yolanda Vives-Gilabert,
José M. Algarín,
Lincoln Craven-Brightman,
Rubén Pellicer-Guridi,
Thomas O'Reilly,
Jason P. Stockmann,
Andrew Webb,
Joseba Alonso,
Benjamin Menküc
Abstract:
Every magnetic resonance imaging (MRI) device requires an electronic control system that handles pulse sequences and signal detection and processing. Here we provide details on the architecture and performance of MaRCoS, a MAgnetic Resonance COntrol System developed by an open international community of low-field MRI researchers. MaRCoS is inexpensive and can handle cycle-accurate sequences withou…
▽ More
Every magnetic resonance imaging (MRI) device requires an electronic control system that handles pulse sequences and signal detection and processing. Here we provide details on the architecture and performance of MaRCoS, a MAgnetic Resonance COntrol System developed by an open international community of low-field MRI researchers. MaRCoS is inexpensive and can handle cycle-accurate sequences without hard length limitations, rapid bursts of events, and arbitrary waveforms. It can also be easily adapted to meet further specifications required by the various academic and private institutions participating in its development. We describe the MaRCoS hardware, firmware and software that enable all of the above, including a Python-based graphical user interface for pulse sequence implementation, data processing and image reconstruction.
△ Less
Submitted 2 August, 2022;
originally announced August 2022.
-
Benchmarking the performance of a low-cost Magnetic Resonance Control System at multiple sites in the open MaRCoS community
Authors:
T. Guallart-Naval,
T. O'Reilly,
J. M. Algarín,
R. Pellicer-Guridi,
Y. Vives-Gilabert,
L. Craven-Brightman,
V. Negnevitsky,
B. Menküc,
F. Galve,
J. P. Stockmann,
A. Webb,
J. Alonso
Abstract:
Purpose: To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. Methods: This paper describes three different setups from 50 to 360 mT in different settings, all of which used the MaRCoS console for acquiring data, and d…
▽ More
Purpose: To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. Methods: This paper describes three different setups from 50 to 360 mT in different settings, all of which used the MaRCoS console for acquiring data, and different types of software interfaces (custom-built GUI or PulSeq overlay) to acquire the data. Results: Images are presented from both phantoms and in vivo from healthy volunteers to demonstrate the image quality that can be obtained from the MaRCoS hardware/software interfaced to different low-field magnets. Conclusions: The results presented here show that a number of different sequences commonly used in the clinic can be programmed into an open-source system relatively quickly and easily, and can produce good quality images even at this early stage of development. Both the hardware and software will continue to develop, and it is an aim of this paper to encourage other groups to join this international consortium.
△ Less
Submitted 15 February, 2023; v1 submitted 21 March, 2022;
originally announced March 2022.
-
Portable magnetic resonance imaging of patients indoors, outdoors and at home
Authors:
T. Guallart-Naval,
J. M. Algarín,
R. Pellicer-Guridi,
F. Galve,
Y. Vives-Gilabert,
R. Bosch,
E. Pallás,
J. M. González,
J. P. Rigla,
P. Martínez,
F. J. Lloris,
J. Borreguero,
A. Marcos-Perucho,
V. Negnevitsky,
L. Martí-Bonmatí,
A. Ríos,
J. M. Benlloch,
J. Alonso
Abstract:
Mobile medical imaging devices are invaluable for clinical diagnostic purposes both in and outside healthcare institutions. Among the various imaging modalities, only a few are readily portable. Magnetic resonance imaging (MRI), the gold standard for numerous healthcare conditions, does not traditionally belong to this group. Recently, low-field MRI start-up companies have demonstrated the first d…
▽ More
Mobile medical imaging devices are invaluable for clinical diagnostic purposes both in and outside healthcare institutions. Among the various imaging modalities, only a few are readily portable. Magnetic resonance imaging (MRI), the gold standard for numerous healthcare conditions, does not traditionally belong to this group. Recently, low-field MRI start-up companies have demonstrated the first decisive steps towards portability within medical facilities, but these are so far incompatible with more demanding use cases such as in remote and develo** regions, sports facilities and events, medical and military camps, or home healthcare. Here we present in vivo images taken with a light, home-made, low-field extremity MRI scanner outside the controlled environment provided by medical facilities. To demonstrate the true portability of the system and benchmark its performance in various relevant scenarios, we have acquired images of a volunteer's knee in: i) an MRI physics laboratory; ii) an office room; iii) outside a campus building, connected to a nearby power outlet; iv) in open air, powered from a small fuel-based generator; and v) at the volunteer's home. All images have been acquired within clinically viable times, and signal-to-noise ratios (SNR) and tissue contrast suffice for 2D and 3D reconstructions with diagnostic value, with comparable overall image quality across all five situations. Furthermore, the volunteer carries a fixation metallic implant screwed to the femur, which leads to strong artifacts in standard clinical systems but appears sharp in our low-field acquisitions. Altogether, this work opens a path towards highly accessible MRI under circumstances previously unrealistic.
