-
Study of time and energy resolution of an ultra-compact sampling calorimeter (RADiCAL) module at EM shower maximum over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV
Authors:
Carlos Perez-Lara,
James Wetzel,
Ugur Akgun,
Thomas Anderson,
Thomas Barbera,
Dylan Blend,
Kerem Cankocak,
Salim Cerci,
Nehal Chigurupati,
Bradley Cox,
Paul Debbins,
Max Dubnowski,
Buse Duran,
Gizem Gul Dincer,
Selbi Hatipoglu,
Ilknur Hos,
Bora Isildak,
Colin Jessop,
Ohannes Kamer Koseyan,
Ayben Karasu Uysal,
Reyhan Kurt,
Berkan Kaynak,
Alexander Ledovskoy,
Alexi Mestvirishvili,
Yasar Onel
, et al. (14 additional authors not shown)
Abstract:
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and w…
▽ More
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and wavelength-shifting (WLS) technologies and photosensor, including SiPM and SiPM-like technology. The modules discussed herein consist of alternating layers of very dense (W) absorber and scintillating crystal (LYSO:Ce) plates, assembled to a depth of 25 $X_0$. The scintillation signals produced by the EM showers in the region of EM shower maximum (shower max) are transmitted to SiPM located at the upstream and downstream ends of the modules via quartz capillaries which penetrate the full length of the module. The capillaries contain DSB1 organic plastic WLS filaments positioned within the region of shower max, where the shower energy deposition is greatest, and fused with quartz rod elsewhere. The wavelength shifted light from this spatially-localized shower max region is then propagated to the photosensors. This paper presents the results of an initial measurement of the time resolution of a RADiCAL module over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV using the H2 electron beam at CERN. The data indicate an energy dependence of the time resolution that follows the functional form: $σ_{t} = a/\sqrt{E} \oplus b$, where a = 256 $\sqrt{GeV}$~ps and b = 17.5 ps. The time resolution measured at the highest electron beam energy for which data was currently recorded (150 GeV) was found to be $σ_{t}$ = 27 ps.
△ Less
Submitted 3 January, 2024;
originally announced January 2024.
-
Proton stop** power images from Monte Carlo simulated dual-energy CT scans
Authors:
Adam Zieser,
Ugur Akgun,
Yasar Onel
Abstract:
We test the feasibility of calculating proton stop** power (SP) from a set of virtual monochromatic (VM) CT images, created with Monte Carlo-generated CT scans, using a dual-energy CT-to-SP procedure. The Monte Carlo CT simulations, with 70 and 150 kVp spectra, were modeled on the x-ray tube parameters of the SOMATOM Force dual-source DECT scanner and the Gammex RMI 467 tissue calibration phanto…
▽ More
We test the feasibility of calculating proton stop** power (SP) from a set of virtual monochromatic (VM) CT images, created with Monte Carlo-generated CT scans, using a dual-energy CT-to-SP procedure. The Monte Carlo CT simulations, with 70 and 150 kVp spectra, were modeled on the x-ray tube parameters of the SOMATOM Force dual-source DECT scanner and the Gammex RMI 467 tissue calibration phantom. Reconstructed SP images were created with two VM x-ray images, and the monochromatic energy pairs were chosen to minimize the SP residual errors using the root-mean-squared-error (RMSE). The contrast of phantom inserts has also been examined, in addition to relative errors of the average reconstructed insert values (which are calculated using the known electron densities and chemical compositions of each material, provided by the manufacturer). Results were also compared to a similar dual-energy-based SP conversion procedure for comparison. Modest reductions in errors and noise were seen in almost all inserts in both low- and high-density configurations of the phantom, with a visible reduction in beam-hardening streaking artifacts. Our Monte Carlo simulated DECT scans confirm the feasibility of previously proposed methods of DECT-based $ S(ρ_e, Z) $-determination. By utilizing VM images and only optimizing the RMSE over specific inserts, the residual error across the most vital bodily tissues may be reduced when extremely low- or high-density tissues are known to be present.
△ Less
Submitted 21 June, 2022;
originally announced June 2022.
-
Reconstructed pCT Images Using Monte Carlo Simulations of a Scintillating Glass Detector
Authors:
Adam Zieser,
Ugur Akgun,
Yasar Onel
Abstract:
The high cost and low image quality traditionally associated with proton computed tomography (pCT) have prevented it from seeing significant use in clinical settings. A cheap, compact, high-density scintillating glass detector capable of being attached to existing proton therapy gantries may help address these concerns. The design of the detector allows for use in conjunction with single-proton co…
▽ More
The high cost and low image quality traditionally associated with proton computed tomography (pCT) have prevented it from seeing significant use in clinical settings. A cheap, compact, high-density scintillating glass detector capable of being attached to existing proton therapy gantries may help address these concerns. The design of the detector allows for use in conjunction with single-proton counting reconstruction algorithms, as well as beam-based algorithms that do not resolve individual protons within an accelerator bunch. This study presents quantitative reconstructed images of proton stop** power from Monte Carlo generated pCT scans using the radiation transport code MCNP6, demonstrating the feasibility of proton imaging using this detector design. Relative error and contrast have been examined and compared for images reconstructed using two reconstruction algorithms: a standard filtered backprojection algorithm to act as a benchmark, and a variant of a pCT algorithm which utilizes the concept of distance-driven binning.
