-
aDWI-BIDS: an extension to the brain imaging data structure for advanced diffusion weighted imaging
Authors:
James Gholam,
Filip Szczepankiewicz,
Chantal M. W. Tax,
Lars Mueller,
Emre Kopanoglu,
Markus Nilsson,
Santiago Aja-Fernandez,
Matt Griffin,
Derek K. Jones,
Leandro Beltrachini
Abstract:
Diffusion weighted imaging techniques permit us to infer microstructural detail in biological tissue in vivo and noninvasively. Modern sequences are based on advanced diffusion encoding schemes, allowing probing of more revealing measures of tissue microstructure than the standard apparent diffusion coefficient or fractional anisotropy. Though these methods may result in faster or more revealing a…
▽ More
Diffusion weighted imaging techniques permit us to infer microstructural detail in biological tissue in vivo and noninvasively. Modern sequences are based on advanced diffusion encoding schemes, allowing probing of more revealing measures of tissue microstructure than the standard apparent diffusion coefficient or fractional anisotropy. Though these methods may result in faster or more revealing acquisitions, they generally demand prior knowledge of sequence-specific parameters for which there is no accepted sharing standard. Here, we present a metadata labelling scheme suitable for the needs of developers and users within the diffusion neuroimaging community alike: a lightweight, unambiguous parametric map relaying acqusition parameters. This extensible scheme supports a wide spectrum of diffusion encoding methods, from single diffusion encoding to highly complex sequences involving arbitrary gradient waveforms. Built under the brain imaging data structure (BIDS), it allows storage of advanced diffusion MRI data comprehensively alongside any other neuroimaging information, facilitating processing pipelines and multimodal analyses. We illustrate the usefulness of this BIDS-extension with a range of example data, and discuss the extension's impact on pre- and post-processing software.
△ Less
Submitted 12 April, 2021; v1 submitted 26 March, 2021;
originally announced March 2021.
-
Q-space quantitative diffusion MRI measures using a stretched-exponential representation
Authors:
Tomasz Pieciak,
Maryam Afzali,
Fabian Bogusz,
Aja-Fernández,
Derek K. Jones
Abstract:
Diffusion magnetic resonance imaging (dMRI) is a relatively modern technique used to study tissue microstructure in a non-invasive way. Non-Gaussian diffusion representation is related to the restricted diffusion and can provide information about the underlying tissue properties. In this paper, we analytically derive $n$-th order statistics of the signal considering a stretched-exponential represe…
▽ More
Diffusion magnetic resonance imaging (dMRI) is a relatively modern technique used to study tissue microstructure in a non-invasive way. Non-Gaussian diffusion representation is related to the restricted diffusion and can provide information about the underlying tissue properties. In this paper, we analytically derive $n$-th order statistics of the signal considering a stretched-exponential representation of the diffusion. Then, we retrieve the Q-space quantitative measures such as the Return-To-the-Origin Probability (RTOP), Q-space mean square displacement (QMSD), Q-space mean fourth-order displacement (QMFD). The stretched-exponential representation enables the handling of the diffusion contributions from a higher $b$-value regime under a non-Gaussian assumption, which can be useful in diagnosing or prognosis of neurodegenerative diseases in the early stages. Numerical implementation of the method is freely available at https://github.com/TPieciak/Stretched.
△ Less
Submitted 15 September, 2020;
originally announced September 2020.