△ Less
Submitted 15 February, 2023; v1 submitted 7 March, 2022;
originally announced March 2022.
-
Slice-selective Zero Echo Time imaging of ultra-short T2 tissues based on spin-locking
Authors:
J. Borreguero,
F. Galve,
J. M. Algarín,
J. M. Benlloch,
J. Alonso
Abstract:
Purpose: To expand the capabilities of Zero Echo Time (ZTE) pulse sequences with a slice selection method suitable for the shortest-lived tissues in the body.
Methods: We introduce two new sequences that integrate spin-locking pulses into standard ZTE imaging to achieve slice selection: one for moderately short $T_2$ (DiSLoP), the other for ultra-short $T_2$ samples (PreSLoP). These methods expl…
▽ More
Purpose: To expand the capabilities of Zero Echo Time (ZTE) pulse sequences with a slice selection method suitable for the shortest-lived tissues in the body.
Methods: We introduce two new sequences that integrate spin-locking pulses into standard ZTE imaging to achieve slice selection: one for moderately short $T_2$ (DiSLoP), the other for ultra-short $T_2$ samples (PreSLoP). These methods exploit the slower signal decay (at $T_{1ρ}\gg T_2$) to retain the magnetization in the slices during the selection process, which is otherwise comparable to or even much longer than $T_2$.
Results: We demonstrate control over the slice profiles and positions for 2D imaging. We measure magnetization decay times during spin-locking ($T_{1ρ}$) as a function of pulse amplitude, showing significant lifetime enhancement for amplitudes as low as 10 uT. We show imaging of slice-selected samples with $T_2$ characteristic times in the range of single milliseconds with DiSLoP and PreSLoP, and with the latter for sub-millisecond $T_2$ tissues. As compared to standard 3D ZTE sequences, PreSLoP achieves the same signal-to-noise ratio (SNR) in 2-5 times shorter scan times, and we argue that this is due to the filling scheme of the finite gap at the center of $k$-space unavoidable with ZTE sequences. Finally, we discuss a combination of DiSLoP with a dynamical decoupling sequence to avoid this central gap, leading to further scan time accelerations.
Conclusions: The proposed sequences are capable of slice-selected 2D imaging of tissues with $T_2$ as low as 275 us with good SNR within clinically acceptable scan times.
△ Less
Submitted 17 January, 2022;
originally announced January 2022.
-
Prepolarized MRI of Hard Tissues and Solid-State Matter
Authors:
J. M. González,
J. Borreguero,
E. Pallás,
J. P. Rigla,
J. M. Algarín,
R. Bosch,
F. Galve,
D. Grau-Ruiz,
R. Pellicer,
A. Ríos,
J. M. Benlloch,
J. Alonso
Abstract:
Prepolarized Magnetic Resonance Imaging (PMRI) is a long-established technique conceived to counteract the loss in signal-to-noise ratio (SNR) inherent to low-field MRI systems. When it comes to hard biological tissues and solid-state matter, PMRI is severely restricted by their ultra-short characteristic relaxation times. Here we demonstrate that efficient hard tissue prepolarization is within re…
▽ More
Prepolarized Magnetic Resonance Imaging (PMRI) is a long-established technique conceived to counteract the loss in signal-to-noise ratio (SNR) inherent to low-field MRI systems. When it comes to hard biological tissues and solid-state matter, PMRI is severely restricted by their ultra-short characteristic relaxation times. Here we demonstrate that efficient hard tissue prepolarization is within reach with a special-purpose 0.26 T scanner designed for dental MRI and equipped with suitable high-power electronics. We have characterized the performance of a 0.5 T prepolarizer module which can be switched on and off in just 200 us. To that end, we have used resin, dental and bone samples, all with T1 times in the order of 20 ms at our field strength. The measured SNR enhancement is in good agreement with a simple theoretical model, and small deviations in extreme regimes can be attributed to mechanical vibrations due to the magnetic interaction between the prepolarization and main magnets. Finally, we argue that these results can be applied to clinical dental imaging, opening the door to replacing hazardous X-ray systems with low-field PMRI scanners.
△ Less
Submitted 8 October, 2021; v1 submitted 7 October, 2021;
originally announced October 2021.