△ Less
Submitted 20 June, 2022;
originally announced June 2022.
-
KML: Using Machine Learning to Improve Storage Systems
Authors:
Ibrahim Umit Akgun,
Ali Selman Aydin,
Andrew Burford,
Michael McNeill,
Michael Arkhangelskiy,
Aadil Shaikh,
Lukas Velikov,
Erez Zadok
Abstract:
Operating systems include many heuristic algorithms designed to improve overall storage performance and throughput. Because such heuristics cannot work well for all conditions and workloads, system designers resorted to exposing numerous tunable parameters to users -- thus burdening users with continually optimizing their own storage systems and applications. Storage systems are usually responsibl…
▽ More
Operating systems include many heuristic algorithms designed to improve overall storage performance and throughput. Because such heuristics cannot work well for all conditions and workloads, system designers resorted to exposing numerous tunable parameters to users -- thus burdening users with continually optimizing their own storage systems and applications. Storage systems are usually responsible for most latency in I/O-heavy applications, so even a small latency improvement can be significant. Machine learning (ML) techniques promise to learn patterns, generalize from them, and enable optimal solutions that adapt to changing workloads. We propose that ML solutions become a first-class component in OSs and replace manual heuristics to optimize storage systems dynamically. In this paper, we describe our proposed ML architecture, called KML. We developed a prototype KML architecture and applied it to two case studies: optimizing readahead and NFS read-size values. Our experiments show that KML consumes less than 4KB of dynamic kernel memory, has a CPU overhead smaller than 0.2%, and yet can learn patterns and improve I/O throughput by as much as 2.3x and 15x for two case studies -- even for complex, never-seen-before, concurrently running mixed workloads on different storage devices.
△ Less
Submitted 25 January, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Measurements of the Rate Capability of Various Resistive Plate Chambers
Authors:
M. Affatigato,
U. Akgun,
B. Bilki,
F. Corriveau,
B. Freund,
N. Johnson,
C. Neubueser,
Y. Onel,
J. Repond,
L. Xia
Abstract:
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in their construction. This paper reports on measurements of the performance of three different glass RPC designs featuring a different total resistance of the re…
▽ More
Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in their construction. This paper reports on measurements of the performance of three different glass RPC designs featuring a different total resistance of the resistive plates. The measurements were performed with 120 GeV protons at varying beam intensities
△ Less
Submitted 7 September, 2015; v1 submitted 24 July, 2015;
originally announced July 2015.
-
The transverse momentum dependence of charged kaon Bose-Einstein correlations in the SELEX experiment
Authors:
SELEX Collaboration,
G. A. Nigmatkulov,
A. K. Ponosov,
U. Akgun,
G. Alkhazov,
J. Amaro-Reyes,
A. Asratyan,
A. G. Atamantchouk,
A. S. Ayan,
M. Y. Balatz,
A. Blanco-Covarrubias,
N. F. Bondar,
P. S. Cooper,
L. J. Dauwe,
G. V. Davidenko,
U. Dersch,
A. G. Dolgolenko,
G. B. Dzyubenko,
R. Edelstein,
L. Emediato,
A. M. F. Endler,
J. Engelfried,
I. Eschrich,
C. O. Escobar,
N. Estrada
, et al. (79 additional authors not shown)
Abstract:
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlatio…
▽ More
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlation strength, $λ$, are extracted. The analysis shows a decrease of the source radii with increasing kaon transverse pair momentum for all beam types.
△ Less
Submitted 14 November, 2015; v1 submitted 18 January, 2015;
originally announced January 2015.
