Skip to main content

Showing 1–9 of 9 results for author: Abbon, P

.
  1. Aging effects in the COMPASS hybrid GEM-Micromegas pixelized detectors

    Authors: Damien Neyret, Philippe Abbon, Marc Anfreville, Vincent Andrieux, Yann Bedfer, Dominique Durand, Sébastien Herlant, Nicole d'Hose, Fabienne Kunne, Stephane Platchkov, Florian Thibaud, Michel Usseglio, Maxence Vandenbroucke

    Abstract: Large-size hybrid and pixelized GEM-Micromegas gaseous detectors (40x40 cm$^2$ active area) were developed and installed in 2014 and 2015 for the COMPASS2 physics program which started at the same time. That program involved in particular two full years of Drell-Yan studies using a high-intensity pion beam on a thick polarized target. Although the detectors were placed behind a thick absorber, the… ▽ More

    Submitted 20 June, 2024; v1 submitted 28 February, 2024; originally announced February 2024.

    Comments: 9 pages, 9 figures, proceedings to the 3rd International Conference on Detector Stability and Aging Phenomena in Gaseous Detectors, CERN, November 6-10 2023, will be published in the NIMA journal Proceedings Section

    Journal ref: Nucl.Instrum.Meth.A 1065 (2024) 169511

  2. Design, operation and performance of the PAON4 prototype transit interferometer

    Authors: R. Ansari, J. E Campagne, D. Charlet, M. Moniez, C. Pailler, O. Perdereau, M. Taurigna, J. M. Martin, F. Rigaud, P. Colom, Ph. Abbon, Ch. Magneville, J. Pezzani, C. Viou, S. A. Torchinsky, Q. Huang, J. Zhang

    Abstract: PAON4 is an L-band (1250-1500 MHz) small interferometer operating in transit mode deployed at the Nançay observatory in France, designed as a prototype instrument for Intensity Map**. It features four 5~meter diameter dishes in a compact triangular configuration, with a total geometric collecting area of $\sim75 \mathrm{m^2}$, and equipped with dual polarization receivers. A total of 36 visibili… ▽ More

    Submitted 8 February, 2020; v1 submitted 17 October, 2019; originally announced October 2019.

    Comments: 17 pages, 16 figures, accepted to MNRAS

  3. Fast and Efficient Detection of 511 keV Photons using Cherenkov Light in PbF$_2$ Crystal coupled to a MCP-PMT and SAMPIC Digitization Module

    Authors: C. Canot, M. Alokhina, P. Abbon, J. P. Bard, D. Breton, E. Delagnes, J. Maalmi, G. Tauzin, D. Yvon, V. Sharyy

    Abstract: We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT XP85012. Amplified PMT signals are digitized by the SAMPIC module with high readout rate, up to $10^5$ events/s, and a negligible contribution to the time resol… ▽ More

    Submitted 14 November, 2019; v1 submitted 13 September, 2019; originally announced September 2019.

    Comments: Accepted by JINST

    Journal ref: Journal of Instrumentation, 14, P1200 (2019)

  4. arXiv:1410.1797  [pdf, other

    physics.ins-det hep-ex

    The COMPASS Setup for Physics with Hadron Beams

    Authors: Ph. Abbon, C. Adolph, R. Akhunzyanov, Yu. Alexandrov, M. G. Alexeev, G. D. Alexeev, A. Amoroso, V. Andrieux, V. Anosov, A. Austregesilo, B. Badelek, F. Balestra, J. Barth, G. Baum, R. Beck, Y. Bedfer, A. Berlin, J. Bernhard, K. Bicker, E. R. Bielert, J. Bieling, R. Birsa, J. Bisplinghoff, M. Bodlak, M. Boer , et al. (207 additional authors not shown)

    Abstract: The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well… ▽ More

    Submitted 7 October, 2014; originally announced October 2014.

