Skip to main content

Showing 1–33 of 33 results for author: Akimov, D Y

.
  1. arXiv:2403.12645  [pdf, other

    physics.ins-det

    Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant

    Authors: D. Yu. Akimov, I. S. Aleksandrov, F. B. Ata Kurbonova, V. A. Belov, A. I. Bolozdynya, A. V. Etenko, A. V. Galavanov, Yu. V. Gusakov, A. V. Khromov, A. M. Konovalov, V. N. Kornoukhov, A. G. Kovalenko, E. S. Kozlova, Yu. I. Koskin, A. V. Kumpan, A. V. Lukyashin, A. V. Pinchuk, O. E. Razuvaeva, D. G. Rudik, A. V. Shakirov, G. E. Simakov, V. V. Sosnovtsev, A. A. Vasin

    Abstract: RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy recons… ▽ More

    Submitted 15 May, 2024; v1 submitted 19 March, 2024; originally announced March 2024.

  2. arXiv:2311.00870  [pdf, other

    physics.ins-det

    Characterization of the ambient background in the RED-100 experiment location at Kalinin Nuclear Power Plant

    Authors: D. Y. Akimov, I. S. Alexandrov, V. A. Belov, A. I. Bolozdynya, A. V. Etenko, A. V. Galavanov, Yu. V. Gusakov, A. V. Khromov, A. M. Konovalov, V. N. Kornoukhov, A. G. Kovalenko, E. S. Kozlova, A. V. Kumpan, B. O. Lavrov, A. V. Lukyashin, A. V. Pinchuk, O. E. Razuvaeva, D. G. Rudik, A. V. Shakirov, G. E. Simakov, V. V. Sosnovtsev, A. A. Vasin

    Abstract: The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper descr… ▽ More

    Submitted 24 November, 2023; v1 submitted 1 November, 2023; originally announced November 2023.

    Comments: 16 pages, 12 figures, (minor changes in the text for clarity)

  3. The RED-100 experiment

    Authors: D. Yu. Akimov, I. S. Alexandrov, R. R. Alyev, V. A. Belov, A. I. Bolozdynya, A. V. Etenko, A. V. Galavanov, E. M. Glagovsky, Y. V. Gusakov, A. V. Khromov, S. M. Kiselev, A. M. Konovalov, V. N. Kornoukhov, A. G. Kovalenko, E. S. Kozlova, A. V. Kumpan, A. V. Lukyashin, A. V. Pinchuk, O. E. Razuvaeva, D. G. Rudik, A. V. Shakirov, G. E. Simakov, V. V. Sosnovtsev, A. A. Vasin

    Abstract: The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is des… ▽ More

    Submitted 14 November, 2022; v1 submitted 30 September, 2022; originally announced September 2022.

    Comments: 17 pages, 9 figures, submitted to JINST

  4. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  5. arXiv:2006.02506  [pdf, other

    physics.ins-det hep-ex

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, S. Aviles, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame, J. Bensinger , et al. (365 additional authors not shown)

    Abstract: LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent… ▽ More

    Submitted 28 February, 2022; v1 submitted 3 June, 2020; originally announced June 2020.

    Comments: 45 pages (79 inc. tables), 7 figures, 9 tables

    Journal ref: The European Physical Journal C, Volume 80, Article number: 1044 (2020)

  6. arXiv:1910.09124  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The LUX-ZEPLIN (LZ) Experiment

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, A. Alquahtani, S. K. Alsum, T. J. Anderson, N. Angelides, H. M. Araújo, A. Arbuckle, J. E. Armstrong, M. Arthurs, H. Auyeung, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, J. Bang, M. J. Barry, J. Barthel, D. Bauer, P. Bauer, A. Baxter, J. Belle, P. Beltrame , et al. (357 additional authors not shown)

    Abstract: We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n… ▽ More

    Submitted 3 November, 2019; v1 submitted 20 October, 2019; originally announced October 2019.