-
Measurement of Charged Pion Production Yields off the NuMI Target
Authors:
J. M. Paley,
M. D. Messier,
R. Raja,
U. Akgun,
D. M. Asner,
G. Aydin,
W. Baker,
P. D. Barnes, Jr.,
T. Bergfeld,
L. Beverly,
V. Bhatnagar,
B. Choudhary,
E. C. Dukes,
F. Duru,
G. J. Feldman,
A. Godley,
N. Graf,
J. Gronberg,
E. Gulmez,
Y. O. Gunaydin,
H. R. Gustafson,
E. P. Hartouni,
P. Hanlet,
M. Heffner,
D. M. Kaplan
, et al. (31 additional authors not shown)
Abstract:
The fixed-target MIPP experiment, Fermilab E907, was designed to measure the production of hadrons from the collisions of hadrons of momenta ranging from 5 to 120 GeV/c on a variety of nuclei. These data will generally improve the simulation of particle detectors and predictions of particle beam fluxes at accelerators. The spectrometer momentum resolution is between 3 and 4%, and particle identifi…
▽ More
The fixed-target MIPP experiment, Fermilab E907, was designed to measure the production of hadrons from the collisions of hadrons of momenta ranging from 5 to 120 GeV/c on a variety of nuclei. These data will generally improve the simulation of particle detectors and predictions of particle beam fluxes at accelerators. The spectrometer momentum resolution is between 3 and 4%, and particle identification is performed for particles ranging between 0.3 and 80 GeV/c using $dE/dx$, time-of-flight and Cherenkov radiation measurements. MIPP collected $1.42 \times10^6$ events of 120 GeV Main Injector protons striking a target used in the NuMI facility at Fermilab. The data have been analyzed and we present here charged pion yields per proton-on-target determined in bins of longitudinal and transverse momentum between 0.5 and 80 GeV/c, with combined statistical and systematic relative uncertainties between 5 and 10%.
△ Less
Submitted 23 April, 2014;
originally announced April 2014.
-
Forward Neutron Production at the Fermilab Main Injector
Authors:
T. S. Nigmanov,
D. Rajaram,
M. J. Longo,
U. Akgun,
G. Aydin,
W. Baker,
P. D. Barnes, Jr.,
T. Bergfeld,
A. Bujak,
D. Carey,
E. C. Dukes,
F. Duru,
G. J. Feldman,
A. Godley,
E. Gülmez,
Y. O. Günaydin,
N. Graf,
H. R. Gustafson,
L. Gutay,
E. Hartouni,
P. Hanlet,
M. Heffner,
C. Johnstone,
D. M. Kaplan,
O. Kamaev
, et al. (28 additional authors not shown)
Abstract:
We have measured cross sections for forward neutron production from a variety of targets using proton beams from the Fermilab Main Injector. Measurements were performed for proton beam momenta of 58 GeV/c, 84 GeV/c, and 120 GeV/c. The cross section dependence on the atomic weight (A) of the targets was found to vary as $A^(alpha)$ where $α$ is $0.46\pm0.06$ for a beam momentum of 58 GeV/c and 0.54…
▽ More
We have measured cross sections for forward neutron production from a variety of targets using proton beams from the Fermilab Main Injector. Measurements were performed for proton beam momenta of 58 GeV/c, 84 GeV/c, and 120 GeV/c. The cross section dependence on the atomic weight (A) of the targets was found to vary as $A^(alpha)$ where $α$ is $0.46\pm0.06$ for a beam momentum of 58 GeV/c and 0.54$\pm$0.05 for 120 GeV/c. The cross sections show reasonable agreement with FLUKA and DPMJET Monte Carlos. Comparisons have also been made with the LAQGSM Monte Carlo.
△ Less
Submitted 3 December, 2010; v1 submitted 29 October, 2010;
originally announced October 2010.
-
Charged Kaon Mass Measurement using the Cherenkov Effect
Authors:
The MIPP Collaboration,
N. Graf,
A. Lebedev,
R. J. Abrams,
U. Akgun,
G. Aydin,
W. Baker,
P. D. Barnes Jr.,
T. Bergfeld,
L. Beverly,
A. Bujak,
D. Carey,
C. Dukes,
F. Duru,
G. J. Feldman,
A. Godley,
E. Gülmez,
Y. O. Günaydın,
H. R. Gustafson,
L. Gutay,
E. Hartouni,
P. Hanlet,
S. Hansen,
M. Heffner,
C. Johnstone
, et al. (38 additional authors not shown)
Abstract:
The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 ppm and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass measurement using the measurement of Cherenkov light from a narrow-band beam of kaons, pions, and protons. This technique was demonstrated using data taken opportu…
▽ More
The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 ppm and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass measurement using the measurement of Cherenkov light from a narrow-band beam of kaons, pions, and protons. This technique was demonstrated using data taken opportunistically by the Main Injector Particle Production experiment at Fermi National Accelerator Laboratory which recorded beams of protons, kaons, and pions ranging in momentum from +37 GeV/c to +63 GeV/c. The measured value is 491.3 +/- 1.7 MeV/c^2, which is within 1.4 sigma of the world average. An improvement of two orders of magnitude in precision would make this technique useful for resolving the ambiguity in the X-ray data and may be achievable in a dedicated experiment.
△ Less
Submitted 4 January, 2010; v1 submitted 4 September, 2009;
originally announced September 2009.