The EBEX Balloon Borne Experiment - Detectors and Readout
Authors:
The EBEX Collaboration,
Maximilian Abitbol,
Asad M. Aboobaker,
Peter Ade,
Derek Araujo,
François Aubin,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Stephen M. Feeney,
Christopher Geach,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Gene Hilton,
Johannes Hubmayr,
Kent Irwin,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Jeff Klein,
Andrei Korotkov
, et al. (15 additional authors not shown)
Abstract:
EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array of transition edge sensor (TES) bolometers aboard a balloon platform; shortly after reaching float we operated 504, 342, and 109 TESs at each of the bands, respectivel…
▽ More
EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array of transition edge sensor (TES) bolometers aboard a balloon platform; shortly after reaching float we operated 504, 342, and 109 TESs at each of the bands, respectively. We describe the design and characterization of the array and the readout system. We give the distributions of measured thermal conductances, normal resistances, and transition temperatures. With the exception of the thermal conductance at 150 GHz. We measured median low-loop-gain time constants $τ_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively. We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the three bands, respectively. EBEX pioneered the use of the digital version of the frequency domain multiplexing (FDM) system which multiplexed the bias and readout of 16 bolometers onto two wires. We present accounting of the measured noise equivalent power. The median per-detector noise equivalent temperatures referred to a black body with a temperature of 2.725 K are 400, 920, and 14500 $μ$K$\sqrt{s}$ for the three bands, respectively. We compare these values to our pre-flight predictions and to a previous balloon payload, discuss the sources of excess noise, and the path for a future payload to make full use of the balloon environment.
△ Less
Submitted 30 July, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Intensity-Coupled-Polarization in Instruments with a Continuously Rotating Half-Wave Plate
Authors:
Joy Didier,
Amber D. Miller,
Derek Araujo,
François Aubin,
Christopher Geach,
Bradley Johnson,
Andrei Korotkov,
Kate Raach,
Benjamin Westbrook,
Karl Young,
Asad M. Aboobaker,
Peter Ade,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Matt Dobbs,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Johannes Hubmayr,
Andrew Jaffe,
Terry Jones,
Jeff Klein,
Adrian Lee
, et al. (9 additional authors not shown)
Abstract:
We discuss a systematic effect associated with measuring polarization with a continuously rotating half-wave plate. The effect was identified with the data from the E and B Experiment (EBEX), which was a balloon-borne instrument designed to measure the polarization of the CMB as well as that from Galactic dust. The data show polarization fraction larger than 10\% while less than 3\% were expected…
▽ More
We discuss a systematic effect associated with measuring polarization with a continuously rotating half-wave plate. The effect was identified with the data from the E and B Experiment (EBEX), which was a balloon-borne instrument designed to measure the polarization of the CMB as well as that from Galactic dust. The data show polarization fraction larger than 10\% while less than 3\% were expected from instrumental polarization. We give evidence that the excess polarization is due to detector non-linearity in the presence of a continuously rotating HWP. The non-linearity couples intensity signals into polarization. We develop a map-based method to remove the excess polarization. Applying this method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess polarization was removed. Characterization and mitigation of this effect is important for future experiments aiming to measure the CMB B-modes with a continuously rotating HWP.
△ Less
Submitted 28 February, 2018; v1 submitted 3 November, 2017;
originally announced November 2017.
