-
FIREBall-2: flight preparation of a proven balloon payload to image the intermediate redshift circumgalactic medium
Authors:
Vincent Picouet,
David Valls-Gabaud,
Bruno Milliard,
David Schiminovich,
Drew M. Miles,
Keri Hoadley,
Erika Hamden,
D. Christopher Martin,
Gillian Kyne,
Trent Brendel,
Aafaque Raza Khan,
Jean Evrard,
Zeren Lin,
Haeun Chung,
Simran Agarwal,
Ignacio Cevallos Aleman,
Charles-Antoine Chevrier,
Jess Li,
Nicole Melso,
Shouleh Nikzad,
Didier Vibert,
Nicolas Bray
Abstract:
FIREBall-2 is a stratospheric balloon-borne 1-m telescope coupled to a UV multi-object slit spectrograph designed to map the faint UV emission surrounding z~0.7 galaxies and quasars through their Lyman-alpha line emission. This spectro-imager had its first launch on September 22nd 2018 out of Ft. Sumner, NM, USA. Because the balloon was punctured, the flight was abruptly interrupted. Instead of th…
▽ More
FIREBall-2 is a stratospheric balloon-borne 1-m telescope coupled to a UV multi-object slit spectrograph designed to map the faint UV emission surrounding z~0.7 galaxies and quasars through their Lyman-alpha line emission. This spectro-imager had its first launch on September 22nd 2018 out of Ft. Sumner, NM, USA. Because the balloon was punctured, the flight was abruptly interrupted. Instead of the nominal 8 hours above 32 km altitude, the instrument could only perform science acquisition for 45 minutes at this altitude. In addition, the shape of the deflated balloon, combined with a full Moon, revealed a severe off-axis scattered light path, directly into the UV science detector and about 100 times larger than expected. In preparation for the next flight, and in addition to describing FIREBall-2's upgrade, this paper discusses the exposure time calculator (ETC) that has been designed to analyze the instrument's optimal performance (explore the instrument's limitations and subtle trade-offs).
△ Less
Submitted 28 November, 2022;
originally announced November 2022.
-
The Circumgalactic H$α$ Spectrograph (CH$α$S) I. Design, Engineering, and Early Commissioning
Authors:
Nicole Melso,
David Schiminovich,
Brian Smiley,
Hwei Ru Ong,
Bárbara Cruvinel Santiago,
Meghna Sitaram,
Ignacio Cevallos Aleman,
Sarah Graber,
Marisa Murillo,
Marni Rosenthal,
Ioana Stelea
Abstract:
The Circumgalactic H$α$ Spectrograph (CH$α$S) is a ground-based optical integral field spectrograph designed to detect ultra-faint extended emission from diffuse ionized gas in the nearby universe. CH$α$S is particularly well suited for making a direct detection of tenuous H$α$ emission from the circumgalactic medium (CGM) surrounding low-redshift galaxies. It efficiently maps large regions of the…
▽ More
The Circumgalactic H$α$ Spectrograph (CH$α$S) is a ground-based optical integral field spectrograph designed to detect ultra-faint extended emission from diffuse ionized gas in the nearby universe. CH$α$S is particularly well suited for making a direct detection of tenuous H$α$ emission from the circumgalactic medium (CGM) surrounding low-redshift galaxies. It efficiently maps large regions of the CGM in a single exposure, targeting nearby galaxies (d $< 35 $ Mpc) where the CGM is expected to fill the field of view. We are commissioning CH$α$S as a facility instrument at MDM Observatory. CH$α$S is deployed in the focal plane of the Hiltner 2.4-meter telescope, utilizing nearly all of the telescope's unvignetted focal plane (10 arcmin) to conduct wide-field spectroscopic imaging. The catadioptric design provides excellent wide-field imaging performance. CH$α$S is a pupil-imaging spectrograph employing a microlens array to divide the field of view into $> 60,000$ spectra. CH$α$S achieves an angular resolution of $[1.3 - 2.8]$ arcseconds and a resolving power of R$ = [10,000 - 20,000]$. Accordingly, the spectrograph can resolve structure on the scale of $1-5$ kpc (at 10 Mpc) and measure velocities down to 15-30 km/s. CH$α$S intentionally operates over a narrow (30 Angstrom) bandpass; however, it is configured to adjust the central wavelength and target a broad range of optical emission lines individually. A high diffraction efficiency VPH grating ensures high throughput across configurations. CH$α$S maintains a high grasp and moderate spectral resolution, providing an ideal combination for map** discrete, ultra-low surface brightness emission on the order of a few milli-Raleigh.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.
