-
A clock with $8\times10^{-19}$ systematic uncertainty
Authors:
Alexander Aeppli,
Kyungtae Kim,
William Warfield,
Marianna S. Safronova,
Jun Ye
Abstract:
We report an optical lattice clock with a total systematic uncertainty of $8.1 \times 10^{-19}$ in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultra-narrow ${}^1S_0 \rightarrow {}^3P_0$ transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattic…
▽ More
We report an optical lattice clock with a total systematic uncertainty of $8.1 \times 10^{-19}$ in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultra-narrow ${}^1S_0 \rightarrow {}^3P_0$ transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the $5s4d$ $^3D_1$ lifetime, necessitating precise characterization and control of many body effects in the $5s4d$ $^3D_1$ decay. Lastly, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below $1 \times 10^{-19}$.
△ Less
Submitted 8 June, 2024; v1 submitted 15 March, 2024;
originally announced March 2024.
-
Evaluation of lattice light shift at low 10$^{-19}$ uncertainty for a shallow lattice Sr optical clock
Authors:
Kyungtae Kim,
Alexander Aeppli,
Tobias Bothwell,
Jun Ye
Abstract:
A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar con…
▽ More
A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5$\times$10${}^{-19}$.
△ Less
Submitted 24 February, 2023; v1 submitted 28 October, 2022;
originally announced October 2022.
-
Hamiltonian engineering of spin-orbit coupled fermions in a Wannier-Stark optical lattice clock
Authors:
Alexander Aeppli,
Anjun Chu,
Tobias Bothwell,
Colin J. Kennedy,
Dhruv Kedar,
Peiru He,
Ana Maria Rey,
Jun Ye
Abstract:
Engineering a Hamiltonian system with tunable interactions provides opportunities to optimize performance for quantum sensing and explore emerging phenomena of many-body systems. An optical lattice clock based on partially delocalized Wannier-Stark states in a gravity-tilted shallow lattice supports superior quantum coherence and adjustable interactions via spin-orbit coupling, thus presenting a p…
▽ More
Engineering a Hamiltonian system with tunable interactions provides opportunities to optimize performance for quantum sensing and explore emerging phenomena of many-body systems. An optical lattice clock based on partially delocalized Wannier-Stark states in a gravity-tilted shallow lattice supports superior quantum coherence and adjustable interactions via spin-orbit coupling, thus presenting a powerful spin model realization. The relative strength of the on-site and off-site interactions can be tuned to achieve a zero density shift at a `magic' lattice depth. This mechanism, together with a large number of atoms, enables the demonstration of the most stable atomic clock while minimizing a key systematic uncertainty related to atomic density. Interactions can also be maximized by driving off-site Wannier-Stark transitions, realizing a ferromagnetic to paramagnetic dynamical phase transition.
△ Less
Submitted 15 January, 2022;
originally announced January 2022.
-
Resolving the gravitational redshift within a millimeter atomic sample
Authors:
Tobias Bothwell,
Colin J. Kennedy,
Alexander Aeppli,
Dhruv Kedar,
John M. Robinson,
Eric Oelker,
Alexander Staron,
Jun Ye
Abstract:
Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and q…
▽ More
Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and quantum mechanics once they become sensitive to the finite wavefunction of quantum objects oscillating in curved spacetime. Towards this regime, we measure a linear frequency gradient consistent with the gravitational redshift within a single millimeter scale sample of ultracold strontium. Our result is enabled by improving the fractional frequency measurement uncertainty by more than a factor of 10, now reaching 7.6$\times 10^{-21}$. This heralds a new regime of clock operation necessitating intra-sample corrections for gravitational perturbations.
△ Less
Submitted 24 September, 2021;
originally announced September 2021.