-
Simultaneous imaging of hard and soft biological tissues in a low-field dental MRI scanner
Authors:
J. M. Algarín,
E. Díaz-Caballero,
J. Borreguero,
F. Galve,
D. Grau-Ruiz,
J. P. Rigla,
R. Bosch,
J. M. González,
E. Pallás,
M. Corberán,
C. Gramage,
S. Aja-Fernández,
A. Ríos,
J. M. Benlloch,
J. Alonso
Abstract:
Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some medical applications, such as dentistry, continues to be limited. Here, we present three-dimensional reconstructions of ex-vivo human teeth, as well as a rabbit head…
▽ More
Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some medical applications, such as dentistry, continues to be limited. Here, we present three-dimensional reconstructions of ex-vivo human teeth, as well as a rabbit head and part of a cow femur, all obtained at a field strength of only 260 mT. These images are the first featuring soft and hard tissues simultaneously at sub-Tesla fields, and they have been acquired in a home-made, special-purpose, pre-medical MRI scanner designed with the goal of demonstrating dental imaging at low field settings. We encode spatial information with two variations of zero-echo time (ZTE) pulse sequences: Pointwise-Encoding Time reduction with Radial Acquisition (PETRA) and a new sequence we have called Double Radial Non-Stop Spin Echo (DRaNSSE), which we find to perform better than the former. For image reconstruction we employ Algebraic Reconstruction Techniques (ART) as well as standard Fourier methods. A noise analysis of the resulting images shows that ART reconstructions exhibit a higher signal to noise ratio with a more homogeneous noise distribution.
△ Less
Submitted 4 May, 2020;
originally announced May 2020.
-
Computation of Exact g-Factor Maps in 3D GRAPPA Reconstructions
Authors:
Iñaki Rabanillo,
Ante Zhu,
Santiago Aja-Fernández,
Carlos Alberola-López,
Diego Hernando
Abstract:
Purpose: To characterize the noise distributions in 3D-MRI accelerated acquisitions reconstructed with GRAPPA using an exact noise propagation analysis that operates directly in k--space.
Theory and Methods: We exploit the extensive symmetries and separability in the reconstruction steps to account for the correlation between all the acquired k-space samples. Monte Carlo simulations and multi-re…
▽ More
Purpose: To characterize the noise distributions in 3D-MRI accelerated acquisitions reconstructed with GRAPPA using an exact noise propagation analysis that operates directly in k--space.
Theory and Methods: We exploit the extensive symmetries and separability in the reconstruction steps to account for the correlation between all the acquired k-space samples. Monte Carlo simulations and multi-repetition phantom experiments were conducted to test both the accuracy and feasibility of the proposed method; an in-vivo experiment was performed to assess the applicability of our method to clinical scenarios.
Results: Our theoretical derivation shows that the direct k-space analysis renders an exact noise characterization under the assumptions of stationarity and uncorrelation in the original k-space. Simulations and phantom experiments provide empirical support to the theoretical proof. Finally, the in-vivo experiment demonstrates the ability of the proposed method to assess the impact of the sub-sampling pattern on the overall noise behavior.
Conclusions: By operating directly in the k-space, the proposed method is able to provide an exact characterization of noise for any Cartesian pattern sub-sampled along the two phase-encoding directions. Exploitation of the symmetries and separability into independent blocks through the image reconstruction procedure allows us to overcome the computational challenges related to the very large size of the covariance matrices involved.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
Exact Calculation of Noise Maps and g-Factor in GRAPPA using a k-space Analysis
Authors:
Iñaki Rabanillo,
Santiago Aja-Fernández,
Carlos Alberola-López,
Diego Hernando
Abstract:
Noise characterization in MRI has multiple applications, including quality assurance and protocol optimization. It is particularly important in the presence of parallel imaging acceleration, where the noise distribution can contain severe spatial heterogeneities. If the parallel imaging reconstruction is a linear process, an exact noise analysis is possible by taking into account the correlations…
▽ More
Noise characterization in MRI has multiple applications, including quality assurance and protocol optimization. It is particularly important in the presence of parallel imaging acceleration, where the noise distribution can contain severe spatial heterogeneities. If the parallel imaging reconstruction is a linear process, an exact noise analysis is possible by taking into account the correlations between all the samples involved. However, for k-space based techniques like GRAPPA, the exact analysis has been considered computationally prohibitive due to the very large size of the noise covariance matrices required to characterize the noise propagation from k-space to image-space. Previous methods avoid this computational burden by approximating the GRAPPA reconstruction as a pixel-wise linear operation performed in the image-space. However, these methods are not exact in the presence of non-uniform k-space undersampling (e.g.: containing a calibration region). For this reason, in this work we develop an exact characterization of the noise distribution for self-calibrated parallel imaging in the presence of arbitrary Cartesian undersampling patterns. By exploiting the symmetries and separability in the noise propagation process, the proposed method is computationally efficient and does not require large matrices. In this manuscript, we present the proposed noise characterization method and compare it to previous techniques using Monte-Carlo simulations as well as phantom acquisitions.