-
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
Authors:
The EBEX Collaboration,
Asad M. Aboobaker,
Peter Ade,
Derek Araujo,
François Aubin,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Christopher Geach,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Johannes Hubmayr,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Jeff Klein,
Andrei Korotkov,
Adrian Lee,
Lorne Levinson,
Michele Limon,
Kevin MacDermid
, et al. (13 additional authors not shown)
Abstract:
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background polarimeter that flew over Antarctica in 2013. We describe the experiment's optical system, receiver, and polarimetric approach, and report on their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make efficient use of limited mass and space we designed a 115 cm…
▽ More
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background polarimeter that flew over Antarctica in 2013. We describe the experiment's optical system, receiver, and polarimetric approach, and report on their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make efficient use of limited mass and space we designed a 115 cm$^{2}$sr high throughput optical system that had two ambient temperature mirrors and four anti-reflection coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). Rotation stability was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01 degrees. This is the first use of a SMB in astrophysics. The measured modulation efficiency was above 90 % for all bands. To our knowledge the 109 % fractional bandwidth of the AHWP was the broadest implemented to date. The receiver that contained one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K performed according to specifications giving focal plane temperature stability with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters including high throughput optical systems, and large arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
△ Less
Submitted 30 May, 2017; v1 submitted 10 March, 2017;
originally announced March 2017.
-
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and Control Software
Authors:
The EBEX Collaboration,
Asad Aboobaker,
Peter Ade,
Derek Araujo,
François Aubin,
Carlo Baccigalupi,
Chaoyun Bao,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Johannes Hubmayr,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Jeff Klein,
Andrei Korotkov,
Adrian Lee,
Lorne Levinson,
Michele Limon,
Kevin MacDermid,
Amber D. Miller
, et al. (11 additional authors not shown)
Abstract:
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilo-pixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for rea…
▽ More
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilo-pixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilo-pixel array, and specialized attitude reconstruction software. We present flight performance data showing faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of CMB B-mode power spectrum with $r=0.05$.
△ Less
Submitted 11 April, 2017; v1 submitted 22 February, 2017;
originally announced February 2017.
-
A Double Vacuum Window Mechanism for Space-borne Applications
Authors:
K. Zilic,
A. Aboobaker,
F. Aubin,
C. Geach,
S. Hanany,
N. Jarosik,
M. Milligan,
I. Sagiv
Abstract:
We present a vacuum window mechanism that is useful for applications requiring two different vacuum windows in series, with one of them movable and resealable. Such applications include space borne instruments that can benefit from a thin vacuum window at low ambient pressures, but must also have an optically open aperture at atmospheric pressures. We describe the implementation and successful ope…
▽ More
We present a vacuum window mechanism that is useful for applications requiring two different vacuum windows in series, with one of them movable and resealable. Such applications include space borne instruments that can benefit from a thin vacuum window at low ambient pressures, but must also have an optically open aperture at atmospheric pressures. We describe the implementation and successful operation with the EBEX balloon-borne payload, a millimeter-wave instrument designed to measure the polarization of the cosmic microwave background radiation.
△ Less
Submitted 26 April, 2017; v1 submitted 6 February, 2017;
originally announced February 2017.
-
A high-resolution pointing system for fast scanning platforms: The EBEX example
Authors:
Joy Didier,
Daniel Chapman,
Asad Aboobaker,
Derek Araujo,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Andrei Korotkov,
Michele Limon,
Amber Miller,
Britt Reichborn-Kjennerud,
Ilan Sagiv,
Greg Tucker,
Yuri Vinokurov
Abstract:
The E and B experiment (EBEX) is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background with 8' resolution employing a gondola scanning with speeds of order degree per second. In January 2013, EBEX completed 11 days of observations in a flight over Antarctica covering $\sim$ 6000 square degrees of the sky. The payload is equipped with two redundant star c…
▽ More
The E and B experiment (EBEX) is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background with 8' resolution employing a gondola scanning with speeds of order degree per second. In January 2013, EBEX completed 11 days of observations in a flight over Antarctica covering $\sim$ 6000 square degrees of the sky. The payload is equipped with two redundant star cameras and two sets of three orthogonal gyroscopes to reconstruct the telescope attitude. The EBEX science goals require the pointing to be reconstructed to approximately 10" in the map domain, and in-flight attitude control requires the real time pointing to be accurate to $\sim$ 0.5$^{\circ}$ . The high velocity scan strategy of EBEX coupled to its float altitude only permits the star cameras to take images at scan turnarounds, every $\sim$ 40 seconds, and thus requires the development of a pointing system with low noise gyroscopes and carefully controlled systematic errors. Here we report on the design of the pointing system and on a simulation pipeline developed to understand and minimize the effects of systematic errors. The performance of the system is evaluated using the 2012/2013 flight data, and we show that we achieve a pointing error with RMS=25" on 40 seconds azimuth throws, corresponding to an error of $\sim$ 4.6" in the map domain.
