-
Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
Authors:
D. Yu. Akimov,
I. S. Aleksandrov,
F. B. Ata Kurbonova,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
Yu. I. Koskin,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy recons…
▽ More
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy reconstruction procedures, and evaluation of the efficiency of electron extraction from the liquid xenon to the gas phase.
△ Less
Submitted 15 May, 2024; v1 submitted 19 March, 2024;
originally announced March 2024.
-
Characterization of the ambient background in the RED-100 experiment location at Kalinin Nuclear Power Plant
Authors:
D. Y. Akimov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
B. O. Lavrov,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper descr…
▽ More
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper describes the external background conditions for the RED-100 experiment at Kalinin Nuclear Power Plant.
△ Less
Submitted 24 November, 2023; v1 submitted 1 November, 2023;
originally announced November 2023.
-
The RED-100 experiment
Authors:
D. Yu. Akimov,
I. S. Alexandrov,
R. R. Alyev,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
E. M. Glagovsky,
Y. V. Gusakov,
A. V. Khromov,
S. M. Kiselev,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is des…
▽ More
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is described. There is no correlation of the radioactive background at the experimental setup site with ON and OFF states of the reactor. The data taking run was carried out at the beginning of the year 2022 and covered both the reactor OFF and ON periods.
△ Less
Submitted 14 November, 2022; v1 submitted 30 September, 2022;
originally announced September 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
First ground-level laboratory test of the two-phase xenon emission detector RED-100
Authors:
D. Yu. Akimov,
V. A. Belov,
A. I. Bolozdynya,
Yu. V. Efremenko,
A. V. Etenko,
A. V. Galavanov,
D. V. Gouss,
Yu. V. Gusakov,
Dj. Ed. Kdib,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
Yu. A. Melikyan,
V. V. Moramzin,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
Yu. V. Stogov,
A. A. Vasin
Abstract:
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamats…
▽ More
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamatsu R11410-20 PMTs assembled in two planes on top and bottom. The electrode system is equipped with an electron shutter (a patented device) to reduce a "spontaneous" single-electron noise. The detector was tested in a ground-level laboratory. The obtained results demonstrate that detection of coherent elastic scattering of reactor antineutrinos off xenon nuclei at Kalinin nuclear power plant with the RED-100 detector is feasible with a threshold of 4 ionization electrons.
△ Less
Submitted 14 October, 2019;
originally announced October 2019.
-
Test of SensL SiPM coated with NOL-1 wavelength shifter in liquid xenon
Authors:
D. Yu. Akimov,
V. A. Belov,
O. V. Borshchev,
A. A. Burenkov,
Yu. L. Grishkin,
A. K. Karelin,
A. V. Kuchenkov,
A. N. Martemiyanov,
S. A. Ponomarenko,
G. E. Simakov,
V. N. Stekhanov,
N. M. Surin,
V. S. Timoshin,
O. Ya. Zeldovich
Abstract:
A SensL MicroFC-SMT-60035 6x6 mm$^2$ silicon photo-multiplier coated with a NOL-1 wavelength shifter have been tested in the liquid xenon to detect the 175-nm scintillation light. For comparison, a Hamamatsu vacuum ultraviolet sensitive MPPC VUV3 3x3 mm$^2$ was tested under the same conditions. The photodetection efficiency of $13.1 \pm 2.5$% and $6.0 \pm 1.0$%, correspondingly, is obtained.
A SensL MicroFC-SMT-60035 6x6 mm$^2$ silicon photo-multiplier coated with a NOL-1 wavelength shifter have been tested in the liquid xenon to detect the 175-nm scintillation light. For comparison, a Hamamatsu vacuum ultraviolet sensitive MPPC VUV3 3x3 mm$^2$ was tested under the same conditions. The photodetection efficiency of $13.1 \pm 2.5$% and $6.0 \pm 1.0$%, correspondingly, is obtained.
△ Less
Submitted 3 May, 2017; v1 submitted 5 April, 2017;
originally announced April 2017.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
New method of 85Kr reduction in a noble gas based low-background detector
Authors:
D. Yu. Akimov,
A. I. Bolozdynya,
A. A. Burenkov,
C. Hall,
A. G. Kovalenko,
V. V. Kuzminov,
G. E. Simakov
Abstract:
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much lar…
▽ More
Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much larger than the natural krypton that is already present. After the purification system reduces the total Kr concentration to the same level, the final 85Kr concentration will have been reduced even further by the dilution factor. A test cell for measurement of the activity of various Kr samples has been assembled, and the activity of 25-year-old Krypton has been measured. The measured activity agrees well with the expected activity accounting for the 85Kr abundance of the earth atmosphere in 1990 and the half-life of the isotope. Additional tests with a Kr sample produced in the year 1944 (before the atomic era) have been done in order to demonstrate the sensitivity of the test cell.