  7. First ground-level laboratory test of the two-phase xenon emission detector RED-100

    Authors: D. Yu. Akimov, V. A. Belov, A. I. Bolozdynya, Yu. V. Efremenko, A. V. Etenko, A. V. Galavanov, D. V. Gouss, Yu. V. Gusakov, Dj. Ed. Kdib, A. V. Khromov, A. M. Konovalov, V. N. Kornoukhov, A. G. Kovalenko, E. S. Kozlova, A. V. Kumpan, A. V. Lukyashin, Yu. A. Melikyan, V. V. Moramzin, O. E. Razuvaeva, D. G. Rudik, A. V. Shakirov, G. E. Simakov, V. V. Sosnovtsev, Yu. V. Stogov, A. A. Vasin

    Abstract: RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamats… ▽ More

    Submitted 14 October, 2019; originally announced October 2019.

    Comments: 23 pages, 13 figures

  8. Test of SensL SiPM coated with NOL-1 wavelength shifter in liquid xenon

    Authors: D. Yu. Akimov, V. A. Belov, O. V. Borshchev, A. A. Burenkov, Yu. L. Grishkin, A. K. Karelin, A. V. Kuchenkov, A. N. Martemiyanov, S. A. Ponomarenko, G. E. Simakov, V. N. Stekhanov, N. M. Surin, V. S. Timoshin, O. Ya. Zeldovich

    Abstract: A SensL MicroFC-SMT-60035 6x6 mm$^2$ silicon photo-multiplier coated with a NOL-1 wavelength shifter have been tested in the liquid xenon to detect the 175-nm scintillation light. For comparison, a Hamamatsu vacuum ultraviolet sensitive MPPC VUV3 3x3 mm$^2$ was tested under the same conditions. The photodetection efficiency of $13.1 \pm 2.5$% and $6.0 \pm 1.0$%, correspondingly, is obtained.

    Submitted 3 May, 2017; v1 submitted 5 April, 2017; originally announced April 2017.

    Comments: 8 pages, 4 figures

  9. arXiv:1703.09144  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Technical Design Report

    Authors: B. J. Mount, S. Hans, R. Rosero, M. Yeh, C. Chan, R. J. Gaitskell, D. Q. Huang, J. Makkinje, D. C. Malling, M. Pangilinan, C. A. Rhyne, W. C. Taylor, J. R. Verbus, Y. D. Kim, H. S. Lee, J. Lee, D. S. Leonard, J. Li, J. Belle, A. Cottle, W. H. Lippincott, D. J. Markley, T. J. Martin, M. Sarychev, T. E. Tope , et al. (237 additional authors not shown)

    Abstract: In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.

    Submitted 27 March, 2017; originally announced March 2017.

    Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>

    Report number: LBNL-1007256

  10. Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

    Authors: D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, I. J. Arnquist, M. Arthurs, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, J. Belle, P. Beltrame, T. Benson, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. Bolozdynya, B. Boxer, R. Bramante, P. Brás, J. H. Buckley, V. V. Bugaev , et al. (180 additional authors not shown)

    Abstract: The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,… ▽ More

    Submitted 26 September, 2017; v1 submitted 8 February, 2017; originally announced February 2017.

    Comments: 13 pages, 3 figures, accepted for publication in Astroparticle Physics

  11. arXiv:1611.07168  [pdf

    physics.ins-det astro-ph.IM hep-ex

    New method of 85Kr reduction in a noble gas based low-background detector

    Authors: D. Yu. Akimov, A. I. Bolozdynya, A. A. Burenkov, C. Hall, A. G. Kovalenko, V. V. Kuzminov, G. E. Simakov

    Abstract: Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr concentration in such experiments. We propose to augment those separation technologies by first adding to the xenon an 85Kr-free sample of krypton in an amount much lar… ▽ More

    Submitted 22 November, 2016; originally announced November 2016.