-
Structural Origin of Boson Peak in Glasses
Authors:
Yuan Tian,
Xiaozhe Shen,
Qingyang Gao,
Zhen Lu,
Jie Yang,
Qiang Zheng,
Christopher Florencio Aleman,
Duan Luo,
Alexander Hume Reid,
Bin Xu,
Michael Falk,
Howard Sheng,
Jianming Cao,
Xijie Wang,
Mingwei Chen
Abstract:
Boson peak, the excess low energy excitations in the terahertz regime, is one of the most unique features of disordered systems and has been linked to many anomalous properties of glass materials. The nature and structural origin of the boson peak remain elusive and have been debated for more than a half century mainly due to the lack of real-time and real-space experimental insights of the dynami…
▽ More
Boson peak, the excess low energy excitations in the terahertz regime, is one of the most unique features of disordered systems and has been linked to many anomalous properties of glass materials. The nature and structural origin of the boson peak remain elusive and have been debated for more than a half century mainly due to the lack of real-time and real-space experimental insights of the dynamic phenomenon. In this work we employed femtosecond MeV ultrafast electron diffraction to characterize the atomic dynamics of metallic glasses in real time. The experiment reveals collective atomic oscillations, presented in elastic electron scattering and atomic pair distribution functions, within the boson peak frequency range of 1.0-1.8 THz in both reciprocal and real space. It was found that the oscillation frequency has reciprocal dependence on interatomic pair distances and the corresponding wave velocity experimentally affirms the transverse acoustic wave nature of the boson peak. The observed strong correlation between THz acoustic vibrations and coherent electron scattering provides compelling evidence that the boson peak originates from the collective transverse vibrational modes of structurally ordered atoms in the disordered system.
△ Less
Submitted 19 November, 2021;
originally announced November 2021.
-
Measurement of the ($π^-$, Ar) total hadronic cross section at the LArIAT experiment
Authors:
E. Gramellini,
J. Ho,
R. Acciarri,
C. Adams,
J. Asaadi,
M. Backfish,
W. Badgett,
B. Baller,
V. Basque,
O. Benevides Rodrigues,
F. d. M. Blaszczyk,
R. Bouabid,
C. Bromberg,
R. Carey,
R. Castillo Fernandez,
F. Cavanna,
J. I. Cevallos Aleman,
A. Chatterjee,
P. Dedin,
M. V. dos Santos,
D. Edmunds,
C. Escobar,
J. Esquivel,
J. J. Evans,
A. Falcone
, et al. (73 additional authors not shown)
Abstract:
We present the first measurement of the negative pion total hadronic cross section on argon, which we performed at the Liquid Argon In A Testbeam (LArIAT) experiment. All hadronic reaction channels, as well as hadronic elastic interactions with scattering angle greater than 5~degrees are included. The pions have a kinetic energies in the range 100-700~MeV and are produced by a beam of charged part…
▽ More
We present the first measurement of the negative pion total hadronic cross section on argon, which we performed at the Liquid Argon In A Testbeam (LArIAT) experiment. All hadronic reaction channels, as well as hadronic elastic interactions with scattering angle greater than 5~degrees are included. The pions have a kinetic energies in the range 100-700~MeV and are produced by a beam of charged particles im**ing on a solid target at the Fermilab Test Beam Facility. LArIAT employs a 0.24~ton active mass Liquid Argon Time Projection Chamber (LArTPC) to measure the pion hadronic interactions. For this measurement, LArIAT has developed the ``thin slice method", a new technique to measure cross sections with LArTPCs. While generally higher than the prediction, our measurement of the ($π^-$,Ar) total hadronic cross section is in agreement with the prediction of the Geant4 model when considering a model uncertainty of $\sim$5.1\%.
△ Less
Submitted 7 July, 2022; v1 submitted 30 July, 2021;
originally announced August 2021.
-
The Liquid Argon In A Testbeam (LArIAT) Experiment
Authors:
LArIAT Collaboration,
R. Acciarri,
C. J. Adams,
J. Asaadi,
M. Backfish,
W. Badgett,
B. Baller,
O. Benevides Rodrigues,
F. d. M. Blaszczyk,
R. Bouabid,
C. Bromberg,
R. Carey,
R. Castillo Fernandez,
F. Cavanna,
J. I. Cevallos Aleman,
A. Chatterjee,
P. Dedin Neto,
M. V. Dos Santos,
S. Dytman,
D. Edmunds,
M. Elkins,
C. O. Escobar,
J. Esquivel,
J. Evans,
A. Falcone
, et al. (81 additional authors not shown)
Abstract:
The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.
The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 300-1400 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.