△ Less
Submitted 22 November, 2016;
originally announced November 2016.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Observation of light emission from Hamamatsu R11410-20 photomultiplier tubes
Authors:
D. Yu. Akimov,
A. I. Bolozdynya,
Yu. V. Efremenko,
V. A. Kaplin,
A. V. Khromov,
Yu. A. Melikyan,
V. V. Sosnovtsev
Abstract:
We have shown that high voltage biased Hamamatsu R11410-20 photomultipliers with a dark count rate above 10 kHz emit single photons. The effect has been observed in a few units at room temperature and temperatures reduced down to -60 degrees Celsius. The effect should be taken into account in experiments aimed on search for rare events with small energy depositions in massive liquid xenon detector…
▽ More
We have shown that high voltage biased Hamamatsu R11410-20 photomultipliers with a dark count rate above 10 kHz emit single photons. The effect has been observed in a few units at room temperature and temperatures reduced down to -60 degrees Celsius. The effect should be taken into account in experiments aimed on search for rare events with small energy depositions in massive liquid xenon detectors.
△ Less
Submitted 28 April, 2015;
originally announced April 2015.
-
Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV
Authors:
D. Yu. Akimov,
V. V. Afanasyev,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
Yu. V. Efremenko,
D. A. Egorov,
A. V. Etenko,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin,
A. M. Konovalov,
A. G. Kovalenko,
A. V. Kuchenkov,
A. V. Kumpan,
Yu. A. Melikyan,
R. I. Nikolaev,
D. G. Rudik,
V. V. Sosnovtsev
, et al. (1 additional authors not shown)
Abstract:
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predicti…
▽ More
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predictions. Decay time of scintillation at 2.82 keV is measured to be 25 +/- 3 ns at the electric field of 3.75 kV/cm.
△ Less
Submitted 8 August, 2014;
originally announced August 2014.
-
Two-phase xenon emission detector with electron multiplier and optical readout by multipixel avalanche Geiger photodiodes
Authors:
D. Yu. Akimov,
A. V. Akindinov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
A. F. Buzulutskov,
M. V. Danilov,
Yu. V. Efremenko,
M. A. Kirsanov,
A. G. Kovalenko,
V. N. Stekhanov
Abstract:
A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was demonstrated.
A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was demonstrated.
△ Less
Submitted 17 April, 2013; v1 submitted 29 March, 2013;
originally announced March 2013.
-
Measurement and simulation of the muon-induced neutron yield in lead
Authors:
L. Reichhart,
A. Lindote,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy
, et al. (14 additional authors not shown)
Abstract:
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well…
▽ More
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well the measured capture times and multiplicities and, within the dynamic range of the instrumentation, the spectrum of energy deposits. By comparing measurements with simulations of neutron capture rates a neutron yield in lead of (5.78^{+0.21}_{-0.28}) x 10^{-3} neutrons/muon/(g/cm^{2}) has been obtained. Absolute agreement between simulation and data is of order 25%. Consequences for deep underground rare event searches are discussed.
△ Less
Submitted 4 November, 2013; v1 submitted 18 February, 2013;
originally announced February 2013.
-
Perspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector
Authors:
RED Collaboration,
D. Yu. Akimov,
I. S. Alexandrov,
V. I. Aleshin,
V. A. Belov,
A. I. Bolozdynya,
A. A. Burenkov,
A. S. Chepurnov,
M. V. Danilov,
A. V. Derbin,
V. V. Dmitrenko,
A. G. Dolgolenko,
D. A. Egorov,
Yu. V. Efremenko,
A. V. Etenko,
M. B. Gromov,
M. A. Gulin,
S. V. Ivakhin,
V. A. Kantserov,
V. A. Kaplin,
A. K. Karelin,
A. V. Khromov,
M. A. Kirsanov,
S. G. Klimanov,
A. S. Kobyakin
, et al. (21 additional authors not shown)
Abstract:
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites…
▽ More
We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites have advantages as well as limitations. However the experiment looks feasible at either location. Preliminary design of the detector and supporting R&D program are discussed.
△ Less
Submitted 9 December, 2012;
originally announced December 2012.
-
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Authors:
V. N. Solovov,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (11 additional authors not shown)
Abstract:
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the…
▽ More
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
△ Less
Submitted 26 September, 2012; v1 submitted 7 December, 2011;
originally announced December 2011.