    Comments: 8 pages, 5 figures

  12. arXiv:1509.02910  [pdf

    physics.ins-det astro-ph.IM hep-ex

    LUX-ZEPLIN (LZ) Conceptual Design Report

    Authors: The LZ Collaboration, D. S. Akerib, C. W. Akerlof, D. Yu. Akimov, S. K. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, S. Balashov, M. J. Barry, P. Bauer, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, K. E. Boast, A. I. Bolozdynya, E. M. Boulton, R. Bramante, J. H. Buckley, V. V. Bugaev, R. Bunker, S. Burdin, J. K. Busenitz , et al. (170 additional authors not shown)

    Abstract: The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp… ▽ More

    Submitted 23 September, 2015; v1 submitted 9 September, 2015; originally announced September 2015.

    Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors

    Report number: LBNL-190005

  13. Observation of light emission from Hamamatsu R11410-20 photomultiplier tubes

    Authors: D. Yu. Akimov, A. I. Bolozdynya, Yu. V. Efremenko, V. A. Kaplin, A. V. Khromov, Yu. A. Melikyan, V. V. Sosnovtsev

    Abstract: We have shown that high voltage biased Hamamatsu R11410-20 photomultipliers with a dark count rate above 10 kHz emit single photons. The effect has been observed in a few units at room temperature and temperatures reduced down to -60 degrees Celsius. The effect should be taken into account in experiments aimed on search for rare events with small energy depositions in massive liquid xenon detector… ▽ More

    Submitted 28 April, 2015; originally announced April 2015.

    Comments: Submitted to NIM A Letter to the Editor

  14. arXiv:1408.1823  [pdf

    physics.ins-det hep-ex

    Experimental study of ionization yield of liquid xenon for electron recoils in the energy range 2.8 - 80 keV

    Authors: D. Yu. Akimov, V. V. Afanasyev, I. S. Alexandrov, V. A. Belov, A. I. Bolozdynya, A. A. Burenkov, Yu. V. Efremenko, D. A. Egorov, A. V. Etenko, M. A. Gulin, S. V. Ivakhin, V. A. Kaplin, A. K. Karelin, A. V. Khromov, M. A. Kirsanov, S. G. Klimanov, A. S. Kobyakin, A. M. Konovalov, A. G. Kovalenko, A. V. Kuchenkov, A. V. Kumpan, Yu. A. Melikyan, R. I. Nikolaev, D. G. Rudik, V. V. Sosnovtsev , et al. (1 additional authors not shown)

    Abstract: We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement with 37Ar isotope (2.82 keV) that the ionization yield is growing up with the energy decrease in the energy range below ~ 10 keV accordingly to the NEST predicti… ▽ More

    Submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 8 figures

  15. arXiv:1303.7338  [pdf

    physics.ins-det hep-ex

    Two-phase xenon emission detector with electron multiplier and optical readout by multipixel avalanche Geiger photodiodes

    Authors: D. Yu. Akimov, A. V. Akindinov, I. S. Alexandrov, V. A. Belov, A. I. Bolozdynya, A. A. Burenkov, A. F. Buzulutskov, M. V. Danilov, Yu. V. Efremenko, M. A. Kirsanov, A. G. Kovalenko, V. N. Stekhanov

    Abstract: A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was demonstrated.

    Submitted 17 April, 2013; v1 submitted 29 March, 2013; originally announced March 2013.

    Journal ref: JINST 2013

  16. Measurement and simulation of the muon-induced neutron yield in lead

    Authors: L. Reichhart, A. Lindote, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. Bewick, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, V. Francis, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. A. Kudryavtsev, V. N. Lebedenko, M. I. Lopes, R. Luscher, P. Majewski, A. St J. Murphy , et al. (14 additional authors not shown)

    Abstract: A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well… ▽ More

    Submitted 4 November, 2013; v1 submitted 18 February, 2013; originally announced February 2013.