△ Less
Submitted 6 February, 2020; v1 submitted 23 November, 2019;
originally announced November 2019.
-
Calorimetry for low-energy electrons using charge and light in liquid argon
Authors:
W. Foreman,
R. Acciarri,
J. A. Asaadi,
W. Badgett,
F. d. M. Blaszczyk,
R. Bouabid,
C. Bromberg,
R. Carey,
F. Cavanna,
J. I. Cevallos Aleman,
A. Chatterjee,
J. Evans,
A. Falcone,
W. Flanagan,
B. T. Fleming,
D. Garcia-Gomez,
B. Gelli,
T. Ghosh,
R. A. Gomes,
E. Gramellini,
R. Gran,
P. Hamilton,
C. Hill,
J. Ho,
J. Hugon
, et al. (38 additional authors not shown)
Abstract:
Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-…
▽ More
Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enhance the physics reach of oscillation analyses. Liquid argon scintillation light has the potential to improve energy reconstruction for low-energy electrons over charge-based measurements alone. Here we demonstrate light-augmented calorimetry for low-energy electrons in a single-phase LArTPC using a sample of Michel electrons from decays of stop** cosmic muons in the LArIAT experiment at Fermilab. Michel electron energy spectra are reconstructed using both a traditional charge-based approach as well as a more holistic approach that incorporates both charge and light. A maximum-likelihood fitter, using LArIAT's well-tuned simulation, is developed for combining these quantities to achieve optimal energy resolution. A sample of isolated electrons is simulated to better determine the energy resolution expected for astrophysical electron-neutrino charged-current interaction final states. In LArIAT, which has very low wire noise and an average light yield of 18 pe/MeV, an energy resolution of $σ/E \simeq 9.3\%/\sqrt{E} \oplus 1.3\%$ is achieved. Samples are then generated with varying wire noise levels and light yields to gauge the impact of light-augmented calorimetry in larger LArTPCs. At a charge-readout signal-to-noise of S/N $\simeq$ 30, for example, the energy resolution for electrons below 40 MeV is improved by $\approx$ 10%, $\approx$ 20%, and $\approx$ 40% over charge-only calorimetry for average light yields of 10 pe/MeV, 20 pe/MeV, and 100 pe/MeV, respectively.
△ Less
Submitted 22 January, 2020; v1 submitted 17 September, 2019;
originally announced September 2019.
-
POLARBEAR-2: an instrument for CMB polarization measurements
Authors:
Y. Inoue,
P. Ade,
Y. Akiba,
C. Aleman,
K. Arnold,
C. Baccigalupi,
B. Barch,
D. Barron,
A. Bender,
D. Boettger,
J. Borrill,
S. Chapman,
Y. Chinone,
A. Cukierman,
T. de Haan,
M. A. Dobbs,
A. Ducout,
R. Dunner,
T. Elleflot,
J. Errard,
G. Fabbian,
S. Feeney,
C. Feng,
G. Fuller,
A. J. Gilbert
, et al. (61 additional authors not shown)
Abstract:
POLARBEAR-2 (PB-2) is a cosmic microwave background (CMB) polarization experiment that will be located in the Atacama highland in Chile at an altitude of 5200 m. Its science goals are to measure the CMB polarization signals originating from both primordial gravitational waves and weak lensing. PB-2 is designed to measure the tensor to scalar ratio, r, with precision σ(r) < 0.01, and the sum of neu…
▽ More
POLARBEAR-2 (PB-2) is a cosmic microwave background (CMB) polarization experiment that will be located in the Atacama highland in Chile at an altitude of 5200 m. Its science goals are to measure the CMB polarization signals originating from both primordial gravitational waves and weak lensing. PB-2 is designed to measure the tensor to scalar ratio, r, with precision σ(r) < 0.01, and the sum of neutrino masses, Σmν, with σ(Σmν) < 90 meV. To achieve these goals, PB-2 will employ 7588 transition-edge sensor bolometers at 95 GHz and 150 GHz, which will be operated at the base temperature of 250 mK. Science observations will begin in 2017.
△ Less
Submitted 9 August, 2016;
originally announced August 2016.