-
Performance data from the ZEPLIN-III second science run
Authors:
P. Majewski,
V. N. Solovov,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (10 additional authors not shown)
Abstract:
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the…
▽ More
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the instrument performance with emphasis on the position and energy reconstruction algorithm and summarise the final science results.
△ Less
Submitted 30 November, 2011;
originally announced December 2011.
-
Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator
Authors:
L. Reichhart,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling
, et al. (12 additional authors not shown)
Abstract:
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (…
▽ More
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (UPS-923A) is presented, exploring recoil energies between 125 keV and 850 keV. Monte Carlo simulations, incorporating light collection efficiency and energy resolution effects, are used to generate neutron scattering spectra which are matched to observed distributions of scintillation signals to parameterise the energy-dependent quenching factor. At energies above 300 keV the dependence is reasonably described using the semi-empirical formulation of Birks and a kB factor of (0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured quenching factor falls more steeply than predicted by the Birks formalism.
△ Less
Submitted 9 November, 2011;
originally announced November 2011.
-
WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling
, et al. (12 additional authors not shown)
Abstract:
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 ke…
▽ More
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 keV, which is compatible with background expectations. This allows the exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass with 90% confidence. Combined with data from the first run, this result improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its conclusion at Boulby, having deployed and exploited successfully three liquid xenon experiments of increasing reach.
△ Less
Submitted 16 December, 2011; v1 submitted 21 October, 2011;
originally announced October 2011.
-
Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
Authors:
E. Santos,
B. Edwards,
V. Chepel,
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
L. DeViveiros,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these…
▽ More
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of $\sim$3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Authors:
F. Neves,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. Preece
, et al. (12 additional authors not shown)
Abstract:
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d…
▽ More
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.
△ Less
Submitted 4 June, 2011;
originally announced June 2011.
-
Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
Authors:
M. Horn,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
C. Ghag,
A. Hollingsworth,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (11 additional authors not shown)
Abstract:
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r…
▽ More
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is found, together with a rising ionisation yield; both are in good agreement with the latest independent measurements. The analysis method is applied to both the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
△ Less
Submitted 17 October, 2011; v1 submitted 3 June, 2011;
originally announced June 2011.
-
Radioactivity Backgrounds in ZEPLIN-III
Authors:
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel. A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy. F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (10 additional authors not shown)
Abstract:
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level…
▽ More
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05$\pm$0.5 nuclear recoils with energy 5-50 keV per year, which translates to an expectation of 0.4 events in a 1-year dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from $β$ activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter $γ$-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of $\sim 1 \times 10^{-8}$ pb$\cdot$year to the scalar WIMP-nucleon elastic cross-section, as originally conceived.
△ Less
Submitted 12 August, 2011; v1 submitted 18 April, 2011;
originally announced April 2011.
-
Performance of the veto detector incorporated into the ZEPLIN-III experiment
Authors:
C. Ghag,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
K. Lyons,
P. Majewski,
A. St,
J. Murphy,
F. Neves
, et al. (14 additional authors not shown)
Abstract:
The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of…
▽ More
The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of operation in coincidence with ZEPLIN-III are presented. With fully automated operation and calibration, the veto system has maintained high stability and achieves near unity live time relative to ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60% of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be misidentified as WIMPs. This tagging efficiency reduces the expected untagged nuclear recoil background from neutrons during science data taking to a very low rate of ~0.2 events per year in the WIMP acceptance region. Additionally, the veto detector provides rejection of 28% of gamma-ray induced background events, allowing the sampling of the dominant source of background in ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will not be tagged by the veto detector, and tags due to gamma-rays and neutrons are separable, this population of multiple scatter events may be characterised without biasing the analysis of candidate WIMP signals in the data.
△ Less
Submitted 1 May, 2011; v1 submitted 2 March, 2011;
originally announced March 2011.
-
The ZEPLIN-III Anti-Coincidence Veto Detector
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim…
▽ More
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim has been to achieve a veto detector of low threshold and high efficiency without the creation of additional background in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of the components have been made, including radioactivity levels and performance characteristics. These have been used to inform a complete end-to-end Monte Carlo simulation that has then been used to calculate the expected performance of the new instrument, both operating alone and as an anti-coincidence detector for ZEPLIN-III. The veto device will be capable of rejecting over 65% of coincident nuclear recoil events from neutron background in the energy range of interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4 to ~0.14 events per year in the WIMP acceptance region, a significant factor in the event of a non-zero observation. Furthermore, in addition to providing valuable diagnostic capabilities, the veto is capable of tagging over 15% for gamma-ray rejection, all whilst contributing no significant additional background. In conjunction with the replacement of the internal ZEPLIN-III photomultiplier array, the new veto is expected to improve significantly the sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
△ Less
Submitted 27 April, 2010; v1 submitted 23 April, 2010;
originally announced April 2010.
