-
Low-Dose TOF-PET Based on Surface Electron Production in Dielectric Laminar MCPs
Authors:
Kepler Domurat-Sousa,
Cameron Poe,
Henry J. Frisch,
Bernhard W. Adams,
Camden Ertley,
Neal Sullivan
Abstract:
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae…
▽ More
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae containing heavy nuclei such as lead or tungsten (LMCP$^{\rm{TM}}$). The laminae surfaces are micro-patterned to form channels, which can then be functionalized to support secondary electron emission in the manner of conventional MCPs.
We have simulated direct conversion using modifications to the TOPAS Geant4-based tool kit. A 20 $\times$ 20 $\times$ 2.54 cm$^3$ LMCP, composed of 150-micron thick lead-glass laminae, is predicted to have a $\ge 30$% conversion efficiency to a primary electron that penetrates an interior wall of a pore. The subsequent secondary electron shower is largely confined to one pore and can provide high space and time resolutions.
In whole-body PET scanners the technique eliminates the scintillator and photodetector subsystems. The consequent absence of a photocathode allows assembly of large arrays at atmospheric pressure and less stringent vacuum requirements, including use of pumped and cycled systems.
TOPAS simulations of the Derenzo and XCAT-brain phantoms are presented with dose reductions of factors of 100 and 1000 from a literature benchmark. New applications of PET at a significantly lower radiation dose include routine screening for early detection of pathologies, the use in diagnostics in previously unserved patient populations such as children, and a larger installed facility base in rural and under-served populations, where simpler gamma detectors and lower radiation doses may enable small low-cost portable PET scanners.
△ Less
Submitted 18 October, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Surface Direct Conversion of 511 keV Gamma Rays in Large-Area Laminated Multichannel-Plate Electron Multipliers
Authors:
Kepler Domurat-Sousa,
Cameron Poe,
Henry J. Frisch,
Bernhard W. Adams,
Camden Ertley,
Neal Sullivan
Abstract:
We have used the TOPAS simulation framework to model the direct conversion of 511 keV gamma rays to electrons in a micro-channel plate (MCP) constructed from thin laminae of a heavy-metal-loaded dielectric such as lead-glass, patterned with micro-channels (LMCP). The laminae serve as the converter of the gamma ray to a primary electron within a depth from a channel-forming surface such that the el…
▽ More
We have used the TOPAS simulation framework to model the direct conversion of 511 keV gamma rays to electrons in a micro-channel plate (MCP) constructed from thin laminae of a heavy-metal-loaded dielectric such as lead-glass, patterned with micro-channels (LMCP). The laminae serve as the converter of the gamma ray to a primary electron within a depth from a channel-forming surface such that the electron penetrates the channel surface (`surface direct conversion'). The channels are coated with a secondary-emitting material to produce electron multiplication in the channels. The laminae are stacked on edge with the channels running from the top of the resulting `slab' to the bottom; after assembly the slab is metalized top and bottom to form the finished LMCP.
The shape of the perimeter of a lamina determines the dimensions of the slab at the lamina location in the slab, allowing non-uniform cross-sections in slab thickness, width, and length. The slab also can be non-planar, allowing curved surfaces in both lateral dimensions. The laminar construction allows incorporating structural elements in the LMCP for modular assembly in large-area arrays.
The channels can be patterned on the laminae surfaces with internal shapes and structure, texture, and coatings optimized for specific applications and performance. The channels can be non-uniform across the LMCP and need not be parallel in either transverse direction.
Surface direct conversion of the gamma ray to an electron eliminates the common two-step conversion of the gamma ray into an optical photon in a scintillator followed by the conversion of the photon into an electron in a photodetector. The simulations predict an efficiency for conversion of 511 keV gamma rays of $\gtrapprox$ 30\% for a 2.54 cm-thick lead-glass LMCP. The elimination of the photocathode allows assembly at atmospheric pressure.
△ Less
Submitted 21 July, 2023; v1 submitted 20 June, 2023;
originally announced June 2023.
-
Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography
Authors:
Kepler Domurat-Sousa,
Cameron M. Poe,
Maya S. McDaniel,
Eric Spieglan,
Joao F. Shida,
Evan Angelico,
Bernhard W. Adams,
Patrick J. La Riviere,
Henry J. Frisch,
Allison H. Squires
Abstract:
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scatte…
▽ More
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.