    Comments: 12 pages, 13 figures

    Journal ref: Astroparticle Physics 47 (2013) 67-76

  17. arXiv:1212.1938  [pdf

    physics.ins-det hep-ex nucl-ex

    Perspectives to measure neutrino-nuclear neutral current coherent scattering with two-phase emission detector

    Authors: RED Collaboration, D. Yu. Akimov, I. S. Alexandrov, V. I. Aleshin, V. A. Belov, A. I. Bolozdynya, A. A. Burenkov, A. S. Chepurnov, M. V. Danilov, A. V. Derbin, V. V. Dmitrenko, A. G. Dolgolenko, D. A. Egorov, Yu. V. Efremenko, A. V. Etenko, M. B. Gromov, M. A. Gulin, S. V. Ivakhin, V. A. Kantserov, V. A. Kaplin, A. K. Karelin, A. V. Khromov, M. A. Kirsanov, S. G. Klimanov, A. S. Kobyakin , et al. (21 additional authors not shown)

    Abstract: We propose to detect and to study neutrino neutral current coherent scattering off atomic nuclei with a two-phase emission detector using liquid xenon as a working medium. Expected signals and backgrounds are calculated for two possible experimental sites: Kalinin Nuclear Power Plant in the Russian Federation and Spallation Neutron Source at the Oak Ridge National Laboratory in the USA. Both sites… ▽ More

    Submitted 9 December, 2012; originally announced December 2012.

    Comments: 16 pages, 10 figures, RED collaboration

  18. arXiv:1112.1481  [pdf, ps, other

    physics.ins-det astro-ph.IM physics.med-ph

    Position Reconstruction in a Dual Phase Xenon Scintillation Detector

    Authors: V. N. Solovov, V. A. Belov, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, P. Majewski, A. St J. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (11 additional authors not shown)

    Abstract: We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the… ▽ More

    Submitted 26 September, 2012; v1 submitted 7 December, 2011; originally announced December 2011.

    Comments: 8 pages, 7 figures, in the Conference Record of IEEE NSS 2011, accepted for publication in IEEE Trans. on Nuc. Sci

  19. arXiv:1112.0080  [pdf, ps, other

    physics.ins-det hep-ex

    Performance data from the ZEPLIN-III second science run

    Authors: P. Majewski, V. N. Solovov, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, A. St J. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (10 additional authors not shown)

    Abstract: ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the… ▽ More

    Submitted 30 November, 2011; originally announced December 2011.

    Comments: Submitted to PSD9 conference proceedings

  20. arXiv:1111.2248  [pdf, ps, other

    nucl-ex astro-ph.IM

    Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator

    Authors: L. Reichhart, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, V. Francis, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, P. Majewski, A. St J. Murphy, F. Neves, S. M. Paling , et al. (12 additional authors not shown)

    Abstract: Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (… ▽ More

    Submitted 9 November, 2011; originally announced November 2011.

    Comments: 8 pages, 9 figures

  21. WIMP-nucleon cross-section results from the second science run of ZEPLIN-III

    Authors: D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. Bewick, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, W. G. Jones, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling , et al. (12 additional authors not shown)

    Abstract: We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 ke… ▽ More

    Submitted 16 December, 2011; v1 submitted 21 October, 2011; originally announced October 2011.

  22. arXiv:1110.3056  [pdf, ps, other

    physics.ins-det hep-ex

    Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering

    Authors: E. Santos, B. Edwards, V. Chepel, H. M. Araujo, D. Yu. Akimov, E. J. Barnes, V. A. Belov, A. A. Burenkov, A. Currie, L. DeViveiros, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (12 additional authors not shown)

    Abstract: We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these… ▽ More

    Submitted 13 October, 2011; originally announced October 2011.