-
Limits on inelastic dark matter from ZEPLIN-III
Authors:
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
R. Cashmore,
V. Chepel,
A. Currie,
D. Davidge,
J. Dawson,
T. Durkin,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
A. S. Howard,
A. J. Hughes,
W. G. Jones,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
I. Liubarsky
, et al. (21 additional authors not shown)
Abstract:
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under…
▽ More
We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under standard halo assumptions a small region of parameter space consistent, at 99% CL, with causing the 1.17 ton.year DAMA modulation signal is allowed at 90% CL: it is in the mass range 45-60 GeV with a minimum CL of 88%, again derived from the maximum patch. This is the tightest constraint on that explanation of the DAMA result yet presented using a xenon target.
△ Less
Submitted 1 April, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
Calibration of Photomultiplier Arrays
Authors:
F. Neves,
V. Chepel,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
B. Edwards,
C. Ghag,
M. Horn,
A. J. Hughes,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (9 additional authors not shown)
Abstract:
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields,…
▽ More
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields, etc) are exactly matched between calibration and science acquisitions. This is of particular importance in low background experiments such as ZEPLIN-III, where methods involving the use of external light sources for calibration are severely constrained.
△ Less
Submitted 15 May, 2009;
originally announced May 2009.
-
The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
Authors:
D. Yu. Akimov,
G. J. Alner,
H. M. Araujo,
A. Bewick,
C. Bungau,
A. A. Burenkov,
M. J. Carson,
V. Chepel,
D. Cline,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
C. Chag,
R. J. Hollingworth,
A. S. Howard,
W. G. Jones,
M. Joshi,
J. Kirkpatrick,
A. Kovalenko,
V. A. Kudryavtsev,
I. S. Kuznetsov
, et al. (35 additional authors not shown)
Abstract:
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of…
▽ More
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
△ Less
Submitted 19 May, 2006;
originally announced May 2006.
-
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
Authors:
H. M. Araujo,
D. Yu. Akimov,
G. J. Alner,
A. Bewick,
C. Bungau,
B. Camanzi,
M. J. Carson,
V. Chepel,
H. Chagani,
D. Davidge,
J. C. Davies,
E. Daw,
J. Dawson,
T. Durkin,
B. Edwards,
T. Gamble,
C. Ghag,
R. Hollingworth,
A. S. Howard,
W. G. Jones,
M. Joshi,
J. Kirkpatrick,
A. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko
, et al. (31 additional authors not shown)
Abstract:
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, includ…
▽ More
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.
△ Less
Submitted 9 March, 2006;
originally announced March 2006.
-
Low-Background Experiments with High Pressure Gas Scintillation Proportional Detector
Authors:
D. Yu. Akimov,
A. A. Burenkov,
V. F. Kuzichev,
V. L. Morgunov,
V. N. Solovov
Abstract:
A scintillation proportional counter with wavelength shifting fiber readout filled with Xe or Kr under a pressure of up to 20 atm is proposed for the low-background experiments on search for dark matter of the Universe and 2K-decay of 78 Kr.
A scintillation proportional counter with wavelength shifting fiber readout filled with Xe or Kr under a pressure of up to 20 atm is proposed for the low-background experiments on search for dark matter of the Universe and 2K-decay of 78 Kr.
△ Less
Submitted 16 April, 1997;
originally announced April 1997.
-
Development of High Pressure Xe Scintillation Proportional Counter for Experiments in "Low-Background" Physics
Authors:
D. Yu. Akimov,
A. A Burenkov,
D. L. Churakov,
V. F. Kuzichev,
V. L. Morgunov,
G. N. Smirnov,
V. N. Solovov
Abstract:
Characteristics of a scintillation proportional counter with WLS fiber optics readout is described. The possibility of detection of the proportional scintillation signal produced by the single electron of primary ionization is shown. The counter can be applied for the experiments in "low--background" physics which require a low energy threshold.
Characteristics of a scintillation proportional counter with WLS fiber optics readout is described. The possibility of detection of the proportional scintillation signal produced by the single electron of primary ionization is shown. The counter can be applied for the experiments in "low--background" physics which require a low energy threshold.
△ Less
Submitted 20 March, 1997;
originally announced March 1997.