-
A Fast 0.5T Prepolarizer Module for Preclinical Magnetic Resonance Imaging
Authors:
J. P. Rigla,
J. Borreguero,
C. Gramage,
E. Pallás,
J. M. González,
R. Bosch,
J. M. Algarín,
J. V. Sanchez-Andres,
F. Galve,
D. Grau-Ruiz,
R. Pellicer,
A. Ríos,
J. M. Benlloch,
J. Alonso
Abstract:
We present a magnet and high power electronics for Prepolarized Magnetic Resonance Imaging (PMRI) in a home-made, special-purpose preclinical system designed for simultaneous visualization of hard and soft biological tissues. PMRI boosts the signal-to-noise ratio (SNR) by means of a long and strong magnetic pulse which must be rapidly switched off prior to the imaging pulse sequence, in timescales…
▽ More
We present a magnet and high power electronics for Prepolarized Magnetic Resonance Imaging (PMRI) in a home-made, special-purpose preclinical system designed for simultaneous visualization of hard and soft biological tissues. PMRI boosts the signal-to-noise ratio (SNR) by means of a long and strong magnetic pulse which must be rapidly switched off prior to the imaging pulse sequence, in timescales shorter than the spin relaxation (or T1) time of the sample. We have operated the prepolarizer at up to 0.5 T and demonstrated enhanced magnetization, image SNR and tissue contrast with PMRI of tap water, an ex vivo mouse brain and food samples. These have T1 times ranging from hundreds of milli-seconds to single seconds, while the preliminary high-power electronics setup employed in this work can switch off the prepolarization field in tens of milli-seconds. In order to make this system suitable for solid-state matter and hard tissues, which feature T1 times as short as 10 ms, we are develo** new electronics which can cut switching times to ~300 us. This does not require changes in the prepolarizer module, opening the door to the first experimental demonstration of PMRI on hard biological tissues.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
Peripheral Nerve Stimulation limits with fast narrow and broad-band pulses
Authors:
D. Grau-Ruiz,
J. P. Rigla,
E. Pallás,
J. M. Algarín,
J. Borreguero,
R. Bosch,
G. Comazzi,
E. Díaz-Caballero,
F. Galve,
C. Gramage,
J. M. González,
R. Pellicer,
A. Ríos,
J. M. Benlloch,
J. Alonso
Abstract:
Peripheral Nerve Stimulation (PNS) constrains the clinical performance of Magnetic Resonance and Particle Imaging (MRI and MPI) systems. Extensive magneto-stimulation studies have been carried out recently in the field of MPI, where typical operation frequencies range from single to tens of kilo-hertz. PNS literature is scarce for MRI in this regime, where the resonant character of MPI coils preve…
▽ More
Peripheral Nerve Stimulation (PNS) constrains the clinical performance of Magnetic Resonance and Particle Imaging (MRI and MPI) systems. Extensive magneto-stimulation studies have been carried out recently in the field of MPI, where typical operation frequencies range from single to tens of kilo-hertz. PNS literature is scarce for MRI in this regime, where the resonant character of MPI coils prevents studies of broad-band excitation pulses. We have constructed an apparatus for PNS threshold determination on a subject's limb, capable of narrow and broad-band magnetic excitation with pulse characteristic times down to 40 us. From a first set of measurements on 51 volunteers, we observe that PNS limits coincide for sinusoidal (biphasic narrow-band) and triangular (biphasic broad-band) excitations, and are slightly lower for trapezoidal (monophasic broad-band) pulses. We have also measured statistically significant correlations of PNS sensitivity with arm size and body weight, and no correlation with height or gender. As opposed to resonant systems, our setup allows the execution of arbitrarily short pulse trains. We have confirmed thresholds increase significantly as trains transition from tens to a few pulses also in these fast timescales. By changing the polarity of the coils in our setup, we also looked at the influence of the spatial distribution of magnetic field strength on PNS effects. We find that thresholds are higher in an approximately linearly inhomogeneous field (relevant to MRI) than in a rather homogeneous distribution (as in MPI). Finally, given the large intersubject variability of PNS sensitivity, we propose employing a versatile low-cost system (such as presented here) for fast offline determination of a subject's limits prior to medical scanning, and then using this information to boost clinical imaging while preserving the patient's safety.
△ Less
Submitted 11 December, 2020;
originally announced December 2020.
