Experiments towards resolving the proton charge radius puzzle
Authors:
A. Antognini,
K. Schuhmann,
F. D. Amaro,
P. Amaro,
M. Abdou-Ahmed,
F. Biraben,
T. -L. Chen,
D. S. Covita,
A. J. Dax,
M. Diepold,
L. M. P. Fernandes,
B. Franke,
S. Galtier,
A. L. Gouvea,
J. Götzfried,
T. Graf,
T. W. Hänsch,
M. Hildebrandt,
P. Indelicato,
L. Julien,
K. Kirch,
A. Knecht,
F. Kottmann,
J. J. Krauth,
Y. -W. Liu
, et al. (12 additional authors not shown)
Abstract:
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.
△ Less
Submitted 17 October, 2015; v1 submitted 10 September, 2015;
originally announced September 2015.
Improved X-ray detection and particle identification with avalanche photodiodes
Authors:
Marc Diepold,
Luis M. P. Fernandes,
Jorge Machado,
Pedro Amaro,
Marwan Abdou-Ahmed,
Fernando D. Amaro,
Aldo Antognini,
François Biraben,
Tzu-Ling Chen,
Daniel S. Covita,
Andreas J. Dax,
Beatrice Franke,
Sandrine Galtier,
Andrea L. Gouvea,
Johannes Götzfried,
Thomas Graf,
Theodor W. Hänsch,
Malte Hildebrandt,
Paul Indelicato,
Lucile Julien,
Klaus Kirch,
Andreas Knecht,
Franz Kottmann,
Julian J. Krauth,
Yi-Wei Liu
, et al. (14 additional authors not shown)
Abstract:
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to acco…
▽ More
Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g. to distinguish between x-rays and MeV electrons in our experiment.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.