Discrete Fourier Transform Method for Discrimination of Digital Scintillation Pulses in Mixed Neutron-Gamma Fields
Authors:
M. J. Safari,
F. Abbasi Davani,
H. Afarideh,
S. Jamili,
E. Bayat
Abstract:
A Discrete Fourier Transform Method (DFTM) for discrimination between the signal of neutrons and gamma rays in organic scintillation detectors is presented. The method is based on the transformation of signals into the frequency domain using the sine and cosine Fourier transforms in combination with the discrete Fourier transform. The method is largely benefited from considerable differences that…
▽ More
A Discrete Fourier Transform Method (DFTM) for discrimination between the signal of neutrons and gamma rays in organic scintillation detectors is presented. The method is based on the transformation of signals into the frequency domain using the sine and cosine Fourier transforms in combination with the discrete Fourier transform. The method is largely benefited from considerable differences that usually is available between the zero-frequency components of sine and cosine and the norm of the amplitude of the DFT for neutrons and gamma-ray signals. Moreover, working in frequency domain naturally results in considerable suppression of the unwanted effects of various noise sources that is expected to be effective in time domain methods. The proposed method could also be assumed as a generalized nonlinear weighting method that could result in a new class of pulse shape discrimination methods, beyond definition of the DFT. A comparison to the traditional Charge Integration Method (CIM), as well as the Frequency Gradient Analysis Method (FGAM) and the Wavelet Packet Transform Method (WPTM) has been presented to demonstrate the applicability and efficiency of the method for real-world applications. The method, in general, shows better discrimination Figure of Merits (FoMs) at both the low-light outputs and in average over the studied energy domain. A noise analysis has been performed for all of the abovementioned methods. It reveals that the frequency domain methods (FGAM and DFTM) are less sensitive to the noise effects.
△ Less
Submitted 1 November, 2016;
originally announced November 2016.
-
Differentiation method for localization of Compton edge in organic scintillation detectors
Authors:
M. J. Safari,
F. Abbasi Davani,
H. Afarideh
Abstract:
This paper, presents a simple method for accurate calibration of organic scintillation detectors. The method is based on the fact that differentiating the response function leads to accurate estimation of the Compton edge. The differentiation method in addition to the location of the Compton edge, gives insights into the parameters of the folded Gaussian function which is useful for determination…
▽ More
This paper, presents a simple method for accurate calibration of organic scintillation detectors. The method is based on the fact that differentiating the response function leads to accurate estimation of the Compton edge. The differentiation method in addition to the location of the Compton edge, gives insights into the parameters of the folded Gaussian function which is useful for determination of the energy resolution. Moreover, it is observed that the uncorrelated noise in the measurement of the response function does not impose significant uncertainties in the evaluations. By simulation of the bounded electrons and considering the Doppler effects, we are able to calculate a first estimation for the intrinsic Doppler resolution of a plastic scintillator, benefiting from the capability of the differentiation method.
△ Less
Submitted 25 November, 2016; v1 submitted 28 October, 2016;
originally announced October 2016.
-
Intelligent Low-level RF System by Non-destructive Beam Monitoring Device for Cyclotrons
Authors:
M. S. Sharifi Asadi Malafeh,
M. Ghergherehchi,
H. Afarideh,
J. S. Chai
Abstract:
The project of a10MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work Intelligent Low Level Radio Frequency Circuit or ILLRF suitable for Most of the AVF cyclotron acce…
▽ More
The project of a10MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work Intelligent Low Level Radio Frequency Circuit or ILLRF suitable for Most of the AVF cyclotron accelerators was designed by the beam monitoring device and narrow band tunable band-pass filter. In this design, for the RF phase detection does not need to signal processing by microcontroller
△ Less
Submitted 20 April, 2015;
originally announced April 2015.
-
Optimization and numerical simulation for the accelerator of the commercial H- cyclotron ion source
Authors:
Maryam Hosseinzadeh,
Hossein Afarideh
Abstract:
A new ion source will be prepared for the CYCLONE30 commercial cyclotron with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency without deteriorating the beam optics, which is designed to deliver an H- beam at 30 keV. The plasma generator of the ion source is of an axially cusped bucket type, and the whole inner wall, except the…
▽ More
A new ion source will be prepared for the CYCLONE30 commercial cyclotron with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency without deteriorating the beam optics, which is designed to deliver an H- beam at 30 keV. The plasma generator of the ion source is of an axially cusped bucket type, and the whole inner wall, except the cathode filaments and plasma electrode side, functions as an anode. The accelerator assembly consists of three circular aperture electrodes made of copper. The simulation study was focused on finding parameter sets that raise the percent of beam transmitted as large as possible and reduces the beam divergence as low as possible. From the simulation results, it was concluded that it is possible to achieve this goal by sliming the plasma electrode (G1), shortening the first gap (G1-G2), and adjusting the G2 voltage.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.