-
Model-driven reconstruction with phase-constrained highly-oversampled MRI
Authors:
F. Galve,
J. Alonso,
J. M. Algarín,
J. M. Benlloch
Abstract:
The Nyquist-Shannon theorem states that the information accessible by discrete Fourier protocols saturates when the sampling rate reaches twice the bandwidth of the detected continuous time signal. This maximum rate (the NS-limit) plays a prominent role in Magnetic Resonance Imaging (MRI). Nevertheless, reconstruction methods other than Fourier analysis can extract useful information from data ove…
▽ More
The Nyquist-Shannon theorem states that the information accessible by discrete Fourier protocols saturates when the sampling rate reaches twice the bandwidth of the detected continuous time signal. This maximum rate (the NS-limit) plays a prominent role in Magnetic Resonance Imaging (MRI). Nevertheless, reconstruction methods other than Fourier analysis can extract useful information from data oversampled with respect to the NS-limit, given that relevant prior knowledge is available. Here we present PhasE-Constrained OverSampled MRI (PECOS), a method that exploits data oversampling in combination with prior knowledge of the physical interactions between electromagnetic fields and spins in MRI systems. In PECOS, highly oversampled-in-time k-space data are fed into a phase-constrained variant of Kaczmarz's algebraic reconstruction algorithm, where prior knowledge of the expected spin contributions to the signal is codified into an encoding matrix. PECOS can be used for scan acceleration in relevant scenarios by oversampling along frequency-encoded directions, which is innocuous in MRI systems under reasonable conditions. We find situations in which the reconstruction quality can be higher than with NS-limited acquisitions and traditional Fourier reconstruction. Besides, we compare the performance of a variety of encoding pulse sequences as well as image reconstruction protocols, and find that accelerated spiral trajectories in k-space combined with algebraic reconstruction techniques are particularly advantageous. The proposed sampling and reconstruction method is able to improve image quality for fully-sampled k-space trajectories, while allowing accelerated or undersampled acquisitions without regularization or signal extrapolation to unmeasured regions.
△ Less
Submitted 11 December, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Simultaneous imaging of hard and soft biological tissues in a low-field dental MRI scanner
Authors:
J. M. Algarín,
E. Díaz-Caballero,
J. Borreguero,
F. Galve,
D. Grau-Ruiz,
J. P. Rigla,
R. Bosch,
J. M. González,
E. Pallás,
M. Corberán,
C. Gramage,
S. Aja-Fernández,
A. Ríos,
J. M. Benlloch,
J. Alonso
Abstract:
Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some medical applications, such as dentistry, continues to be limited. Here, we present three-dimensional reconstructions of ex-vivo human teeth, as well as a rabbit head…
▽ More
Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some medical applications, such as dentistry, continues to be limited. Here, we present three-dimensional reconstructions of ex-vivo human teeth, as well as a rabbit head and part of a cow femur, all obtained at a field strength of only 260 mT. These images are the first featuring soft and hard tissues simultaneously at sub-Tesla fields, and they have been acquired in a home-made, special-purpose, pre-medical MRI scanner designed with the goal of demonstrating dental imaging at low field settings. We encode spatial information with two variations of zero-echo time (ZTE) pulse sequences: Pointwise-Encoding Time reduction with Radial Acquisition (PETRA) and a new sequence we have called Double Radial Non-Stop Spin Echo (DRaNSSE), which we find to perform better than the former. For image reconstruction we employ Algebraic Reconstruction Techniques (ART) as well as standard Fourier methods. A noise analysis of the resulting images shows that ART reconstructions exhibit a higher signal to noise ratio with a more homogeneous noise distribution.
△ Less
Submitted 4 May, 2020;
originally announced May 2020.
-
Low-field electromagnet for a high-resolution MRI system
Authors:
Juan P. Rigla,
Franz Bodker,
Amir Anari,
Eduardo Pallás,
Daniel Grau,
Guillermo Puchalt,
José M. González,
Miguel Corberán,
Elena Díaz,
José M. Algarín,
Alfonso Ríos,
José M. Benlloch,
Joseba Alonso
Abstract:
This paper presents the design and experimental characterization of a 1 T electromagnet tailored to meet the demands of a Magnetic Resonance Imaging (MRI) system conceived for spatial resolutions at the level of tens of microns. For high image quality, MRI requires an homogeneous magnetic field over the Field of View (FoV) where the sample is imaged. We measure the relative inhomogeneity of the fi…
▽ More
This paper presents the design and experimental characterization of a 1 T electromagnet tailored to meet the demands of a Magnetic Resonance Imaging (MRI) system conceived for spatial resolutions at the level of tens of microns. For high image quality, MRI requires an homogeneous magnetic field over the Field of View (FoV) where the sample is imaged. We measure the relative inhomogeneity of the field generated by our magnet to be well below 100 parts per million over a spherical FoV of 20 mm diameter, while strongly constraining fringe field lines to avoid interference with other devices. The magnet performance closely follows our expectations from numerical simulations in all the experimental tests carried out. Additionally, we present the solutions adopted for thermal management and the design of a mechanical structure to distribute the weight and integrate the platform to move the sample in and out of the magnet.