    Comments: 91 pages, 101 figures and 7 tables

  5. arXiv:1111.3337  [pdf

    physics.ins-det hep-ex

    New pixelized Micromegas detector with low discharge rate for the COMPASS experiment

    Authors: Damien Neyret, Philippe Abbon, Marc Anfreville, Yann Bedfer, Etienne Burtin, Christophe Coquelet, Nicole d'Hose, Daniel Desforge, Arnaud Giganon, Didier Jourde, Fabienne Kunne, Alain Magnon, Nour Makke, Claude Marchand, Bernard Paul, Stéphane Platchkov, Florian Thibaud, Michel Usseglio, Maxence Vandenbroucke

    Abstract: New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than for the present Micr… ▽ More

    Submitted 25 January, 2012; v1 submitted 14 November, 2011; originally announced November 2011.

    Comments: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous Detectors conference (MPGD2011), 29-31 August 2011, Kobe, Japan

  6. arXiv:0902.0444  [pdf, ps, other

    physics.ins-det hep-ex

    Pattern recognition and PID for COMPASS RICH-1

    Authors: P. Abbon, M. Alexeev, H. Angerer, R. Birsa, P. Bordalo, F. Bradamante, A. Bressan, M. Chiosso, P. Ciliberti, M. L. Colantoni, T. Dafni, S. Dalla Torre, E. Delagnes, O. Denisov, H. Deschamps, V. Diaz, N. Dibiase, V. Duic, W. Eyrich, A. Ferrero, M. Finger, M. Finger Jr, H. Fischer, S. Gerassimov, M. Giorgi , et al. (44 additional authors not shown)

    Abstract: A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure… ▽ More

    Submitted 3 February, 2009; originally announced February 2009.

    Comments: 4 pages, 4 figures,to appear in the proceedings of 6th International Workshop on Ring Imaging Cherenkov Counters (RICH 2007), Trieste, Italy, 15-20 Oct 2007

    Journal ref: Nucl.Instrum.Meth.A595:233-236,2008

  7. The COMPASS Experiment at CERN

    Authors: COMPASS Collaboration, P. Abbon

    Abstract: The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are dete… ▽ More

    Submitted 30 March, 2007; originally announced March 2007.

    Comments: 84 papes, 74 figures

    Report number: CERN-PH-EP/2007-001

    Journal ref: Nucl.Instrum.Meth.A577:455-518,2007

  8. The Micromegas detector of the CAST experiment

    Authors: P. Abbon, S. Andriamonje, S. Aune, T. Dafni, M. Davenport, E. Delagnes, R. de Oliveira, G. Fanourakis, E. Ferrer Ribas, J. Franz, T. Geralis, M. Gros, Y. Giomataris, I. G. Irastorza, K. Kousouris, J. Morales, T. Papaevangelou, J. Ruz, K. Zachariadou, K. Zioutas

    Abstract: A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated efficiently and achieved a very low level of background rejection (5 x 10^-5 counts/keV/cm^2/s) without shielding.

    Submitted 22 February, 2007; originally announced February 2007.

    Comments: 13 pages, 12 figures and images, submitted to New Journal of

    Journal ref: NewJ.Phys.9:170,2007

  9. A low background Micromegas detector for the CAST experiment

    Authors: P. Abbon, S. Andriamonje, S. Aune, D. Besin, S. Cazaux, P. Contrepois, T. Dafni, T. Decker, N. Duportail, G. Fanourakis, E. Ferrer Ribas, T. Geralis, A. Giganon, I. Giomataris, M. Gros, R. Hill, I. G. Irastorza, K. Kousouris, J. Morales, M. Pivovaroff, M. Riallot, R. Soufli, K. Zachariadou, G. Zaffanela

    Abstract: A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection ($5\times 10^{-5}$ counts keV$^{-1}$cm$^{-2}$s$^{-1}$) thanks to its good spatial and energy resolution as well as the low radioactivity m… ▽ More

    Submitted 28 October, 2005; originally announced October 2005.

    Comments: 6 pages, 3 figures To appear on the proceedings of the 9th ICATPP Conference on AStroparticle, Particle, Space Physics, Detectors and Medical Physics Applications