△ Less
Submitted 9 February, 2016;
originally announced February 2016.
-
Temperature calibration of the E and B experiment
Authors:
Francois Aubin,
Asad M. Aboobaker,
Peter Ade,
Derek Araujo,
Carlo Baccigalupi,
Chaoyun Bao,
Julian Borrill,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Stephen Feeney,
Christopher Geach,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Gene Hilton,
Johannes Hubmayr,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Theodore Kisner,
Jeff Klein,
Andrei Korotkov,
Adrian Lee,
Lorne Levinson
, et al. (18 additional authors not shown)
Abstract:
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to measure the polarization of the cosmic microwave background radiation and to characterize the polarization of galactic dust. EBEX was launched December 29, 2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky during 11 days at three frequency bands centered around 150, 250 and 410 GHz. EBEX was the…
▽ More
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to measure the polarization of the cosmic microwave background radiation and to characterize the polarization of galactic dust. EBEX was launched December 29, 2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky during 11 days at three frequency bands centered around 150, 250 and 410 GHz. EBEX was the first experiment to operate a kilo-pixel array of transition-edge sensor bolometers and a continuously rotating achromatic half-wave plate aboard a balloon platform. It also pioneered the use of detector readout based on digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response of the experiment is calibrated using a two-step iterative process. We use signals measured on passes across the Galactic plane to convert from readout-system counts to power. The effective smoothing scale of the EBEX optics and the star camera-to-detector offset angles are determined through \c{hi}2 minimization using the compact HII region RCW 38. This two-step process is initially performed with parameters measured before the EBEX 2013 flight and then repeated until the calibration factor and parameters converge.
△ Less
Submitted 28 January, 2016;
originally announced January 2016.
-
The performance of the bolometer array and readout system during the 2012/2013 flight of the E and B experiment (EBEX)
Authors:
Kevin MacDermid,
Asad M. Aboobaker,
Peter Ade,
Francois Aubin,
Carlo Baccigalupi,
Kevin Bandura,
Chaoyun Bao,
Julian Borrill,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Julien Grain,
Will Grainger,
Shaul Hanany,
Kyle Helson,
Seth Hillbrand,
Gene Hilton,
Hannes Hubmayr,
Kent Irwin,
Bradley Johnson,
Andrew Jaffe,
Terry Jones,
Ted Kisner,
Jeff Klein,
Andrei Korotkov
, et al. (16 additional authors not shown)
Abstract:
EBEX is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background radiation. During its eleven day science flight in the Austral Summer of 2012, it operated 955 spider-web transition edge sensor (TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the first time that an array of TES bolometers has been used on a balloon platform to conduct…
▽ More
EBEX is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background radiation. During its eleven day science flight in the Austral Summer of 2012, it operated 955 spider-web transition edge sensor (TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the first time that an array of TES bolometers has been used on a balloon platform to conduct science observations. Polarization sensitivity was provided by a wire grid and continuously rotating half-wave plate. The balloon implementation of the bolometer array and readout electronics presented unique development requirements. Here we present an outline of the readout system, the remote tuning of the bolometers and Superconducting QUantum Interference Device (SQUID) amplifiers, and preliminary current noise of the bolometer array and readout system.
△ Less
Submitted 22 July, 2014;
originally announced July 2014.