-
Beyond the Limits of Conventional Stark Deceleration
Authors:
David Reens,
Hao Wu,
Alexander Aeppli,
Anna McAuliffe,
Piotr Wcisło,
Tim Langen,
Jun Ye
Abstract:
Stark deceleration enables the production of cold and dense molecular beams with applications in trap**, collisional studies, and precision measurement. Improving the efficiency of Stark deceleration, and hence the achievable molecular densities, is central to unlock the full potential of such studies. One of the chief limitations arises from the transverse focusing properties of Stark decelerat…
▽ More
Stark deceleration enables the production of cold and dense molecular beams with applications in trap**, collisional studies, and precision measurement. Improving the efficiency of Stark deceleration, and hence the achievable molecular densities, is central to unlock the full potential of such studies. One of the chief limitations arises from the transverse focusing properties of Stark decelerators. We introduce a new operation strategy that circumvents this limit without any hardware modifications, and experimentally verify our results for hydroxyl radicals. Notably, improved focusing results in significant gains in molecule yield with increased operating voltage, formerly limited by transverse-longitudinal coupling. At final velocities sufficiently small for trap**, molecule flux improves by a factor of four, and potentially more with increased voltage. The improvement is more significant for less readily polarized species, thereby expanding the class of candidate molecules for Stark deceleration.
△ Less
Submitted 4 April, 2020;
originally announced April 2020.
-
$T_2$-limited sensing of static magnetic fields via fast rotation of quantum spins
Authors:
A. A. Wood,
A. G. Aeppli,
E. Lilette,
Y. Y. Fein,
A. Stacey,
L. C. L. Hollenberg,
R. E. Scholten,
A. M. Martin
Abstract:
Diamond-based quantum magnetometers are more sensitive to oscillating (AC) magnetic fields than static (DC) fields because the crystal impurity-induced ensemble dephasing time $T_2^*$, the relevant sensing time for a DC field, is much shorter than the spin coherence time $T_2$, which determines the sensitivity to AC fields. Here we demonstrate measurement of DC magnetic fields using a physically r…
▽ More
Diamond-based quantum magnetometers are more sensitive to oscillating (AC) magnetic fields than static (DC) fields because the crystal impurity-induced ensemble dephasing time $T_2^*$, the relevant sensing time for a DC field, is much shorter than the spin coherence time $T_2$, which determines the sensitivity to AC fields. Here we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision ultimately limited by $T_2$ rather than $T_2^*$. The rotation period of the diamond is comparable to $T_2$ and the angle between the NV axis and the target magnetic field changes as a function of time, thus upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry of the rotating NV centres, we are able to perform measurements for over a hundred times longer compared to a conventional Ramsey experiment. With modifications our scheme could realise DC sensitivities equivalent to demonstrated NV center AC magnetic field sensitivities of order $0.1$\,nT\,Hz$^{-1/2}$.
△ Less
Submitted 4 December, 2018; v1 submitted 11 February, 2018;
originally announced February 2018.
-
Unstable particles in One Loop Calculations
Authors:
Andre Aeppli,
Geert Jan van Oldenborgh,
Daniel Wyler
Abstract:
We present a gauge invariant way to compute one loop corrections to processes involving the production and decay of unstable particles.
We present a gauge invariant way to compute one loop corrections to processes involving the production and decay of unstable particles.
△ Less
Submitted 27 April, 1994; v1 submitted 2 December, 1993;
originally announced December 1993.
-
$\order(Γ)$ Corrections to $W$ pair production in $e^+e^-$ and $γγ$ collisions
Authors:
Andre Aeppli,
Frank Cuypers,
Geert Jan van Oldenborgh
Abstract:
Several schemes to introduce finite width effects to reactions involving unstable elementary particles are given and the differences between them are investigated. The effects of the different schemes is investigated numerically for $W$ pair production. In $e^+e^-\to W^+W^-$ we find that the effect of the non-resonant graphs cannot be neglected for $\sqrt{s}\geq400\GeV$. There is no difference b…
▽ More
Several schemes to introduce finite width effects to reactions involving unstable elementary particles are given and the differences between them are investigated. The effects of the different schemes is investigated numerically for $W$ pair production. In $e^+e^-\to W^+W^-$ we find that the effect of the non-resonant graphs cannot be neglected for $\sqrt{s}\geq400\GeV$. There is no difference between the various schemes to add these to the resonant graphs away from threshold, although some violate gauge invariance. On the other hand, in the reaction $γγ\to W^+W^-$ the effect of the non-resonant graphs is large everywhere, due to the $t$-channel pole. However, even requiring that the outgoing lepton is observable ($p_\perp > .02\sqrt{s}$) reduces the contribution to about 1\%. Again, the scheme dependence is negligible here.
△ Less
Submitted 10 March, 1993; v1 submitted 9 March, 1993;
originally announced March 1993.