Xenon purity analysis for EXO-200 via mass spectrometry
Authors:
A. Dobi,
C. Hall,
S. Slutsky,
Y. -R. Yen,
B. Aharmin,
M. Auger,
P. S. Barbeau,
C. Benitez-Medina,
M. Breidenbach,
B. Cleveland,
R. Conley,
J. Cook,
S. Cook,
I. Counts,
W. Craddock,
T. Daniels,
C. G. Davis,
J. Davis,
R. deVoe,
M. Dixit,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (51 additional authors not shown)
Abstract:
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We ha…
▽ More
We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivity of the spectrometer is enhanced by several orders of magnitude by the presence of a liquid nitrogen cold trap, and many impurity species of interest can be detected at the level of one part-per-billion or better. We have used the technique to screen the EXO-200 xenon before, during, and after its use in our detector, and these measurements have proven useful. This is the first application of the cold trap mass spectrometry technique to an operating physics experiment.
△ Less
Submitted 5 September, 2011;
originally announced September 2011.
-
A xenon gas purity monitor for EXO
Authors:
EXO Collaboration,
A. Dobi,
C. Hall,
S. Herrin,
A. Odian,
C. Y. Prescott,
P. C. Rowson,
N. Ackerman,
B. Aharmin,
M. Auger,
P. S. Barbeau,
K. Barry,
C. Benitez-Medina,
M. Breidenbach,
S. Cook,
I. Counts,
T. Daniels,
R. DeVoe,
M. J. Dolinski,
K. Donato,
W. Fairbank Jr.,
J. Farine,
G. Giroux,
R. Gornea,
K. Graham
, et al. (35 additional authors not shown)
Abstract:
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tu…
▽ More
We discuss the design, operation, and calibration of two versions of a xenon gas purity monitor (GPM) developed for the EXO double beta decay program. The devices are sensitive to concentrations of oxygen well below 1 ppb at an ambient gas pressure of one atmosphere or more. The theory of operation of the GPM is discussed along with the interactions of oxygen and other impurities with the GPM's tungsten filament. Lab tests and experiences in commissioning the EXO-200 double beta decay experiment are described. These devices can also be used on other noble gases.
△ Less
Submitted 9 June, 2011;
originally announced June 2011.
-
A simple radionuclide-driven single-ion source
Authors:
M. Montero Díez,
K. Twelker,
W. Fairbank Jr.,
G. Gratta,
P. S. Barbeau,
K. Barry,
R. DeVoe,
M. J. Dolinski,
M. Green,
F. LePort,
A. R. Müller,
R. Neilson,
K. O'Sullivan,
N. Ackerman,
B. Aharmin,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
S. Cook,
T. Daniels,
K. Donato,
J. Farine,
G. Giroux,
R. Gornea
, et al. (32 additional authors not shown)
Abstract:
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detect…
▽ More
We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon α-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.
△ Less
Submitted 19 August, 2010;
originally announced August 2010.