△ Less
Submitted 3 January, 2024; v1 submitted 11 May, 2023;
originally announced May 2023.
-
Low-Dose High-Resolution TOF-PET Using Ionization-activated Multi-State Low-Z Detector Media
Authors:
Joao Francisco Shida,
Eric Spieglan,
Bernhard W. Adams,
Evan Angelico,
Kepler Domurat-Sousa,
Andrey Elagin,
Henry J. Frisch,
Patrick La Riviere,
Allison H. Squires
Abstract:
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatter…
▽ More
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a `Switchillator', that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
Air-Transfer Production Method for Large-Area Picosecond Photodetectors
Authors:
E. Angelico,
A. Elagin,
H. J. Frisch,
E. Spieglan,
B. W. Adams,
M. R. Foley,
M. J. Minot
Abstract:
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside th…
▽ More
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and hermetically sealing the large-perimeter window-body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume, and shown that the micro-channel plates recover their functionality after cathode synthesis. The steps inform a design for a multi-module batch facility employing dual nested low-vacuum (LV) and ultra-high-vacuum (UHV) systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.
-
Performance of Large Area Picosecond Photo-Detectors (LAPPD)
Authors:
A. V. Lyashenko,
B. W. Adams,
M. Aviles,
T. Cremer,
C. D. Ertley,
M. R. Foley,
M. J. Minot,
M. A. Popecki,
M. E. Stochaj,
W. A. Worstell,
J. W. Elam,
A. U. Mane,
O. H. W. Siegmund,
H. J. Frisch,
A. L. Elagin,
E. Angelico,
E. Spieglan
Abstract:
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single ph…
▽ More
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25\% or higher in some units) QE uniform bi-alkali photocathodes. LAPPDs is a good candidate to be employed in neutrino experiments (e.g. ANNIE, WATCHMAN, DUNE), particle collider experiments (e.g. EIC), neutrinoless double-beta decay experiments (e.g. THEIA), medical and nuclear non-proliferation applications.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.
-
A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration
Authors:
Bernhard W. Adams,
Klaus Attenkofer,
Mircea Bogdan,
Karen Byrum,
Andrey Elagin,
Jeffrey W. Elam,
Henry J. Frisch,
Jean-Francois Genat,
Herve Grabas,
Joseph Gregar,
Elaine Hahn,
Mary Heintz,
Zinetula Insepov,
Valentin Ivanov,
Sharon Jelinsky,
Slade Jokely,
Sun Wu Lee,
Anil. U. Mane,
Jason McPhate,
Michael J. Minot,
Pavel Murat,
Kurtis Nishimura,
Richard Northrop,
Razib Obaid,
Eric Oberla
, et al. (16 additional authors not shown)
Abstract:
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$,…
▽ More
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.
△ Less
Submitted 6 March, 2016;
originally announced March 2016.
-
Precise Orbital Tracking of an Asteroid with a Phased Array of Radio Transponders
Authors:
Bernhard W. Adams
Abstract:
Deflecting an asteroid from an Earth impact trajectory requires only small velocity changes, typically of the order of microns per second, if done many years ahead of time. For this, a highly precise method of determining the need, magnitude, and direction of a deflection is required. Although the required precision can be achieved by much less accurate extended observations, an intrinsic resolu…
▽ More
Deflecting an asteroid from an Earth impact trajectory requires only small velocity changes, typically of the order of microns per second, if done many years ahead of time. For this, a highly precise method of determining the need, magnitude, and direction of a deflection is required. Although the required precision can be achieved by much less accurate extended observations, an intrinsic resolution of $μ$m/s permits the live monitoring of nongravitational orbital perturbations (Yarkovsky effect), and of a deflection effort itself. Here, it is proposed to deploy on the asteroid's surface multiple radio units to form a phased array capable of measuring radial velocities relative to Earth to about 1 $μ$m/s and ranges to 5 m. The same technology can also be used for scientific applications such as very-long baseline radio astronomy, milli-Hertz gravitational wave detection, or map** of the solar wind.
△ Less
Submitted 15 September, 2008;
originally announced September 2008.