-
EBEX: A balloon-borne CMB polarization experiment
Authors:
Britt Reichborn-Kjennerud,
Asad M. Aboobaker,
Peter Ade,
Françcois Aubin,
Carlo Baccigalupi,
Chaoyun Bao,
Julian Borrill,
Christopher Cantalupo,
Daniel Chapman,
Joy Didier,
Matt Dobbs,
Julien Grain,
William Grainger,
Shaul Hanany,
Seth Hillbrand,
Johannes Hubmayr,
Andrew Jaffe,
Bradley Johnson,
Terry Jones,
Theodore Kisner,
Jeff Klein,
Andrei Korotkov,
Sam Leach,
Adrian Lee,
Lorne Levinson
, et al. (21 additional authors not shown)
Abstract:
EBEX is a NASA-funded balloon-borne experiment designed to measure the polarization of the cosmic microwave background (CMB). Observations will be made using 1432 transition edge sensor (TES) bolometric detectors read out with frequency multiplexed SQuIDs. EBEX will observe in three frequency bands centered at 150, 250, and 410 GHz, with 768, 384, and 280 detectors in each band, respectively. This…
▽ More
EBEX is a NASA-funded balloon-borne experiment designed to measure the polarization of the cosmic microwave background (CMB). Observations will be made using 1432 transition edge sensor (TES) bolometric detectors read out with frequency multiplexed SQuIDs. EBEX will observe in three frequency bands centered at 150, 250, and 410 GHz, with 768, 384, and 280 detectors in each band, respectively. This broad frequency coverage is designed to provide valuable information about polarized foreground signals from dust. The polarized sky signals will be modulated with an achromatic half wave plate (AHWP) rotating on a superconducting magnetic bearing (SMB) and analyzed with a fixed wire grid polarizer. EBEX will observe a patch covering ~1% of the sky with 8' resolution, allowing for observation of the angular power spectrum from \ell = 20 to 1000. This will allow EBEX to search for both the primordial B-mode signal predicted by inflation and the anticipated lensing B-mode signal. Calculations to predict EBEX constraints on r using expected noise levels show that, for a likelihood centered around zero and with negligible foregrounds, 99% of the area falls below r = 0.035. This value increases by a factor of 1.6 after a process of foreground subtraction. This estimate does not include systematic uncertainties. An engineering flight was launched in June, 2009, from Ft. Sumner, NM, and the long duration science flight in Antarctica is planned for 2011. These proceedings describe the EBEX instrument and the North American engineering flight.
△ Less
Submitted 21 July, 2010;
originally announced July 2010.
-
The EBEX Cryostat and Supporting Electronics
Authors:
Ilan Sagiv,
Asad M. Aboobaker,
Chaoyun Bao,
Shaul Hanany,
Terry Jones,
Jeffrey Klein,
Michael Milligan,
Daniel E. Polsgrove,
Kate Raach,
Kyle Zilic,
Andrei Korotkov,
Gregory S. Tucker,
Yuri Vinukurov,
Tomotake Matsumura,
Peter Ade,
Will Grainger,
Enzo Pascale,
Daniel Chapman,
Joy Didier,
Seth Hillbrand,
Britt Reichborn-Kjennerud,
Michele Limon,
Amber Miller,
Andrew Jaffe,
Amit Yadav
, et al. (19 additional authors not shown)
Abstract:
We describe the cryostat and supporting electronics for the EBEX experiment. EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization of the cosmic microwave background radiation. The instrument includes a 1.5 meter Gregorian-type telescope and 1432 bolometric transition edge sensor detectors operating at 0.3 K. Electronics for monitoring temperatures and controlling cryosta…
▽ More
We describe the cryostat and supporting electronics for the EBEX experiment. EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization of the cosmic microwave background radiation. The instrument includes a 1.5 meter Gregorian-type telescope and 1432 bolometric transition edge sensor detectors operating at 0.3 K. Electronics for monitoring temperatures and controlling cryostat refrigerators is read out over CANbus. A timing system ensures the data from all subsystems is accurately synchronized. EBEX completed an engineering test flight in June 2009 during which the cryogenics and supporting electronics performed according to predictions. The temperatures of the cryostat were stable, and an analysis of a subset of the data finds no scan synchronous signal in the cryostat temperatures. Preparations are underway for an Antarctic flight.
