Skip to main content

Showing 1–3 of 3 results for author: Alessio, A

.
  1. arXiv:2402.09372  [pdf, other

    eess.IV cs.AI cs.CV

    Deep Rib Fracture Instance Segmentation and Classification from CT on the RibFrac Challenge

    Authors: Jiancheng Yang, Rui Shi, Liang **, Xiaoyang Huang, Kaiming Kuang, Donglai Wei, Shixuan Gu, Jianying Liu, Pengfei Liu, Zhizhong Chai, Yongjie Xiao, Hao Chen, Liming Xu, Bang Du, Xiangyi Yan, Hao Tang, Adam Alessio, Gregory Holste, Jiapeng Zhang, Xiaoming Wang, Jianye He, Lixuan Che, Hanspeter Pfister, Ming Li, Bingbing Ni

    Abstract: Rib fractures are a common and potentially severe injury that can be challenging and labor-intensive to detect in CT scans. While there have been efforts to address this field, the lack of large-scale annotated datasets and evaluation benchmarks has hindered the development and validation of deep learning algorithms. To address this issue, the RibFrac Challenge was introduced, providing a benchmar… ▽ More

    Submitted 14 February, 2024; originally announced February 2024.

    Comments: Challenge paper for MICCAI RibFrac Challenge (https://ribfrac.grand-challenge.org/)

  2. arXiv:1608.04381  [pdf, other

    physics.med-ph cs.CV

    Automated Selection of Uniform Regions for CT Image Quality Detection

    Authors: Maitham D Naeemi, Adam M Alessio, Sohini Roychowdhury

    Abstract: CT images are widely used in pathology detection and follow-up treatment procedures. Accurate identification of pathological features requires diagnostic quality CT images with minimal noise and artifact variation. In this work, a novel Fourier-transform based metric for image quality (IQ) estimation is presented that correlates to additive CT image noise. In the proposed method, two windowed CT i… ▽ More

    Submitted 19 August, 2016; v1 submitted 13 August, 2016; originally announced August 2016.

    Comments: 5 pages, 8 figures, Asilomar Conference on Signals, Systems, and Computers

  3. arXiv:1605.07650  [pdf

    cs.CV physics.med-ph

    Blind Analysis of CT Image Noise Using Residual Denoised Images

    Authors: Sohini Roychowdhury, Nathan Hollraft, Adam Alessio

    Abstract: CT protocol design and quality control would benefit from automated tools to estimate the quality of generated CT images. These tools could be used to identify erroneous CT acquisitions or refine protocols to achieve certain signal to noise characteristics. This paper investigates blind estimation methods to determine global signal strength and noise levels in chest CT images. Methods: We propose… ▽ More

    Submitted 24 May, 2016; originally announced May 2016.

    Comments: 4 pages, 6 figures, IEEE NSS/MIC 2015