-
The POLARBEAR-2 and the Simons Array Experiment
Authors:
A. Suzuki,
P. Ade,
Y. Akiba,
C. Aleman,
K. Arnold,
C. Baccigalupi,
B. Barch,
D. Barron,
A. Bender,
D. Boettger,
J. Borrill,
S. Chapman,
Y. Chinone,
A. Cukierman,
M. Dobbs,
A. Ducout,
R. Dunner,
T. Elleflot,
J. Errard,
G. Fabbian,
S. Feeney,
C. Feng,
T. Fu**o,
G. Fuller,
A. Gilbert
, et al. (64 additional authors not shown)
Abstract:
We present an overview of the design and status of the \Pb-2 and the Simons Array experiments. \Pb-2 is a Cosmic Microwave Background polarimetry experiment which aims to characterize the arc-minute angular scale B-mode signal from weak gravitational lensing and search for the degree angular scale B-mode signal from inflationary gravitational waves. The receiver has a 365~mm diameter focal plane c…
▽ More
We present an overview of the design and status of the \Pb-2 and the Simons Array experiments. \Pb-2 is a Cosmic Microwave Background polarimetry experiment which aims to characterize the arc-minute angular scale B-mode signal from weak gravitational lensing and search for the degree angular scale B-mode signal from inflationary gravitational waves. The receiver has a 365~mm diameter focal plane cooled to 270~milli-Kelvin. The focal plane is filled with 7,588 dichroic lenslet-antenna coupled polarization sensitive Transition Edge Sensor (TES) bolometric pixels that are sensitive to 95~GHz and 150~GHz bands simultaneously. The TES bolometers are read-out by SQUIDs with 40 channel frequency domain multiplexing. Refractive optical elements are made with high purity alumina to achieve high optical throughput. The receiver is designed to achieve noise equivalent temperature of 5.8~$μ$K$_{CMB}\sqrt{s}$ in each frequency band. \Pb-2 will deploy in 2016 in the Atacama desert in Chile. The Simons Array is a project to further increase sensitivity by deploying three \Pb-2 type receivers. The Simons Array will cover 95~GHz, 150~GHz and 220~GHz frequency bands for foreground control. The Simons Array will be able to constrain tensor-to-scalar ratio and sum of neutrino masses to $σ(r) = 6\times 10^{-3}$ at $r = 0.1$ and $\sum m_ν(σ=1)$ to 40 meV.
△ Less
Submitted 22 December, 2015;
originally announced December 2015.
-
Development and characterization of the readout system for POLARBEAR-2
Authors:
D. Barron,
P. A. R. Ade,
Y. Akiba,
C. Aleman,
K. Arnold,
M. Atlas,
A. Bender,
D. Boettger,
J. Borrill,
S. Chapman,
Y. Chinone,
A. Cukierman,
M. Dobbs,
T. Elleflot,
J. Errard,
G. Fabbian,
C. Feng,
A. Gilbert,
N. Goeckner-Wald,
N. W. Halverson,
M. Hasegawa,
K. Hattori,
M. Hazumi,
W. L. Holzapfel,
Y. Hori
, et al. (47 additional authors not shown)
Abstract:
POLARBEAR-2 is a next-generation receiver for precision measurements of the polarization of the cosmic microwave background (Cosmic Microwave Background (CMB)). Scheduled to deploy in early 2015, it will observe alongside the existing POLARBEAR-1 receiver, on a new telescope in the Simons Array on Cerro Toco in the Atacama desert of Chile. For increased sensitivity, it will feature a larger area f…
▽ More
POLARBEAR-2 is a next-generation receiver for precision measurements of the polarization of the cosmic microwave background (Cosmic Microwave Background (CMB)). Scheduled to deploy in early 2015, it will observe alongside the existing POLARBEAR-1 receiver, on a new telescope in the Simons Array on Cerro Toco in the Atacama desert of Chile. For increased sensitivity, it will feature a larger area focal plane, with a total of 7,588 polarization sensitive antenna-coupled Transition Edge Sensor (TES) bolometers, with a design sensitivity of 4.1 uKrt(s). The focal plane will be cooled to 250 milliKelvin, and the bolometers will be read-out with 40x frequency domain multiplexing, with 36 optical bolometers on a single SQUID amplifier, along with 2 dark bolometers and 2 calibration resistors. To increase the multiplexing factor from 8x for POLARBEAR-1 to 40x for POLARBEAR-2 requires additional bandwidth for SQUID readout and well-defined frequency channel spacing. Extending to these higher frequencies requires new components and design for the LC filters which define channel spacing. The LC filters are cold resonant circuits with an inductor and capacitor in series with each bolometer, and stray inductance in the wiring and equivalent series resistance from the capacitors can affect bolometer operation. We present results from characterizing these new readout components. Integration of the readout system is being done first on a small scale, to ensure that the readout system does not affect bolometer sensitivity or stability, and to validate the overall system before expansion into the full receiver. We present the status of readout integration, and the initial results and status of components for the full array.
△ Less
Submitted 6 November, 2014; v1 submitted 27 October, 2014;
originally announced October 2014.