  23. arXiv:1106.0808  [pdf, ps, other

    astro-ph.IM physics.ins-det

    ZE3RA: The ZEPLIN-III Reduction and Analysis Package

    Authors: F. Neves, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, P. Majewski, A. St J. Murphy, S. M. Paling, J. Pinto da Cunha, R. Preece , et al. (12 additional authors not shown)

    Abstract: ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d… ▽ More

    Submitted 4 June, 2011; originally announced June 2011.

  24. arXiv:1106.0694  [pdf, ps, other

    physics.ins-det hep-ex

    Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data

    Authors: M. Horn, V. A. Belov, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, A. A. Burenkov, V. Chepel, A. Currie, B. Edwards, C. Ghag, A. Hollingsworth, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha, R. Preece, J. J. Quenby , et al. (11 additional authors not shown)

    Abstract: Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r… ▽ More

    Submitted 17 October, 2011; v1 submitted 3 June, 2011; originally announced June 2011.

    Comments: 7 pages, 7 figures

  25. Radioactivity Backgrounds in ZEPLIN-III

    Authors: H. M. Araujo, D. Yu. Akimov, E. J. Barnes, V. A. Belov, A. Bewick, A. A. Burenkov, V. Chepel. A. Currie, L. DeViveiros, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, P. Majewski, A. StJ. Murphy. F. Neves, S. M. Paling, J. Pinto da Cunha, R. Preece, J. J. Quenby , et al. (10 additional authors not shown)

    Abstract: We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level… ▽ More

    Submitted 12 August, 2011; v1 submitted 18 April, 2011; originally announced April 2011.

    Comments: 12 pages, 5 figures

  26. Performance of the veto detector incorporated into the ZEPLIN-III experiment

    Authors: C. Ghag, D. Yu. Akimov, H. M. Araújo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, L. DeViveiros, B. Edwards, V. Francis, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Lüscher, K. Lyons, P. Majewski, A. St, J. Murphy, F. Neves , et al. (14 additional authors not shown)

    Abstract: The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of… ▽ More

    Submitted 1 May, 2011; v1 submitted 2 March, 2011; originally announced March 2011.

    Journal ref: Astroparticle Physics 35 (2011), pp. 76-86

  27. The ZEPLIN-III Anti-Coincidence Veto Detector

    Authors: D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, V. Chepel, A. Currie, B. Edwards, V. Francis, C. Ghag, A. Hollingsworth, M. Horn, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, K. Lyons, P. Majewski, A. StJ. Murphy, F. Neves, S. M. Paling, J. Pinto da Cunha , et al. (12 additional authors not shown)

    Abstract: The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim… ▽ More

    Submitted 27 April, 2010; v1 submitted 23 April, 2010; originally announced April 2010.

    Journal ref: Astroparticle Physics 34 (2010), pp. 151-163

  28. Limits on inelastic dark matter from ZEPLIN-III

    Authors: D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. Bewick, A. A. Burenkov, R. Cashmore, V. Chepel, A. Currie, D. Davidge, J. Dawson, T. Durkin, B. Edwards, C. Ghag, A. Hollingsworth, M. Horn, A. S. Howard, A. J. Hughes, W. G. Jones, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, I. Liubarsky , et al. (21 additional authors not shown)

    Abstract: We present limits on the WIMP-nucleon cross section for inelastic dark matter derived from the 2008 run of ZEPLIN-III. Cuts, notably on scintillation pulse shape and scintillation-to-ionisation ratio, give a net exposure of 63 kg.days in the range 20-80keV nuclear recoil energy, in which 6 events are observed. Upper limits on signal rate are derived from the maximum empty patch in the data. Under… ▽ More

    Submitted 1 April, 2010; v1 submitted 29 March, 2010; originally announced March 2010.

    Comments: 4 pages, 5 figures. Updated with 1.17 ton.year DAMA results.