△ Less
Submitted 18 May, 2010;
originally announced May 2010.
-
Optical Design of the Atacama Cosmology Telescope and the Millimeter Bolometric Array Camera
Authors:
J. W. Fowler,
M. D. Niemack,
S. R. Dicker,
A. M. Aboobaker,
P. A. R. Ade,
E. S. Battistelli,
M. J. Devlin,
R. P. Fisher,
M. Halpern,
P. C. Hargrave,
A. D. Hincks,
M. Kaul,
J. Klein,
J. M. Lau,
M. Limon,
T. A. Marriage,
P. D. Mauskopf,
L. Page,
S. T. Staggs,
D. S. Swetz,
E. R. Switzer,
R. J. Thornton,
C. E. Tucker
Abstract:
The Atacama Cosmology Telescope is a 6-meter telescope designed to map the Cosmic Microwave Background simultaneously at 145 GHz, 215 GHz, and 280 GHz with arcminute resolution. Each frequency will have a 32 by 32 element focal plane array of TES bolometers. This paper describes the design of the telescope and the cold reimaging optics, which is optimized for millimeter-wave observations with th…
▽ More
The Atacama Cosmology Telescope is a 6-meter telescope designed to map the Cosmic Microwave Background simultaneously at 145 GHz, 215 GHz, and 280 GHz with arcminute resolution. Each frequency will have a 32 by 32 element focal plane array of TES bolometers. This paper describes the design of the telescope and the cold reimaging optics, which is optimized for millimeter-wave observations with these sensitive detectors.
△ Less
Submitted 2 February, 2007; v1 submitted 31 December, 2006;
originally announced January 2007.
-
CMB Observations with a Compact Heterogeneous 150 GHz Interferometer in Chile
Authors:
J. W. Fowler,
W. B. Doriese,
T. A. Marriage,
H. T. Tran,
A. M. Aboobaker,
C. Dumont,
M. Halpern,
Z. D. Kermish,
Y. -S. Loh,
L. A. Page,
S. T. Staggs,
D. H. Wesley
Abstract:
We report on the design, first observing season, and analysis of data from a new prototype millimeter-wave interferometer, MINT. MINT consists of four 145 GHz SIS mixers operating in double-sideband mode in a compact heterogeneous configuration. The signal band is subdivided by a monolithic channelizer, after which the correlations between antennas are performed digitally. The typical receiver s…
▽ More
We report on the design, first observing season, and analysis of data from a new prototype millimeter-wave interferometer, MINT. MINT consists of four 145 GHz SIS mixers operating in double-sideband mode in a compact heterogeneous configuration. The signal band is subdivided by a monolithic channelizer, after which the correlations between antennas are performed digitally. The typical receiver sensitivity in a 2 GHz band is 1.4 mK sqrt(s). MINT observed the cosmic microwave background (CMB) from the Chilean Altiplano. The site has a median nighttime atmospheric temperature of 9 K at zenith (exclusive of the CMB). Observations of Mars, Jupiter, and a telescope-mounted calibration source establish the system's phase and magnitude stability. MINT is the first CMB-dedicated interferometer to operate above 50 GHz. The same type of system can be used to probe the Sunyaev-Zel'dovich effect in galaxy clusters near the SZ null at 217 GHz. We present an analysis of sideband-separated, digitally sampled data recorded by the array. Based on 215 hours of data taken in late 2001, we set an upper limit on the CMB anisotropy in a band of width Delta ell=700 around ell=1540 of delta T < 105 microK (95% conf). Increased sensitivity can be achieved with more integration time, greater bandwidth, and more elements.
△ Less
Submitted 27 January, 2005; v1 submitted 5 March, 2004;
originally announced March 2004.