Skip to main content

Showing 1–15 of 15 results for author: Agarwala, J

.
  1. arXiv:2305.09649  [pdf, other

    physics.ins-det hep-ex

    Exposing a fibre-based dual-readout calorimeter to a positron beam

    Authors: N. Ampilogov, S. Cometti, J. Agarwala, V. Chmill, R. Ferrari, G. Gaudio, P. Giacomelli, A. Giaz, A. Karadzhinova-Ferrer, A. Loeschcke-Centeno, A. Negri, L. Pezzotti, G. Polesello, E. Proserpio, A. Ribon, R. Santoro, I. Vivarelli

    Abstract: A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of the test was to characterise the performance of the tube-based detector response to positrons in terms of linearity, energy resolution, and lateral granularity… ▽ More

    Submitted 18 September, 2023; v1 submitted 16 May, 2023; originally announced May 2023.

    Comments: 23 pages, 18 figures

  2. MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond

    Authors: J. Agarwala, M. Alexeev, C. D. R. Azevedo, F. Bradamante, A. Bressan, M. Buchele, C. Chatterjee, M. Chiosso, A. Cicuttin, P. Ciliberti, M. L. Crespo, S. Dalla Torre, S. Dasgupta, O. Denisov, M. Finger, M. Finger Jr, H. Fischer, L. García Ordóñez, M. Gregori, G. Hamar, F. Herrmann, S. Levorato, A. Martin, G. Menon, D. Panzieri , et al. (7 additional authors not shown)

    Abstract: COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly de… ▽ More

    Submitted 18 June, 2020; originally announced June 2020.

    Comments: 11 Pages; 9 Figures; 8 Sections including References; 18 References; Proceedings for INSTR20 conference accepted in JINST for publication

  3. Contribution of exclusive diffractive processes to the measured azimuthal asymmetries in SIDIS

    Authors: J. Agarwala, M. G. Alexeev, G. D. Alexeev, A. Amoroso, V. Andrieux, N. V. Anfimov, V. Anosov, A. Antoshkin, K. Augsten, W. Augustyniak, C. D. R. Azevedo, B. Badelek, F. Balestra, M. Ball, J. Barth, R. Beck, Y. Bedfer, J. Berenguer Antequera, J. Bernhard, M. Bodlak, P. Bordalo, F. Bradamante, A. Bressan, M. Buechele, V. E. Burtsev , et al. (182 additional authors not shown)

    Abstract: Hadron leptoproduction in Semi-Inclusive measurements of Deep-Inelastic Scattering (SIDIS) on unpolarised nucleons allows one to get information on the intrinsic transverse momentum of quarks in a nucleon and on the Boer-Mulders function through the measurement of azimuthal modulations in the cross section. These modulations were recently measured by the HERMES experiment at DESY on proton and deu… ▽ More

    Submitted 21 December, 2019; originally announced December 2019.

    Comments: 13 pages, 7 figures

    Report number: CERN-EP-2019-286

  4. arXiv:1908.05052  [pdf, other

    physics.ins-det hep-ex

    A modular mini-pad photon detector prototype for RICH application at the Electron Ion Collider

    Authors: J. Agarwala, C. D. R. Azevedo, C. Chatterjee, A. Cicuttin, P. Ciliberti, M. L. Crespo, S. DallaTorre, S. Dasgupta, M. Gregori, G. Hamar, S. Levorato, G. Menon, F. Tessarotto, Y. X. Zhao

    Abstract: Experiments at the future Electron Ion Collider require excellent hadron identification in a broad momentum range, in harsh conditions. A RICH capable to fulfill the PID requirements of the EIC could use MPGD-based photon detectors with solid photocathodes for covering large surfaces at affordable cost, providing good efficiency, high resolution and compatibility with magnetic field. Photon detect… ▽ More

    Submitted 14 August, 2019; originally announced August 2019.

  5. arXiv:1907.10482  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1

    Authors: J. Agarwala, M. Alexeev, C. D. R. Azevedo, F. Bradamante, A. Bressan, M. Buchele, M. Chiosso, C. Chatterjee, P. Ciliberti, S. Dalla Torre, S. Dasgupta, O. Denisov, M. Finger, M. Finger Jr, H. Fischer, M. Gregori, G. Hamar, F. Herrmann, S. Levorato, A. Martin, G. Menon, D. Panzieri, G. Sbrizzai, S. Schopferer, M. Slunecka , et al. (4 additional authors not shown)

    Abstract: After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m… ▽ More

    Submitted 20 July, 2019; originally announced July 2019.

