The ArTéMiS wide-field submillimeter camera: preliminary on-sky performances at 350 microns
Authors:
Vincent Reveret,
Philippe André,
Jean Le Pennec,
Michel Talvard,
Patrick Agnèse,
Agnès Arnaud,
Laurent Clerc,
Carlos de Breuck,
Jean-Charles Cigna,
Cyrille Delisle,
Eric Doumayrou,
Lionel Duband,
Didier Dubreuil,
Luc Dumaye,
Eric Ercolani,
Pascal Gallais,
Elodie Groult,
Thierry Jourdan,
Bernadette Leriche,
Bruno Maffei,
Michel Lortholary,
Jérôme Martignac,
Wilfried Rabaud,
Johan Relland,
Louis Rodriguez
, et al. (2 additional authors not shown)
Abstract:
ArTeMiS is a wide-field submillimeter camera operating at three wavelengths simultaneously (200, 350 and 450 microns). A preliminary version of the instrument equipped with the 350 microns focal plane, has been successfully installed and tested on APEX telescope in Chile during the 2013 and 2014 austral winters. This instrument is developed by CEA (Saclay and Grenoble, France), IAS (France) and Un…
▽ More
ArTeMiS is a wide-field submillimeter camera operating at three wavelengths simultaneously (200, 350 and 450 microns). A preliminary version of the instrument equipped with the 350 microns focal plane, has been successfully installed and tested on APEX telescope in Chile during the 2013 and 2014 austral winters. This instrument is developed by CEA (Saclay and Grenoble, France), IAS (France) and University of Manchester (UK) in collaboration with ESO. We introduce the mechanical and optical design, as well as the cryogenics and electronics of the ArTeMiS camera. ArTeMiS detectors are similar to the ones developed for the Herschel PACS photometer but they are adapted to the high optical load encountered at APEX site. Ultimately, ArTeMiS will contain 4 sub-arrays at 200 microns and 2x8 sub-arrays at 350 and 450 microns. We show preliminary lab measurements like the responsivity of the instrument to hot and cold loads illumination and NEP calculation. Details on the on-sky commissioning runs made in 2013 and 2014 at APEX are shown. We used planets (Mars, Saturn, Uranus) to determine the flat-field and to get the flux calibration. A pointing model was established in the first days of the runs. The average relative pointing accuracy is 3 arcsec. The beam at 350 microns has been estimated to be 8.5 arcsec, which is in good agreement with the beam of the 12 m APEX dish. Several observing modes have been tested, like On-The-Fly for beam-maps or large maps, spirals or raster of spirals for compact sources. With this preliminary version of ArTeMiS, we concluded that the map** speed is already more than 5 times better than the previous 350 microns instrument at APEX. The median NEFD at 350 microns is 600 mJy.s1/2, with best values at 300 mJy.s1/2. The complete instrument with 5760 pixels and optimized settings will be installed during the first half of 2015.
△ Less
Submitted 9 July, 2014;
originally announced July 2014.
-
Enhancing the spectral response of filled bolometer arrays for submillimeter astronomy
Authors:
Vincent Revéret,
Louis Rodriguez,
Patrick Agnèse
Abstract:
The future missions for astrophysical studies in the submillimeter region will need detectors with very high sensitivity and large field of view. Bolometer arrays can fulfill these requirements over a very broad band. We describe a technique that enables bolometer arrays that use quarter wave cavities to have a high spectral response over most of the submillimeter band. This technique is based on…
▽ More
The future missions for astrophysical studies in the submillimeter region will need detectors with very high sensitivity and large field of view. Bolometer arrays can fulfill these requirements over a very broad band. We describe a technique that enables bolometer arrays that use quarter wave cavities to have a high spectral response over most of the submillimeter band. This technique is based on the addition on the front of the array of an anti-reflecting dielectric layer. The optimum parameters (layer thickness and distance to the array) are determined by a 2D analytic code. This general principle is applied to the case of the Herschel PACS bolometers (optimized for the 60 - 210 micron band). As an example, we demonstrate experimentally that a PACS array covered by a 138 micron thick silicon layer can improve the spectral response by a factor 1.7 in the 450 micron band.
△ Less
Submitted 4 November, 2010;
originally announced November 2010.
-
CEA Bolometer Arrays: the First Year in Space
Authors:
Nicolas Billot,
M. Sauvage,
L. Rodriguez,
B. Horeau,
C. Kiss,
H. Aussel,
K. Okumura,
O. Boulade,
B. Altieri,
A. Poglitsch,
P. Agnese
Abstract:
The CEA/LETI and CEA/SAp started the development of far-infrared filled bolometer arrays for space applications over a decade ago. The unique design of these detectors makes possible the assembling of large focal planes comprising thousands of bolometers running at 300 mK with very low power dissipation. Ten arrays of 16x16 pixels were thoroughly tested on the ground, and integrated in the Hersche…
▽ More
The CEA/LETI and CEA/SAp started the development of far-infrared filled bolometer arrays for space applications over a decade ago. The unique design of these detectors makes possible the assembling of large focal planes comprising thousands of bolometers running at 300 mK with very low power dissipation. Ten arrays of 16x16 pixels were thoroughly tested on the ground, and integrated in the Herschel/PACS instrument before launch in May 2009. These detectors have been successfully commissioned and are now operating in their nominal environment at the second Lagrangian point of the Earth-Sun system. In this paper we briefly explain the functioning of CEA bolometer arrays, and we present the properties of the detectors focusing on their noise characteristics, the effect of cosmic rays on the signal, the repeatability of the measurements, and the stability of the system.
△ Less
Submitted 13 July, 2010;
originally announced July 2010.