△ Less
Submitted 25 October, 2016;
originally announced October 2016.
-
Spherical deconvolution of multichannel diffusion MRI data with non-Gaussian noise models and spatial regularization
Authors:
Erick J. Canales-Rodríguez,
Alessandro Daducci,
Stamatios N. Sotiropoulos,
Emmanuel Caruyer,
Santiago Aja-Fernández,
Joaquim Radua,
Jesús María Yurramendi Mendizabal,
Yasser Iturria-Medina,
Lester Melie-García,
Yasser Alemán-Gómez,
Jean-Philippe Thiran,
Salvador Sarró,
Edith Pomarol-Clotet,
Raymond Salvador
Abstract:
Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods fo…
▽ More
Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods for multichannel signal combination lead to Rician and noncentral Chi noise distributions. Here we develop a Robust and Unbiased Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to deal with realistic MRI noise, based on a Richardson-Lucy (RL) algorithm adapted to Rician and noncentral Chi likelihood models. To quantify the benefits of using proper noise models, RUMBA-SD was compared with dRL-SD, a well-established method based on the RL algorithm for Gaussian noise. Another aim of the study was to quantify the impact of including a total variation (TV) spatial regularization term in the estimation framework. To do this, we developed TV spatially-regularized versions of both RUMBA-SD and dRL-SD algorithms. The evaluation was performed by comparing various quality metrics on 132 three-dimensional synthetic phantoms involving different inter-fiber angles and volume fractions, which were contaminated with noise mimicking patterns generated by data processing in multichannel scanners. The results demonstrate that the inclusion of proper likelihood models leads to an increased ability to resolve fiber crossings with smaller inter-fiber angles and to better detect non-dominant fibers. The inclusion of TV regularization dramatically improved the resolution power of both techniques. The above findings were also verified in brain data.
△ Less
Submitted 8 October, 2015; v1 submitted 23 October, 2014;
originally announced October 2014.
-
Statistical Noise Analysis in SENSE Parallel MRI
Authors:
Santiago Aja-Fernandez,
Gonzalo Vegas-Sanchez-Ferrero,
Antonio Trsitan-Vega
Abstract:
A complete first and second order statistical characterization of noise in SENSE reconstructed data is proposed. SENSE acquisitions have usually been modeled as Rician distributed, since the data reconstruction takes place into the spatial domain, where Gaussian noise is assumed. However, this model just holds for the first order statistics and obviates other effects induced by coils correlations…
▽ More
A complete first and second order statistical characterization of noise in SENSE reconstructed data is proposed. SENSE acquisitions have usually been modeled as Rician distributed, since the data reconstruction takes place into the spatial domain, where Gaussian noise is assumed. However, this model just holds for the first order statistics and obviates other effects induced by coils correlations and the reconstruction interpolation. Those effects are properly taken into account in this study, in order to fully justify a final SENSE noise model. As a result, some interesting features of the reconstructed image arise: (1) There is a strong correlation between adjacent lines. (2) The resulting distribution is non-stationary and therefore the variance of noise will vary from point to point across the image. Closed equations for the calculation of the variance of noise and the correlation coefficient between lines are proposed. The proposed model is totally compatible with g-factor formulations.
△ Less
Submitted 17 February, 2014;
originally announced February 2014.