    Comments: MPGD2019 proceedings, presented by Silvia Dalla Torre. arXiv admin note: substantial text overlap with arXiv:1807.00816

  6. arXiv:1907.02385  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1

    Authors: J. Agarwala, M. Bari, F. Bradamante, A. Bressan, C. Chatterjee, A. Cicuttin, P. Ciliberti, M. Crespo, S. Dalla Torre, S. Dasgupta, B. Gobbo, M. Gregori, G. Hamar, S. Levorato, A. Martin, G. Menon, L. B. Rizzuto, Triloki, F. Tessarotto, Y. X. Zhao

    Abstract: The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick… ▽ More

    Submitted 4 July, 2019; originally announced July 2019.

    Comments: 21 pages, NIM.A paper

  7. arXiv:1812.06971  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The Hybrid MPGD-based photon detectors of COMPASS RICH-1

    Authors: J. Agarwala, M. Alexeev, C. D. R. Azevedo, F. Bradamante, A. Bressan, M. Buechele, C. Chatterjee, M. Chiosso, A. Cicuttin, P. Ciliberti, M. L. Crespo, S. Dalla Torre, S. Dasgupta, O. Denisov, M. Finger, M. Finger Jr., H. Fischer, M. Gregori, G. Hamar, F. Herrmann, S. Levorato, A. Martin, G. Menon, D. Panzieri, G. Sbrizzai , et al. (6 additional authors not shown)

    Abstract: Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution o… ▽ More

    Submitted 17 December, 2018; originally announced December 2018.

    Comments: Proceedings of RICH 2018 Workshop

    Journal ref: Nucl. Instr. Methods A 2018

  8. arXiv:1812.04552  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Study of MicroPattern Gaseous detectors with novel nanodiamond based photocathodes for single photon detection in EIC RICH

    Authors: J. Agarwala, C. Chatterjee, G. Cicala, A. Cicuttin, P. Ciliberti, M. L. Crespo, S. Dalla Torre, S. Dasgupta, M. Gregori, S. Levorato, G. Menon, F. Tessarotto, A. Valentini, L. Velardi, Y. Zhao

    Abstract: Identification of high momentum hadrons at the future EIC is crucial, gaseous RICH detectors are therefore viable option. Compact collider setups impose to construct RICHes with small radiator length, hence significantly limiting the number of detected photons. More photons can be detected in the far UV region, using a windowless RICH approach. QE of CsI degrades under strong irradiation and air c… ▽ More

    Submitted 18 March, 2019; v1 submitted 11 December, 2018; originally announced December 2018.

    Comments: 3 pages, 5 figures, RICH2018 conference proceeding

    Journal ref: Nuclear Inst. and Methods in Physics Research, A 952 (2020) 161967

  9. arXiv:1807.01897  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Optimized MPGD-based Photon Detectors for high momentum particle identification at the Electron-Ion Collider

    Authors: J. Agarwala, F. Bradamante, A. Bressan, C. Chatterjee, P. Ciliberti, S. Dalla Torre, S. Dasgupta, M. Gregori, S. Levorato, A. Martin, G. Menon, F. Tessarotto, Y. Zhao

    Abstract: Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the radiator region available at a collider experiment. By selecting a photon wavelength range in the far UV domain, around 120 nm, the number of detectable photons… ▽ More

    Submitted 5 July, 2018; originally announced July 2018.

    Comments: Proceedings for PM2018- 14th Pisa Meeting on Advanced Detectors

  10. arXiv:1807.00816  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond

    Authors: J. Agarwala, M. Alexeev, C. D. R. Azevedo, F. Bradamante, A. Bressan, M. Buchele, M. Chiosso, C. Chatterjee, P. Ciliberti, S. Dalla Torre, S. Dasgupta, O. Denisov, M. Finger, M. Finger Jr, H. Fischer, M. Gregori, G. Hamar, F. Herrmann, S. Levorato, A. Martin, G. Menon, D. Panzieri, G. Sbrizzai, S. Schopferer, M. Slunecka , et al. (4 additional authors not shown)

    Abstract: After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m… ▽ More

    Submitted 2 July, 2018; originally announced July 2018.

    Comments: Proceedings for PM18-14th Pisa meeting on Advanced Detectors (presentation by Silvia Dalla Torre)

  11. arXiv:1804.05765  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The novel photon detectors based on MPGD technologies for the upgrade of COMPASS RICH-1

    Authors: J. Agarwala, M. Alexeev, C. D. R. Azevedo, R. Birsa, F. Bradamante, A. Bressan, C. Chatterjee, M. Chiosso, A. Cicuttin, P. Ciliberti, M. L. Crespo, S. Dalla Torre, S. S. Dasgupta, O. Denisov, M. Finger, M. Finger Jr., B. Gobbo, M. Gregori, G. Hamar, S. Levorato, A. Maggiora, A. Martin, G. Menon, J. Novy, D. Panzieri , et al. (10 additional authors not shown)

    Abstract: The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously used MWPC-based photon detectors. The new detector architecture, resulting from a dedicated, eight years long, R\&D program, consists in a hybrid MPGD combination… ▽ More

    Submitted 16 April, 2018; originally announced April 2018.