    Journal ref: Phys.Lett.B692:180-183,2010

  29. Calibration of Photomultiplier Arrays

    Authors: F. Neves, V. Chepel, D. Yu. Akimov, H. M. Araujo, E. J. Barnes, V. A. Belov, A. A. Burenkov, A. Currie, B. Edwards, C. Ghag, M. Horn, A. J. Hughes, G. E. Kalmus, A. S. Kobyakin, A. G. Kovalenko, V. N. Lebedenko, A. Lindote, M. I. Lopes, R. Luscher, K. Lyons, P. Majewski, A. StJ. Murphy, J. Pinto da Cunha, R. Preece, J. J. Quenby , et al. (9 additional authors not shown)

    Abstract: A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields,… ▽ More

    Submitted 15 May, 2009; originally announced May 2009.

    Comments: 15 pages, 6 figures

    Journal ref: Astropart.Phys.33:13-18,2010

  30. The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning

    Authors: D. Yu. Akimov, G. J. Alner, H. M. Araujo, A. Bewick, C. Bungau, A. A. Burenkov, M. J. Carson, V. Chepel, D. Cline, D. Davidge, J. C. Davies, E. Daw, J. Dawson, T. Durkin, B. Edwards, T. Gamble, C. Chag, R. J. Hollingworth, A. S. Howard, W. G. Jones, M. Joshi, J. Kirkpatrick, A. Kovalenko, V. A. Kudryavtsev, I. S. Kuznetsov , et al. (35 additional authors not shown)

    Abstract: We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of… ▽ More

    Submitted 19 May, 2006; originally announced May 2006.

    Comments: 25 pages, 19 figures. Submitted to Astropart. Phys. Some figures down sampled to reduce size

    Journal ref: Astropart.Phys. 27 (2007) 46-60

  31. The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool

    Authors: H. M. Araujo, D. Yu. Akimov, G. J. Alner, A. Bewick, C. Bungau, B. Camanzi, M. J. Carson, V. Chepel, H. Chagani, D. Davidge, J. C. Davies, E. Daw, J. Dawson, T. Durkin, B. Edwards, T. Gamble, C. Ghag, R. Hollingworth, A. S. Howard, W. G. Jones, M. Joshi, J. Kirkpatrick, A. Kovalenko, V. A. Kudryavtsev, V. N. Lebedenko , et al. (31 additional authors not shown)

    Abstract: We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, includ… ▽ More

    Submitted 9 March, 2006; originally announced March 2006.

    Comments: Submitted to Astroparticle Physics

    Journal ref: Astropart.Phys. 26 (2006) 140-153

  32. arXiv:physics/9704021  [pdf, ps, other

    physics.ins-det astro-ph hep-ex

    Low-Background Experiments with High Pressure Gas Scintillation Proportional Detector

    Authors: D. Yu. Akimov, A. A. Burenkov, V. F. Kuzichev, V. L. Morgunov, V. N. Solovov

    Abstract: A scintillation proportional counter with wavelength shifting fiber readout filled with Xe or Kr under a pressure of up to 20 atm is proposed for the low-background experiments on search for dark matter of the Universe and 2K-decay of 78 Kr.

    Submitted 16 April, 1997; originally announced April 1997.

    Comments: LaTeX 9 pages, 4 figures in EPS format

    Report number: Preprint ITEP 14-97

  33. arXiv:hep-ex/9703011  [pdf, ps, other

    hep-ex astro-ph

    Development of High Pressure Xe Scintillation Proportional Counter for Experiments in "Low-Background" Physics

    Authors: D. Yu. Akimov, A. A Burenkov, D. L. Churakov, V. F. Kuzichev, V. L. Morgunov, G. N. Smirnov, V. N. Solovov

    Abstract: Characteristics of a scintillation proportional counter with WLS fiber optics readout is described. The possibility of detection of the proportional scintillation signal produced by the single electron of primary ionization is shown. The counter can be applied for the experiments in "low--background" physics which require a low energy threshold.

    Submitted 20 March, 1997; originally announced March 1997.

    Comments: LaTeX, 11 pages, 11 eps-figures

    Report number: Preprint ITEP 12-97