△ Less
Submitted 17 August, 2018;
originally announced August 2018.
-
Activation of Microwave Fields in a Spin-Torque Nano-Oscillator by Neuronal Action Potentials
Authors:
J. M. Algarin,
B. Ramaswamy,
L. Venuti,
M. E. Swierzbinski,
J. Baker-McKee,
I. N. Weinberg,
Y. J. Chen,
I. N. Krivorotov,
J. A. Katine,
J. Herberholz,
R. C. Araneda,
B. Shapiro,
E. Waks
Abstract:
Action potentials are the basic unit of information in the nervous system and their reliable detection and decoding holds the key to understanding how the brain generates complex thought and behavior. Transducing these signals into microwave field oscillations can enable wireless sensors that report on brain activity through magnetic induction. In the present work we demonstrate that action potent…
▽ More
Action potentials are the basic unit of information in the nervous system and their reliable detection and decoding holds the key to understanding how the brain generates complex thought and behavior. Transducing these signals into microwave field oscillations can enable wireless sensors that report on brain activity through magnetic induction. In the present work we demonstrate that action potentials from crayfish lateral giant neuron can trigger microwave oscillations in spin-torque nano-oscillators. These nanoscale devices take as input small currents and convert them to microwave current oscillations that can wirelessly broadcast neuronal activity, opening up the possibility for compact neuro-sensors. We show that action potentials activate microwave oscillations in spin-torque nano-oscillators with an amplitude that follows the action potential signal, demonstrating that the device has both the sensitivity and temporal resolution to respond to action potentials from a single neuron. The activation of magnetic oscillations by action potentials, together with the small footprint and the high frequency tunability, makes these devices promising candidates for high resolution sensing of bioelectric signals from neural tissues. These device attributes may be useful for design of high-throughput bi-directional brain-machine interfaces.
△ Less
Submitted 16 October, 2017;
originally announced October 2017.
-
Image acceleration in parallel magnetic resonance imaging by means of metamaterial magnetoinductive lenses
Authors:
Manuel J. Freire,
Marcos A. Lopez,
Jose M. Algarin,
Felix Breuer,
Ricardo Marqués
Abstract:
Parallel magnetic resonance imaging (MRI) is a technique of image acceleration which takes advantage of the localization of the field of view (FOV) of coils in an array. In this letter we show that metamaterial lenses based on capacitively-loaded rings can provide higher localization of the FOV. Several lens designs are systematically analyzed in order to find the structure providing higher signal…
▽ More
Parallel magnetic resonance imaging (MRI) is a technique of image acceleration which takes advantage of the localization of the field of view (FOV) of coils in an array. In this letter we show that metamaterial lenses based on capacitively-loaded rings can provide higher localization of the FOV. Several lens designs are systematically analyzed in order to find the structure providing higher signal-to-noise-ratio. The magnetoinductive (MI) lens is find to be the optimum structure and an experiment is developed to show it. The ability of the fabricated MI lenses to accelerate the image is quantified by means of the parameter known in the MRI community as g-factor.
△ Less
Submitted 10 December, 2011;
originally announced December 2011.
-
Active split-ring metamaterial slabs for magnetic resonance imaging
Authors:
Marcos A. Lopez,
Jose M. Algarin,
Manuel J. Freire,
Volker C. Behr,
Peter M. Jakob,
Ricardo Marques
Abstract:
In this work, it is analyzed the ability of split-ring metamaterial slabs with zero/high permeability to reject/confine the radiofrequency magnetic field in magnetic resonance imaging systems. Using an homogenization procedure, split-ring slabs have been designed and fabricated to work in a 1.5T system. Active elements consisting of pairs of crossed diodes are inserted in the split-rings. With the…
▽ More
In this work, it is analyzed the ability of split-ring metamaterial slabs with zero/high permeability to reject/confine the radiofrequency magnetic field in magnetic resonance imaging systems. Using an homogenization procedure, split-ring slabs have been designed and fabricated to work in a 1.5T system. Active elements consisting of pairs of crossed diodes are inserted in the split-rings. With these elements, the permeability of the slabs can be automatically switched between a unity value when interacting with the strong excitation field of the transmitting body coil, and zero or high values when interacting with the weak field produced by protons in tissue. Experiments are shown for different configurations where these slabs can help to locally increase the signal-to-noise-ratio.
△ Less
Submitted 13 February, 2011;
originally announced February 2011.