-
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory
Authors:
A. Poglitsch,
C. Waelkens,
N. Geis,
H. Feuchtgruber,
B. Vandenbussche,
L. Rodriguez,
O. Krause,
E. Renotte,
C. van Hoof,
P. Saraceno,
J. Cepa,
F. Kerschbaum,
P. Agnese,
B. Ali,
B. Altieri,
P. Andreani,
J. -L. Augueres,
Z. Balog,
L. Barl,
O. H. Bauer,
N. Belbachir,
M. Benedettini,
N. Billot,
O. Boulade,
H. Bischof
, et al. (58 additional authors not shown)
Abstract:
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210…
▽ More
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210μ m wavelength regime. In photometry mode, it simultaneously images two bands, 60-85μ m or 85-125μ\m and 125-210μ m, over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47"x47", resolved into 5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral resolution of ~175km/s. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the Performance Verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions.
△ Less
Submitted 20 May, 2010; v1 submitted 10 May, 2010;
originally announced May 2010.
-
The Herschel/PACS 2560 bolometers imaging camera
Authors:
Nicolas Billot,
Patrick Agnese,
Jean-Louis Augueres,
Alain Beguin,
Andre Bouere,
Olivier Boulade,
Christophe Cara,
Christelle Cloue,
Eric Doumayrou,
Lionel Duband,
Benoit Horeau,
Isabelle Le Mer,
Jean Le Pennec,
Jerome Martignac,
Koryo Okumura,
Vincent Reveret,
Marc Sauvage,
Francois Simoens,
Laurent Vigroux
Abstract:
The development program of the flight model imaging camera for the PACS instrument on-board the Herschel spacecraft is nearing completion. This camera has two channels covering the 60 to 210 microns wavelength range. The focal plane of the short wavelength channel is made of a mosaic of 2x4 3-sides buttable bolometer arrays (16x16 pixels each) for a total of 2048 pixels, while the long wavelengt…
▽ More
The development program of the flight model imaging camera for the PACS instrument on-board the Herschel spacecraft is nearing completion. This camera has two channels covering the 60 to 210 microns wavelength range. The focal plane of the short wavelength channel is made of a mosaic of 2x4 3-sides buttable bolometer arrays (16x16 pixels each) for a total of 2048 pixels, while the long wavelength channel has a mosaic of 2 of the same bolometer arrays for a total of 512 pixels. The 10 arrays have been fabricated, individually tested and integrated in the photometer. They represent the first filled arrays of fully collectively built bolometers with a cold multiplexed readout, allowing for a properly sampled coverage of the full instrument field of view. The camera has been fully characterized and the ground calibration campaign will take place after its delivery to the PACS consortium in mid 2006. The bolometers, working at a temperature of 300 mK, have a NEP close to the BLIP limit and an optical bandwidth of 4 to 5 Hz that will permit the map** of large sky areas. This paper briefly presents the concept and technology of the detectors as well as the cryocooler and the warm electronics. Then we focus on the performances of the integrated focal planes (responsivity, NEP, low frequency noise, bandwidth).
△ Less
Submitted 26 June, 2006;
originally announced June 2006.
-
A study on the use of the PACS bolometer arrays for submillimeter ground-based telescopes
Authors:
Vincent Reveret,
Louis R. Rodriguez,
Philippe Andre,
Benoit Horeau,
Jean Le Pennec,
Patrick Agnese
Abstract:
A new kind of bolometric architecture has been successfully developed for the PACS photometer onboard the Herschel submillimeter observatory. These new generation CCD-like arrays are buttable and enable the conception of large fully sampled focal planes. We present a feasibility study of the adaptation of these bolometer arrays to ground-based submillimeter telescopes. We have developed an elect…
▽ More
A new kind of bolometric architecture has been successfully developed for the PACS photometer onboard the Herschel submillimeter observatory. These new generation CCD-like arrays are buttable and enable the conception of large fully sampled focal planes. We present a feasibility study of the adaptation of these bolometer arrays to ground-based submillimeter telescopes. We have developed an electro-thermal numerical model to simulate the performances of the bolometers under specific ground-based conditions (different wavelengths and background powers for example). This simulation permits to determine the optimal parameters for each condition and shows that the bolometers can be background limited in each transmission window between 200 and 450 microns. We also present a new optical system that enables to have a maximum absorption of the bolometer in each atmospheric windows. The description of this system and measurements are showed.
△ Less
Submitted 18 June, 2006;
originally announced June 2006.
-
Recent Achievements on the development of the Herschel/PACS Bolometer arrays
Authors:
N. Billot,
P. Agnese,
O. Boulade,
C. Cigna,
E. Doumeyrou,
B. Horeau,
J. Lepennec,
J. Martignac,
J. -L. Pornin,
V. Reveret,
L. Rodriguez,
M. Sauvage,
F. Simoens,
L. Vigroux
Abstract:
A new type of bolometer arrays sensitive in the Far Infrared and Submillimeter range has been developped and manufactured by CEA/LETI/SLIR and will be integrated in the PACS instrument onboard the Herschel Space Observatory (launch date 2008). The main innovations are their collective manufacturing technique (production of 3-side buttable 16x16 arrays) and their high map** efficiency (large fo…
▽ More
A new type of bolometer arrays sensitive in the Far Infrared and Submillimeter range has been developped and manufactured by CEA/LETI/SLIR and will be integrated in the PACS instrument onboard the Herschel Space Observatory (launch date 2008). The main innovations are their collective manufacturing technique (production of 3-side buttable 16x16 arrays) and their high map** efficiency (large format detector and instantaneous Nyquist sampling). Their measured NEP is 2x10^-16 W/Hz^-0.5 and their thermometric passband about 4-5 Hz. In this paper we describe CEA bolometers and present the results obtained during the last test campaign.
△ Less
Submitted 3 March, 2006;
originally announced March 2006.