    Comments: 5th International Conference on Micro-Pattern Gas Detectors (MPGD2017), speaker: F.Tessarotto (INFN -Trieste)

  12. arXiv:1803.01667  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The high voltage system for the novel MPGD-based photon detectors of COMPASS RICH-1

    Authors: J. Agarwala, R. Birsa, F. Bradamante, A. Bressan, C. Chatterjee, P. Ciliberti, S. Dalla Torre, S. Dasgupta, B. Gobbo, M. Gregori, G. Hamar, S. Levorato, A. Martin, G. Menon, F. Tessarotto, Y. Zhao

    Abstract: The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk resistive MICROMEGAS. Concerning biasing voltage, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MICROMEGAS anode is segmented in pads individually biased at… ▽ More

    Submitted 5 March, 2018; originally announced March 2018.

    Comments: 5th international conference on Micro-Pattern Gas Detectors (MPGD2017),presentation by Silvia Dalla Torre

  13. Multiplicities of charged kaons from deep-inelastic muon scattering off an isoscalar target

    Authors: C. Adolph, J. Agarwala, M. Aghasyan, R. Akhunzyanov, M. G. Alexeev, G. D. Alexeev, A. Amoroso, V. Andrieux, N. V. Anfimov, V. Anosov, K. Augsten, W. Augustyniak, A. Austregesilo, C. D. R. Azevedo, B. Badelek, F. Balestra, M. Ball, J. Barth, R. Beck, Y. Bedfer, J. Bernhard, K. Bicker, E. R. Bielert, R. Birsa, M. Bodlak , et al. (202 additional authors not shown)

    Abstract: Precise measurements of charged-kaon multiplicities in deep inelastic scattering were performed. The results are presented in three-dimensional bins of the Bjorken scaling variable x, the relative virtual-photon energy y, and the fraction z of the virtual-photon energy carried by the produced hadron. The data were obtained by the COMPASS Collaboration by scattering 160 GeV muons off an isoscalar 6… ▽ More

    Submitted 24 August, 2016; originally announced August 2016.

    Comments: 10 pages, 9 figures

    Report number: CERN-EP-2016--206

  14. Exclusive $ω$ meson muoproduction on transversely polarised protons

    Authors: C. Adolph, J. Agarwala, M. Aghasyan, R. Akhunzyanov, M. G. Alexeev, G. D. Alexeev, A. Amoroso, V. Andrieux, N. V. Anfimov, V. Anosov, W. Augustyniak, A. Austregesilo, C. D. R. Azevedo, B. Badelek, F. Balestra, J. Barth, R. Beck, Y. Bedfer, J. Bernhard, K. Bicker, E. R. Bielert, R. Birsa, J. Bisplinghoff, M. Bodlak, M. Boer , et al. (204 additional authors not shown)

    Abstract: Exclusive production of $ω$ mesons was studied at the COMPASS experiment by scattering $160~\mathrm{GeV}/\mathit{c}$ muons off transversely polarised protons. Five single-spin and three double-spin azimuthal asymmetries were measured in the range of photon virtuality $1~(\mathrm{GeV}/\mathit{c})^2 < Q^2 < 10~(\mathrm{GeV}/\mathit{c})^2$, Bjorken scaling variable $0.003 < x_{\mathit{Bj}} < 0.3$ and… ▽ More

    Submitted 18 October, 2017; v1 submitted 12 June, 2016; originally announced June 2016.

    Comments: 23 pages, 9 figures

    Report number: CERN-EP-2016-157

  15. Multiplicities of charged pions and unidentified charged hadrons from deep-inelastic scattering of muons off an isoscalar target

    Authors: C. Adolph, J. Agarwala, M. Aghasyan, R. Akhunzyanov, M. G. Alexeev, G. D. Alexeev, A. Amoroso, V. Andrieux, N. V. Anfimov, V. Anosov, W. Augustyniak, A. Austregesilo, C. D. R. Azevedo, B. Badelek, F. Balestra, J. Barth, R. Beck, Y. Bedfer, J. Bernhard, K. Bicker, E. R. Bielert, R. Birsa, J. Bisplinghoff, M. Bodlak, M. Boer , et al. (203 additional authors not shown)

    Abstract: Multiplicities of charged pions and unidentified hadrons produced in deep-inelastic scattering were measured in bins of the Bjorken scaling variable $x$, the relative virtual-photon energy $y$ and the relative hadron energy $z$. Data were obtained by the COMPASS Collaboration using a 160 GeV muon beam and an isoscalar target ($^6$LiD). They cover the kinematic domain in the photon virtuality… ▽ More

    Submitted 29 April, 2016; v1 submitted 10 April, 2016; originally announced April 2016.

    Report number: CERN-EP-2016-095